1 Rev . F 1-22-04 P/N 471 105 FOR YOUR SAFETY - READ BEFORE OPERA TING W arning: If you do not follow these instructions exactly , a fire or explosion may result, causing property damage, personal injury or loss of life. Call (800) 831-7133 for additional free copies of these instructions.
2 P/N 471 105 Rev . F 1-22-04 TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Rev . F 1-22-04 P/N 471 105 Introduction MiniMax ® 75 & 100 ABOVEGROUND POOL AND SP A HEA TERS Congratulations on your purchase of a MiniMax 100 high performance heating system. Proper installation and service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment.
4 P/N 471 105 Rev . F 1-22-04 SAFETY RULES 1. Spa or hot tub water temperatures should never exceed 104 °F (40 °C). A temperature of 100 °F (38 °C) is considered safe for a healthy adult.
5 Rev . F 1-22-04 P/N 471 105 FOR YOUR SAFETY : READ BEFORE LIGHTING A. This heater is equipped with an ignition device which automatically lights the main burner . Do not try to light the main burner by hand. B. BEFORE OPERA TING smell all around the heater area for gas.
6 P/N 471 105 Rev . F 1-22-04 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2 . Set the thermostat to the lowest setting. 3 . T urn off all electric power to the heater . 4 . Remove the control access door . 5 . Push in the gas control valve slightly and turn clockwise to "OFF"; see Figure 2.
7 Rev . F 1-22-04 P/N 471 105 HEA TER OPERA TION GENERAL The MiniMax 100 DSI employs a microprocessor based Direct Spark Ignition (DSI) system to light the main burner and therefore has no pilot. The ignition circuit operates at 24 V AC and requires that line voltage 1 15/230 be supplied to the heater .
8 P/N 471 105 Rev . F 1-22-04 Failure to Light- Lockout 1. Should the main burner fail to light, or flame is not detected during the trial-for-ignition (TFI) period the control will go into lockout and the valve will be turned off immediately .
9 Rev . F 1-22-04 P/N 471 105 Proper Electrode Location Proper location of the ignition electrode assembly is important for optimum and safe system performance. The electrode assembly should be located as noted in Figure 6. The electrode assembly is NOT field repairable and must be replaced if damaged.
10 P/N 471 105 Rev . F 1-22-04 Maintenance It is recommended that you check the following items at least every six months and at the beginning of every swimming season. 1. Examine the venting system. Make sure there are no obstructions in the flow of combustion and ventilation air .
11 Rev . F 1-22-04 P/N 471 105 CHEMICAL BALANCE POOL AND SP A W A TER Y our Pentair Pool Products pool heater was designed specifically for your spa or pool and will give you many years of trouble free service provided you keep your water chemistry in proper condition.
12 P/N 471 105 Rev . F 1-22-04 Installation Instructions IMPOR T ANT NOTICE: These installation instructions are designed for use by qualified personnel only , trained especially for installation of this type of heating equipment and related components.
13 Rev . F 1-22-04 P/N 471 105 PRESSURE SWITCH The pressure switch will keep the circuit open when the pump is not on and operating. When the filter pump turns on, the pressure switch closes the circuit and the heater will operate. When the heater is installed below water level of a spa or pool, adjustment of the pressure switch may be required.
14 P/N 471 105 Rev . F 1-22-04 Installation (contd.) W A TER CONNECTIONS QUICK-FLANGE II INST ALLA TION INSTRUCTIONS Figure 12. FOR 1½ SCHEDULE 40 CPVC or ABS PIPE or SCHEDULE 80 PVC (you may adapt to SCH 40 PVC 12 inches beyond the Quick Flange II) (1½ in.
15 Rev . F 1-22-04 P/N 471 105 GAS CONNECTIONS REGULA TED MANIFOLD PRESSURE TEST 1. Attach the manometer to the heater jacket. 2. Shut off the main gas valve. 3. Remove 1/8" NPT plug on the outlet side of the valve and screw in the fitting from the manometer kit.
16 P/N 471 105 Rev . F 1-22-04 VENTILA TION OUTDOOR INST ALLA TION This heater is certified by International Approval Services (AGA & CGA) for outdoor installation. If the heater is installed in very cold areas proper precau- tions are needed for freeze protection.
17 Rev . F 1-22-04 P/N 471 105 INDOOR INST ALLA TION The installation of venting system should conform with the latest edition of ANSI Z223.1, the National Fuel Gas Code, and/or in Canada, CAN/CGA-B149.1 or .2 or applicable provision of the local codes.
18 P/N 471 105 Rev . F 1-22-04 Installation - V entilation (contd.) Fig. 18. Draft Hood. VENT TEST Use the following steps to perform a quick check of your venting installation. Allow the heater to operate for 15 minutes. Close the doors in the room, then strike a wooden match and blow out the flame.
19 Rev . F 1-22-04 P/N 471 105 Installation (contd.) MiniMax 100 Electronic Direct Spark Ignition Wiring Diagram THERMAL FUSE HI LIMIT SW. PRESSURE SW. WATER THERMOSTAT ON/OFF SW. IGNITER SPARK MODULE GAS VALVE MiniMax 100 ELECTRONIC WIRING DIAGRAM CODE OR SUPERCEDING LOCAL (WIRING) CODES.
20 P/N 471 105 Rev . F 1-22-04 TROUBLESHOOTING - GENERAL Possible Cause Remedy Heater will not come on Automatic ignition system fails Check if electrical connections are correct and securely fastened – If YES, call serviceman.
21 Rev . F 1-22-04 P/N 471 105 PARTS LIST ITEM DESCRIPTION QTY. P/ N 1* Indoor Draft Hood Kit consisting of: 1 4 7 1 1 8 7 Indoor Draft Hood (471 198) and items 2 & 3 1A Outdoor T op 1 471213 2* I.
22 P/N 471 105 Rev . F 1-22-04 EXPLODED VIEW 33 14 13a.
23 Rev . F 1-22-04 P/N 471 105 NOTES.
24 P/N 471 105 Rev . F 1-22-04 Pentair Pool Products 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 SAVE THESE INSTRUCTIONS.
デバイスPentair 75の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Pentair 75をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPentair 75の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Pentair 75の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Pentair 75で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Pentair 75を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPentair 75の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Pentair 75に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPentair 75デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。