Napoleon GrillsメーカーGDS 50-Nの使用説明書/サービス説明書
ページ先へ移動 of 24
1 W415-0098 / A / 08.07.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0098 / A / 08.07.03 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 LOCA TION & CLEARANCES 6-11 DIRECT VENT SPECIFICS MODEL GDS50 V.
3 W415-0098 / A / 08.07.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0098 / A / 08.07.03 FOR YOUR SA TISF ACTION, THIS ST OVE HAS BEEN TEST -FIRED T O ASSURE ITS OPERA TION AND QUAL- ITY! Minimum inlet gas supply pressure is 4.
5 W415-0098 / A / 08.07.03 As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created.
6 W415-0098 / A / 08.07.03 Use only Napoleon or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to.
7 W415-0098 / A / 08.07.03 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * I t i s re c o m m e n d e d t o u s e a h e at s h i e l d a n d t o m a x i m i ze t h e d i s t a n c e t o v i n y l cl a d s o f f i t s.
8 W415-0098 / A / 08.07.03 5 7 " f ir s t r u n 7 2 " s e c o n d r u n 4 8 " Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. FIGURE 8. When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow .
9 W415-0098 / A / 08.07.03 This application occurs when venting through an ex- terior wall. FIGURES 5, 6, & 13. Having deter- mined the air terminal loca- tion, cut and frame a hole in an exterior wall with a mini- mum square or round open- ing of 9".
10 W415-0098 / A / 08.07.03 FIGURE 17 FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA TION OF THE TION OF THE TION OF .
11 W415-0098 / A / 08.07.03 In Canada, mobile home installation may be vented hori- zontally or vertically . In the United St ates, it may only be installed vertically . See "V ertical V enting" or "Horizontal Air T erminal Installation" for inst allation.
12 W415-0098 / A / 08.07.03 Follow the instructions for " Wall and Ceiling Protection". ADAPTER INST ALLA TION FIGURE 27 1. Remove the spill switch bracket from the rear of the adapter . 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches.
13 W415-0098 / A / 08.07.03 Remove nails from the shingles above and to the sides of the chimney . Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around.
14 W415-0098 / A / 08.07.03 Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit. Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.
15 W415-0098 / A / 08.07.03 When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next open both side doors fully . Pull the latch handles towards you and release each catch.
16 W415-0098 / A / 08.07.03 LOG PLACEMENT POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers strips, exclusive to Napoleon Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is dif- ferent in every installation.
17 W415-0098 / A / 08.07.03 Purge all gas lines with the glass door open. Assure that a continuous gas flow is at the burner before closing the door . Allow se veral min utes (5-15) for the flame to stabi- lize after ignition.
18 W415-0098 / A / 08.07.03 5. Turn gas knob counter-clockwise to pilot. 6. Depress slightly and hold gas knob while lighting the pilot with the push button ignitor . Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.
19 W415-0098 / A / 08.07.03 B L O W E R THERMODISC b l a c k g r o u n d VARIABLE SPEED SW ITCH w h i t e FIGURE 44 RELIEF DOOR GASKET RELIEF DOOR TWIN BLOWE FIGURE 45 1. Turn off the electrical power and the gas supply to the stove. 2. Open the lower louvre control door , the two side doors, and the fire viewing door .
20 W415-0098 / A / 08.07.03 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow .
21 W415-0098 / A / 08.07.03 GD175 WALL TERMINAL KIT 44 BM6790 90° ELBOW - 7" DIAMETER 45 GD222 TERMINAL ASSEMBL Y 4 6 BM67ADJ 30" TO 53" ADJUST ABLE PIPE - 7" DIA 4 7 W500-0077 FI.
22 W415-0098 / A / 08.07.03 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
23 W415-0098 / A / 08.07.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed.
24 W415-0098 / A / 08.07.03 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL GDS50 ONL Y) - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection.
デバイスNapoleon Grills GDS 50-Nの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Grills GDS 50-Nをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Grills GDS 50-Nの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Grills GDS 50-Nの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Grills GDS 50-Nで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Grills GDS 50-Nを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Grills GDS 50-Nの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Grills GDS 50-Nに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Grills GDS 50-Nデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。