908-037 01/15/04 Owners & Installation Manual Fireplace Products International Ltd. 6988 Venture St., Delta, B.C. Canada, V4G 1H4 Tested by: Warnock Hersey: Masport Head Office - Australia 54 Boundary Rd. Braeside P.O. Box 553 Mordialloc 3195 Ph. (03) 9586-7777 Fax.
2 U20/E21 Gas Insert Zero Clearance Kit T ABLE OF CONTENTS U20/E21 GAS INSERT ZERO CLEARANCE KIT CONTENTS PAGE Listings & Code Approvals .................................................. 3 Specifications ..........................................
3 U20/E21 Gas Insert Zero Clearance Kit Specifications INST ALLA TION LISTINGS AND CODE APPROVALS This gas component has been tested in accordance with National Safety Standards, and has been certifie.
4 U20/E21 Gas Insert Zero Clearance Kit P ARTS Included with Kit: 1 Main Body Assembly (5 pieces) 1 Faceplate Top Insulation 1 Zero Clearance Top Louver Assembly Sold Separately: (Rq)=Required (Rq) 1 402-918 Faceplate 40-1/4"W x 26-1/4"H (1020mm W x 665mm H) c/w faceplate trim.
5 U20/E21 Gas Insert Zero Clearance Kit INST ALLA TION A D E C F B LOCA TING YOUR U20/E21 FIREPLACE Due to high temperatures the Insert should be located out of traffic and away from furniture and draperies. Provide a minimum of 48" (1220mm) front clearance to the unit.
6 U20/E21 Gas Insert Zero Clearance Kit INST ALLA TION KIT ASSEMBL Y Parts 1) Top Assembly 2) Base Assembly 3) Back Panel 4) Left Side Panel 5) Right Side Panel 6) Gas Line Cover Plate Kit Assembly 1) Lay the Base Assembly on a flat surface. 2) Attach the Left and Right Side panels to the Back panel (one screw each side).
7 U20/E21 Gas Insert Zero Clearance Kit Variable Chimney Routes VENTING 1) This fireplace must be vented with a 4" (100mm) diameter Class “B” vent. The installation of the venting system must conform and be in accordance with the natural gas installation code CAN/CGA - B149 (Canada), ANSI Z223.
8 U20/E21 Gas Insert Zero Clearance Kit INST ALLA TION INSERT INST ALLA TION 1) Insert the U20/E21 Zero Clearance box into desired location and frame according to the instructions on page 5. 2) Run required gas and electrical connections to the Zero Clearance box, both are located on the left hand side of the U20/E21 Insert.
9 U20/E21 Gas Insert Zero Clearance Kit INST ALLA TION OPTIONAL OUTSIDE COMBUSTION AIR SUPPL Y INST ALLA TION A 4" (100 mm) dia. aluminum flex pipe or equivalent may be installed from the outside (with a proper exterior cover) to the Zero Clearance cabinet.
10 U20/E21 Gas Insert Zero Clearance Kit ON/OFF Switch Fan Speed Switch (Rear View) Wires to Fan Switch Connectors Self-adhesive Wire Clip For Gas Connection Wires to On/Off Switch POWER CORD (3ft) Di.
11 U20/E21 Gas Insert Zero Clearance Kit INST ALLA TION Diagram 4 10) Attach the brass trim to the faceplate by drilling a 1/8" (3mm) hole through the faceplate using the hole in the trim as a guide. Fasten the trim to the faceplate panels using the plated screws.
Printed in Canada.
デバイスRegency E21の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency E21をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency E21の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency E21の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency E21で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency E21を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency E21の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency E21に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency E21デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。