050505-36 36ARB2 5056.428091 WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal injury or loss of life. -- Do not store or use gasoline or other ammable vapours and liquids in the vicinity of this or any other appliance.
2 36ARB2 050505-36 Contents CAUTION .............................................................................................................. 3 SAFETY ...............................................................................................
050505-36 36ARB2 3 CAUTION FOR YOUR SAFETY - Do not install or operate your Town and Country replace without rst reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town and Country Fireplaces TM Warranty and may prove hazardous.
4 36ARB2 050505-36 Minimum Clearances to Combustibles: Side standoffs ...................... 0 in. (0 mm) Back standoffs ..................... 0 in. (0 mm) Top standoffs ....................... 0 in. (0 mm) Bottom of appliance ............. 0 in. (0 mm) Adjacent sidewall .
050505-36 36ARB2 5 INSTALLATION REQUIREMENTS The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes.
6 36ARB2 050505-36 FRAMING AND FINISHING Note: The replace must be in place and venting installed before framing in or building an enclosure around the unit. The Town & Country Fireplace must be framed in as described below or totally enclosed with non-combustible material, such as facing brick.
050505-36 36ARB2 7 Concrete board (or other non- combustible material) must extend 12" above and 4 1/2" to the sides of the framing edges. CONCRETE BOARD CONCRETE BOARD DETAIL Fig.
8 36ARB2 050505-36 1 / 4" 1" MAX HEARTH EXTENSION While a hearth extension is not required for this replace, one is recommended for aesthetic reasons. The hearth extension should be noncombustible and must not be any more than 1" above the bottom of the replace.
050505-36 36ARB2 9 9 3/8" 12" 4 1/4" CONTROL BOX LOCATION AND FRAMING DETAIL Fig. # 12 CAUTION: - A 2 foot service access clearance is recom- mended in front of the control box. - If recessed into a masonry wall, allow for control door and frame removal.
10 36ARB2 050505-36 VENTING Before installing venting for this unit, the installer should read these instructions to insure that the proper vent con guration has been selected. Use only Town and Country Termination kits #: TCVT.WTA - Wall Termination Kit TCVT.
050505-36 36ARB2 1 1 Wall thimble: Where a vent pipe passes through a combustible wall, a wall thimble/shield must be used to retain insulation and maintain proper clearances. The wall thimble may be cut to length for various wall thicknesses up to 12" thick.
12 36ARB2 050505-36 Vent pipe: Install vent pipe through the wall thimble and attach to ue outlet collar on top of the replace. Secure all joints with screws and seal with approved "High Temp." self-adhesive aluminum tape provided (see VENT PIPE SEALANT section).
050505-36 36ARB2 13 A Minimum rise B Pipe length C Maximum run D Pipe length Maximum 68 1/2” 24” 18" 1' 74 1/2” 30” 76" 5' 80 1/2” 36” 11' 2 1/8" 10' 86 1/2” 42” 16' 15' 92 1/2” 48” 20’ 10 1/4” 20' For other rise/run combinations see chart below Fig.
14 36ARB2 050505-36 ROOF TERMINATION VENTING CHART Fig. # 18 NOTE: The vent must not exceed a total length of 68 feet. Any combination of rise and run may be used but must be con- strained to the boundaries of this chart. A total of 4 90° elbows or combination of other elbows equalling 90° can be used without reducing horizontal run.
050505-36 36ARB2 15 ROOF SUPPORT BRACKET (TCVT.93915) VENT PIPE ROOF TERMINATION VENTING Ceiling opening: 1) Determine the exact position of the replace so that the vent pipe is centered (if possible) between two building framing members. Lay out the vent system path, minimiz- ing the number of elbows and length of vent.
16 36ARB2 050505-36 Fig. # 21 VERTICAL TERMINATION CAP (TCVT.9365) FLASHING STORM COLLAR (TC42.90665) MASTIC Note: Adjustable for various roof pitches, from at roof to 12/12 pitch roof.
050505-36 36ARB2 17 36" 24" 48" ADJ ACENT 24" (91 .5 cm) (61 cm) (61 cm) (1 22 cm) STR UCTURES OR FENCE VENT TERMINAL CLEARANCE Minimum clearances to the vent terminal must be maintained as shown in gure #22a & b. Measure clearances to the nearest edge of termination hood.
18 36ARB2 050505-36 VENT PIPE SEALANT APPROVED "HIGH TEMP." SELF-ADHESIVE ALUMINUM TAPE Fig. #23 VENT PIPE SEALANT All outer joints of the vent pipe must be sealed with the ap- proved "High Temp." self-adhesive aluminum tape provided.
050505-36 36ARB2 19 VENT RESTRICTOR ADJUSTMENT The vent restrictor is located on the underside of the rebox top. The unit leaves the factory with the vent restrictor wide open. The restrictor is built into the appliance for secondary air ow adjustment.
20 36ARB2 050505-36 GAS SUPPLY Caution: The gas line should be installed by a quali ed service person in accordance with all building codes. This section is intended as a guide for quali ed technicians installing this appliance. Consult local and/or national building codes before proceeding.
050505-36 36ARB2 21 WINDOW FRAME REMOVAL Warning: Turn off the replace, and allow ample time for the unit to cool before proceeding. Caution: The ceramic glass is very fragile, and should be handled with care. The window frame is held in place by two spring-loaded latches and are operated by a removable handle.
22 36ARB2 050505-36 FIREBOX PANELS INSTALLATION (HERRINGBONE .................. TCPN.7566) (TUSCAN ................................ TCPN.748) (HERITAGE RED ................ TCPN.75704) For porcelin panel kit (TCPN.75702) installation see in- structions provided with panel kit.
050505-36 36ARB2 23 LIGHTING INSTRUCTIONS - Millivolt Valve TO TURN OFF GAS T O APPLIANCE LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this label. 2. Set wall thermostat to lowest setting, if applicable. 3. T urn off all electric power to the appliance, if applicable.
24 36ARB2 050505-36 BURNER CONTROL HI-LO Control Knob Fig. # 33 1) HI-LO Flame Adjustment: The HI-LO burner control knob can be rotated in both direc- tions, providing in nite control of gas ow rate to the burner and therefore greater comfort control.
050505-36 36ARB2 25 Fig. # 35 THERMOCOUPLE THERMOPILE PILOT FLAME ELECTRODE APPENDIX A MAINTENANCE Caution: Turn off gas and electrical power supply (if appli- cable) and allow ample time for unit to cool before servicing appliance.
26 36ARB2 050505-36 REPLACEMENT PARTS (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1............ GLASS FRAME ........................... TC36.9520WLD 2............ REPLACEMENT GLASS (c/w gasket) GLAS.
050505-36 36ARB2 27 REPLACEMENT PARTS-MILLIVOLT CONTROL ASSEMBLY (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM ..... DESCRIPTION ...................................... PART NO. ITEM ...... DESCRIPTION .................................... PART NO.
28 36ARB2 050505-36 REPLACEMENT PARTS - ELECTRONIC CONTROL ASSEMBLY ITEM ..... DESCRIPTION ...................................... PART NO. ITEM ...... DESCRIPTION .................................... PART NO. 1............ ELECTRONIC, VALVE, NG ......
050505-36 36ARB2 29 ELECTRONIC VALVE WIRING DIAGRAM Fig. # 39 S I CAUTION: TP TH TP TH VENT LO HI OUT IN PILOT TH TP TH TP Ignition Module Pilot Assembly Black (S) [through Gas line conduit] Electrode.
30 36ARB2 050505-36 WALL TERMINATION KIT TCVT.WTA Fig. # 40 WALLSHIELD/CEILING FIRESTOP THIMBLE TCVT.THIMA WALL TERMINAL TCVT.9360 WALL SHIELD/CEILING FIRESTOP THIMBLE TCVT.
050505-36 36ARB2 31 ROOF TERMINATION KIT TC36.RTA Fig. # 42 ROOF SUPPORT BRACKET TCVT.93915 STORM COLLAR TC42.90665 VERTICAL TERMINATION CAP TCVT.9365 CEILING FIRESTOP TCVT.
32 36ARB2 050505-36 VENT PIPE DIMENSIONS Fig. # 43 45° 11" 9 1/2" 10 15/16" 10 5/16" 15 7/8" 7/16" 1 5/16" 8 5/16" 13 13/16" 12 9/16" 13 1/8" * 11 1/8" TCVT.811X12ADJ TCVT.811XLB45 TCVT.811XLB90 TCVT.
050505-36 36ARB2 33 11 3/8" 10 7/8" 1 1/4” B A C 1 1/4” 6 1/8" 1 1/4” 16 1/16” B A C 1 1/4” 18 5/8" 1 1/4” 20" B A 1 1/4” 20” VENT OFFSET CHART A B C 12" Pipe......18 5/8"........18" 18" Pipe.
34 36ARB2 050505-36 VARIOUS GAS SUPPLY CONNECTIONS Note: Consult local codes before proceeding. FLEXIBLE CONNECTOR WITH SHUTOFF VALVE BLACK IRON PIPE WITH UNION COPPER LINE WITH FLARE FITTING GASTITE TM FLEX LINE WITH REDUCING COUPLING Fig. # 45 Fig. # 46 Fig.
050505-36 36ARB2 35 SAFETY LABEL LOCATION NOTE: On appliances equipped with Electronic Ignition, the Safety Label is located behind the lower control panel. CONTROL BOX SAFETY LABEL LOWER CONTROL PANEL Optional components: Remote Heat Kit (TC36.RHKA), Propane Conversion Kit (TC36.
2975 Allenby Rd., Duncan, BC V9L 6V8 Phone: 1-888-223-0088 Web site: www.townandcountry replaces.net Printed in Canada.
デバイスPGS TC36 ARの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
PGS TC36 ARをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはPGS TC36 ARの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。PGS TC36 ARの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。PGS TC36 ARで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
PGS TC36 ARを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はPGS TC36 ARの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、PGS TC36 ARに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちPGS TC36 ARデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。