W ARNING: If the information in these instructions are not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Regency ® E33S-1 Sunrise Gas Insert 2 FPI GAS FIREPLACE INSERT TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Inser t by FPI. The E33 Sunrise TM Gas Inser t has been designed to pro vide you with all the w armth and char m of a fi replace , at the fl ick of a s witch.
Regency ® E33S-1 Sunrise Gas Insert 3 T ABLE OF CONTENTS SAFETY LABEL Copy of the Safety Label ............................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 UNIT DIMENSIONS Unit Dimensions .
Regency ® E33S-1 Sunrise Gas Insert 4 INST ALLA TION SAFETY LABEL This is a copy of the safety label that accompanies the E33 Sunrise TM Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on a plate inside the base of the unit visible when the bottom louver is opened.
Regency ® E33S-1 Sunrise Gas Insert 5 INST ALLA TION REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side w.
Regency ® E33S-1 Sunrise Gas Insert 6 INST ALLA TION UNIT DIMENSIONS.
Regency ® E33S-1 Sunrise Gas Insert 7 INST ALLA TION INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The FPI Gas Insert must be installed in accord- ance with these instructions.
Regency ® E33S-1 Sunrise Gas Insert 8 INST ALLA TION INST ALLA TION 1 1) Due to high temperatures, the appliance should be located out of high traf fi c areas and away from furniture and draperies.
Regency ® E33S-1 Sunrise Gas Insert 9 INST ALLA TION INST ALLA TION MINIMUM CLEARANCES T O COMBUSTIBLES From Unit Side W alls A* 8" (203 mm) Ceiling B 47" (1 194 mm) Min.
Regency ® E33S-1 Sunrise Gas Insert 10 INST ALLA TION INST ALLA TION VENTING THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEP ARA TE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
Regency ® E33S-1 Sunrise Gas Insert 11 INST ALLA TION INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® E33S-1 Sunrise Gas Insert 12 INST ALLA TION INST ALLA TION CONVERSION KIT #434-969FROM NG T O LP.
Regency ® E33S-1 Sunrise Gas Insert 13 INST ALLA TION INST ALLA TION.
Regency ® E33S-1 Sunrise Gas Insert 14 INST ALLA TION INST ALLA TION.
Regency ® E33S-1 Sunrise Gas Insert 15 INST ALLA TION WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. However , a 120V A.
Regency ® E33S-1 Sunrise Gas Insert 16 INST ALLA TION Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty . The remote control kit comes with a hand held transmitter , a receiver and a wall mounting plate.
Regency ® E33S-1 Sunrise Gas Insert 17 INST ALLA TION GLASS DOOR INST ALLA TION INST ALLA TION T o install the glass door, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, (see Diagrams 1 and 2).
Regency ® E33S-1 Sunrise Gas Insert 18 INST ALLA TION INST ALLA TION CONTEMPORAR Y F ACEPLA TE & DOOR FRAME INST ALLA TION 1) Bring the faceplate up in front of the unit and connect the red & black ON/OFF wires from the unit to the ON/OFF switch on the back of the left side of the faceplate.
Regency ® E33S-1 Sunrise Gas Insert 19 INST ALLA TION 6) Place 2 screws through the screw holes on the hinge and place a spacer over each screw . 7) Secure the hinge to the bottom fl ange of the fi rebox with 2 screws from step 6. Repeat for other side.
Regency ® E33S-1 Sunrise Gas Insert 20 INST ALLA TION OPTIONAL HEARTH TRIM INST ALLA TION The Hearth T rim is an option that can be used to fi nish of f the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace.
Regency ® E33S-1 Sunrise Gas Insert 21 OPERA TION OPERA TING INSTRUCTIONS IMPORT ANT : Gas on/off knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.
Regency ® E33S-1 Sunrise Gas Insert 22 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING INSTRUCTION PLA TE AUT OMA TIC CONVECTION F AN OPERA TION The fan operates automatically . T urn the knob on the side of the faceplate to adjust to the desired speed.
Regency ® E33S-1 Sunrise Gas Insert 23 MAINTENANCE MAINTENANCE GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi-annually . Recommended areas to inspect as follows: 1) Check the V enting System for corrosion in areas that are exposed to the elements.
Regency ® E33S-1 Sunrise Gas Insert 24 MAINTENANCE MAINTENANCE V AL VE TRA Y REPLACEMENT 1) Turn the unit of f and allow it to cool down to room temperature. 2) Disconnect the power source and turn off the gas supply to the insert. 3) Open the bottom louver .
Regency ® E33S-1 Sunrise Gas Insert 25 MAINTENANCE 9) Remove the base cover by lifting up from the back and maneover out. Base Cover 10) Disconnect the ON/OFF connector wires from the valve. NOTE: For LP units disconnect the DC Sparker ignitor wire from the valve.
Regency ® E33S-1 Sunrise Gas Insert 26 MAINTENANCE F AN REPLACEMENT 6) Remove the back shield by undoing the 2 screws shown. 9) Remove the base cover by lifting up from the back and maneover out. 7) Remove the burner by undoing the 2 screws shown. Carefully lift the burner up and out ensuring not to spill glass crystals.
Regency ® E33S-1 Sunrise Gas Insert 27 MAINTENANCE 10) Remove the fan access plate by undoing the 12 screws shown. 11 ) Remove the 2 screws that hold the pilot assembly in place and lift forward as shown below . 12) Remove the 2 screws that hold the fan in place and slide the fan towards the front of the unit.
Regency ® E33S-1 Sunrise Gas Insert 28 P ARTS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 1) 340-038 Fan Access Plate 2) 340-103 Gasket - Fan Access Plate 3) 320-517/P Fan Assembly 120 V 910-3.
Regency ® E33S-1 Sunrise Gas Insert 29 P ARTS LIST P ARTS LIST CONTEMPORAR Y F ACEPLA TE & DOOR FRAME Part # Description 341-914 Contemporary Faceplate & Door Frame 90) * Complete Faceplate 9.
Regency ® E33S-1 Sunrise Gas Insert 30 NOTES.
Regency ® E33S-1 Sunrise Gas Insert 31 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency E33Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency E33Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency E33Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency E33Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency E33Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency E33Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency E33Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency E33Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency E33Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。