Quadra-FireメーカーQVI-30FBの使用説明書/サービス説明書
ページ先へ移動 of 25
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 1 Model: QVI-30FB In the Commonwealth of Massachusetts: • installation must be performed by a licensed plumber or gas fitter; See T able of Contents for location of additional Commonwealth of Massachusetts requirements.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 3 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 4 4 1 6 2 7 3 5 8 9 10 11 13 14 15 16 17 19 20 18 12 Part number list on following page. Log Set Assembly Service Parts Diagram Service Parts QVI.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 5 Service Parts List QVI-30FB Î I TEM DES CRIP TI O N S ERIAL # P ART NUM BER Log S et A s s em bly LO G S- Q V I 30F B Y 1 Log 1 S R V 2020-140.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 6 V alve Assembly Part s Diagram Service Parts QVI-30FB 6 7 8 9 10 1 2 5 4 3 IT E M D E SC R IPTIO N SE R IA L # PA R T N U MB E R 1 Fl ex B al l.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 7 Appliance Certification The Quadra-Fire appliance discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 8 NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 9 2 Getting St arted Introducing the Quadra-Fire Gas Appliances Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 10 QVI -3 0 F B MI N I MU M F IR E P L AC E S IZE Lo cation I n ches Mi llimeters A F ron t Wi dth 30-1/ 4 768 B R ear Width 19 483 C D epth 14-1.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 11 Q VI -3 0FB M O DEL DI M ENSI O NS Locat i on Inches M illimete rs A 18 457 B6 - 1 / 2 1 6 5 C 29-3/ 8 746. 1 D 26-1/ 1 6 661 E 20-5/ 8 524 F 14-5/ 8 371 G 22-1/ 8 562 H 21-1/ 4 540 Dimensions in brackets are millimeters.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 12 3 Inst alling the Insert Step 1. Inst alling the V ent System V ent System Inst allation Precautions Before starting installation of vent kits, the installer should read these instructions and the V ent Kit Instructions to ensure that a proper vent installation is completed.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 13 ! Attach the flashing and termination cap to the top of the flexible vent pipe and set the cap in place.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 14 Figure 4. This option shows both exhaust and inlet air vent pipes attached to the adaptor. W ARNING: THE EXHAUST VENT PIPE MUST ONL Y BE CONNECTED TO THE EXHAUST ST ARTING COLLAR OF THE UNIT AND THE CENTER COLLAR OF THE TERMINA TION CAP .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 15 Figure 5. T ypical configuration of vent liners. Note: Inspect for exhaust collar gasket to insure positive exhaust seal.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 16 Step 2. Positioning, Leveling, and Securing the Insert • Place the insert into position. • Level the insert from side to side and from front to back. Use the leveling legs if necessary to set each corner of the base.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 17 Step 5. Gas Pressure Requirements Pressure requirements for these gas appliances are shown in the table below . Pressure Natural Gas Propane Minimum 5.0 inches 1 1.0 inches Inlet Pressure w .c.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 18 Serving the blower On units already installed removal of decorative front, sur- round and gas insert is required. • Detach flexible liner from the top of unit. • Remove the four screws on the coverplate (see Figure 1 1).
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 19 Step 7. Installing Logs and Ember Material Positioning the Logs The logs have been packaged sep arately . Refer to the installation instructions that accompany this manual. Save the log instructions with this manual.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 20 Step 9. Before Lighting the Appliance Before lighting the appliance, be sure to do the following: Remove all paperwork from the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 21 Step 10. Lighting the Appliance ST ANDING PILOT IGNITION A . This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 22 4 Maint aining and Servicing Y our Appliance Appliance Maintenance Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check- up at the beginning of each heating season.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 23 T roubleshooting With proper installation, operation, and maintenance your gas fireplace will provide years of trouble-free service.
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 24 Sym pto m P ossible Cause C orrect ive A cti on 4. Fr equ en t pi lot ou t age probl em. a. P i lot f lam e may be too h i gh or t oo low , or bl owin g (h i gh ), cau si n g pi l ot saf ety to dr op ou t .
Quadra-Fire • QVI-30FB • 2020-900 Rev . H • 9/07 25 Lifet ime Warrant y LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime Warranty guarantees that the following component s will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
デバイスQuadra-Fire QVI-30FBの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Quadra-Fire QVI-30FBをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはQuadra-Fire QVI-30FBの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Quadra-Fire QVI-30FBの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Quadra-Fire QVI-30FBで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Quadra-Fire QVI-30FBを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はQuadra-Fire QVI-30FBの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Quadra-Fire QVI-30FBに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちQuadra-Fire QVI-30FBデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。