Napoleon GrillsメーカーGVF36Pの使用説明書/サービス説明書
ページ先へ移動 of 20
1 W415-0297 / D / 04.03.03 CERTIFIED UNDER AMERICAN NA TIONAL ST ANDARDS, ANSI Z21.11.2, VOL UME II FOR UNVENTED ROOM HEA TERS. UNVENTED MILLIVOL T SYSTEM INST ALLA TION AND OPERA TION INSTRUCTIONS FO.
2 W415-0297 / D / 04.03.03 WARNING • • Under no circumstances should this heater be modified. • Pr ovide adequate ventila tion and combustion air . Pro vide adequate accessibility c learance f servicing and oper ating the heater . Nev er obstruct the fr ont opening of the heater .
3 W415-0297 / D / 04.03.03 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work.
4 W415-0297 / D / 04.03.03 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERVICED BY A QUALIFIED INST ALLER to conform with local codes. Installation practices vary from region to re- gion and it is imp.
5 W415-0297 / D / 04.03.03 ROOM 2 ROOM 1 This heater shall not be installed in a confined space or unusually tight construction unless provisions are pro- vided for adequa te combustion and ventila tion air .
6 W415-0297 / D / 04.03.03 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the ¼"ø holes located at either end of the base.
7 W415-0297 / D / 04.03.03 NAILING TA B T o install the fireplace face flush with the finished wall, position the framework to accommodate the thick- ness of the finished wall. Bend out the four nailing tabs, attached on either side of the fireplace and secure to the 2x4 framing.
8 W415-0297 / D / 04.03.03 The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring. The heater must not be used when the hood is removed.
9 W415-0297 / D / 04.03.03 PHAZER TM logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every inst allation. T ake the time to care- fully position the glowing embers for a maximum glowing effect.
10 W415-0297 / D / 04.03.03 UPPER L OUVRES: In- sert the upper louvres into the slots on both brackets. Press the top flange of the hood into the four clips located along the top of the unit as shown. L OWER LOUVRES: At- tach each hinge to the fire- bo x with 2 screws.
11 W415-0297 / D / 04.03.03 NO TE : ORNAMENT AL INSETS CAN NOT BE USED IN CONJUNCTION WITH THE CA T AL YTIC DOOR This unique patented catalytic system was designed to provide unparalleled safety and peace of mind.
12 W415-0297 / D / 04.03.03 Attach the connectors from the black and red wires to the blower . Attach and secure the variable speed switch using the nut pro- vided. Plug the harness cord into the receptacle. The wire harness provided in this kit is a univer- sal harness .
13 W415-0297 / D / 04.03.03 FIGURE 27 This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, which may be ordered from your Wolf Steel /Napoleon dealer.
14 W415-0297 / D / 04.03.03 P I N O L O T F F O When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting.
15 W415-0297 / D / 04.03.03 This procedure must be performed by a qualified service person! Inspect the pilot for any visible contamination or debris (usually lint, pet hair , spider webs, carpet fibre, etc.) and remove. Disconnect the pilot from the pilot tubing line.
16 W415-0297 / D / 04.03.03 Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Napoleon dealer or distribu- tor . When ordering replacement parts always give the follow- ing information: 1.
17 W415-0297 / D / 04.03.03.
18 W415-0297 / D / 04.03.03 Main burner goes out; pilot stays on. Pilot flame is not large enough or not engulfing the thermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the valve.
19 W415-0297 / D / 04.03.03 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites.
20 W415-0297 / D / 04.03.03 Wolf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer.
デバイスNapoleon Grills GVF36Pの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Napoleon Grills GVF36Pをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはNapoleon Grills GVF36Pの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Napoleon Grills GVF36Pの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Napoleon Grills GVF36Pで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Napoleon Grills GVF36Pを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はNapoleon Grills GVF36Pの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Napoleon Grills GVF36Pに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちNapoleon Grills GVF36Pデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。