RaypakメーカーD-2 POWER VENT 206Aの使用説明書/サービス説明書
ページ先へ移動 of 20
INST ALLA TION & OPERA TING INSTR UCTIONS SWIMMING POOL & SP A HEA TER D-2 Catalog No. 6000.57.1D Effective: 05-21-10 Replaces: 10-26-06 P/N 241243 Rev . 3 W ARNING: If these instructions are not followed exactly , a fire or explosion may result causing property damage, personal injury or death.
2 Rev . 3 reflects the following: Changes to: Parts photos on page 3, dimensional illustration on page 4, Fig. 1 and Fig. 3 on page 5, Illustrated Parts List on page 19.
3 RECEIVING EQUIPMENT On receipt of your equipment, it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton.
4 INST ALLA TION REQUIREMENTS Failure to install, maintain and/or operate the Power V ent in accordance with manufacturer ʼ s instructions may result in conditions which can produce bodily injury and property damage.
5 INST ALLA TION 1 . Start off by disconnecting main power to the heater . 2. Remove the front door from the heater . See Fig 1. 3. If this is a retro-fit application, remove existing “Pagoda T op” and discard. See Fig. 2. If equipped with a drafthood, refer to drafthood installation manual for removal process.
6 INST ALLA TION (Continued) 6 . Lower the jacket top back onto the heater and reinstall the (6) Phillips screws. See Fig. 3. 7. If installing on a model 266, 267, 406 or 407 heater , skip step 8. 8. T urn t he Po wer V ent u psi de do wn . Usi ng a 5/ 16” n ut dr iv er , re loc ate t he mo un tin g bra cke ts as s ho wn in F ig.
7 INST ALLA TION (Continued) 1 3. Install the right side outdoor conduit through the top 7/8” hole located on the right side of the heater . See. Fig.
8 INST ALLA TION (Continued) 1 9. Route the 24 V AC harness through the 7/8” grommet, See Fig. 17. 20. Continue to route the harness down through any available grommet hole. See Fig. 18. 21. Wire the harness along with the installed gas valve harness per the wiring diagram.
9 U.S. Ins tallations 1 Canad ian Inst alla tions 2 A Clear ance above gr ade , veranda, p orch , deck, or balco ny 1 ft (30 c m) 1 ft (30 c m) B Clear ance to window or do or that may b e o pened 4 ft (1.
10 VENTING (Continued).
11 VENTING (Continued).
12 VENTING (Continued).
13 VENTING (Continued).
14 SEQUENCE OF OPERA TION On call for heat, the PC board will go through its safety chain (water pressure switch, high limit 1 & 2, roll-out, etc.). When the safety chain is closed, the IID pilot will begin to spark and the pilot gas valve will open.
15 WIRING (Continued) STEP 1 : VERIFY CURRENT CONNECTIONS AS SHOWN BELOW . P/PV C/ M/MV MV PV R/BK Y/BK Y/BK V/BK V/BK V/BK Y/BK G/BK P4 1 RELA Y D-2 POWER VENT Y/BK HONEYWELL V AL VE Y/BK V/W V/BK HONEYWELL V AL VE PV MV M /MV C/ P/PV STEP 2 : DISCONNECT BOTH TERMINALS MVPV & MV AS SHOWN BELOW .
16 WIRING (Continued) MODELS 206, 266, 336, 406 EQUIPPED WITH HONEYWELL GAS V A LV E V/W V/BK V/BK G/BK R/BK 1 P4 D -2 POWER VENT P/PV C/ M/MV MV PV HONEYWELL V AL VE STEP 4 : CONNECT THE MAIN V AL VE LINE, FEMALE SP ADE TO MALE SP ADE AS SHOWN BELOW .
17 WIRING DIAGRAM – MODELS 207A, 267A, 337A, 407A POWER VENT D-2 D-2 BLOWER POWER VENT GAS V AL VE HONEYWELL 1 1 + -.
18 WIRING DIAGRAM – MODELS 206A, 266A, 336A, 406A POWER VENT D-2 D-2 BLOWER POWER VENT + - 1 1 TH TR.
19 REPLACEMENT P ARTS NOTE: T o supply you with the correct part, it is impor- tant that you supply the heater model number , serial number and type of gas when applicable.
20 w w w .r ay pak .co m Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 Fax (805) 278-5468 Litho in U.S.A..
デバイスRaypak D-2 POWER VENT 206Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Raypak D-2 POWER VENT 206Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRaypak D-2 POWER VENT 206Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Raypak D-2 POWER VENT 206Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Raypak D-2 POWER VENT 206Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Raypak D-2 POWER VENT 206Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRaypak D-2 POWER VENT 206Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Raypak D-2 POWER VENT 206Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRaypak D-2 POWER VENT 206Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。