RegencyメーカーG36D-LP PROPANEの使用説明書/サービス説明書
ページ先へ移動 of 40
FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-156b MODELS: G36D-NG Natural Gas G36D-LP Propane 01/04/06 G36D Zero Clearance Direct V ent Gas Fireplace Ow.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNA TIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS Operating Instructions Operating Instructions .............................................. 32 Lighting Procedure ................................................... 32 Shutdown Procedure .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 4 This is a copy of the label that accompanies each G36D Zero Clearance Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 5 INST ALLA TION CHECKLIST 1) Locate appliance a) Room location, page 6 b) Clearances to Combustibles, pages 6 -8. c) Mantle Clearances, page 8 d) Framing & Finishing Requirements, page 7 e) V enting Requirements, pages 10 - 17.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 6 INST ALLA TION Diagram 1 This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 26,000 Btu/h) after burning appliance for 15 minutes. 2) If required, adjusting the primary air to ensure that the fl ame does not carbon.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 7 MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: FRAMING AND FINISHING 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 8 INST ALLA TION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 9 "C" Screw Position: For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 10 INST ALLA TION EXTERIOR VENT TERMINA TION LOCA TIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 11 VENTING UltraGlow Direct V ent System (Flex) Horizontal T erminations Only These venting systems, in combination with the G36D Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W arnock Hersey .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 12 INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-V ent components are available directly from FPI.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 13 Rigid Pipe Adaptor (Part# 510-994) Pipe Length V ertical T erminal S torm Collar (Part # 953) Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" Pipe Length Adj.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 14 RIGID PIPE VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS UL TRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o elbow (two 45 o elbows equal one 90 o elbow).
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 15 INST ALLA TION RIGID PIPE VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS UL TRAGLOW DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram below shows examples of horizontal termination arrangements using two 90 o elbows (two 45 o elbows equal one 90 o elbow).
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 16 RIDID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 17 INST ALLA TION The G36D is approved for a maximum 37 ft. (1 1.3m) straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas, as per the diagram 3.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 18 INST ALLA TION VERTICAL TERMINA TION WITH CO-LINEAR FLEX SYSTEM This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 19 INST ALLA TION V enting Arrangements - V ertical T erminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 20 Diagram 4 6) The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to combustible materials are maintained (Diagram 4). Install the termination cap. NOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code requirements.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 21 INST ALLA TION Diagram 3 Diagram 5 Diagram 1 Diagram 2 Note: Apply sealant "Mill-Pac" to inner pipe and high temperature silicone seal- ant to outer pipe on every twist-lock joint.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 22 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 23 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve dur in g a ny pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 24 CONVERSION KIT FROM NA TURAL GAS T O PROP ANE MODEL #290-969 FOR G36D USING SIT 820 NOV A GAS V AL VE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the 2 screws, push Burner Assembly to the left and lift out.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 25 INST ALLA TION 5) Position Log 02-53 across the cutouts in Logs 02-75 and 02-51 with the notch on the left side of the log fi tting into the 2nd grate tab. Cutouts 2nd Grate T ab LOG SET INST ALLA TION Read the instructions below carefully and refer to the diagrams.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 26 INST ALLA TION Log indentation Photo shows rear grate tab. Log 02-51 was removed to show the posi- tioning of Log 02-52. Rear Grate T ab Rear Bracket 7) Place the bottom left front edge of Log 02-55 against the rear bracket on the burner tray and rest the log on the cutout on Log 02-53.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 27 10) Place the embers on the front of the burner tray in the places shown on the photos below . 11 ) T est fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of burner to the other).
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 28 Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 29 Thermostat Wire T able Option 3: W ALL THERMOST A T A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 30 WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 31 120 V olt AC power is needed for the fan switch and blower . A three wire power cord is provided to be plugged into the receptacle. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 32 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 33 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 34 MAINTENANCE 4) Make a periodic check of burner for proper position and condition. Visually check the fl ame of the burner periodically , making sure the fl ames are steady; not lifting or fl oating.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 35 13) Undo the pilot tube from the valve with a 7/16" wrench. 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 15) Remove the Piezo ignitor wire and push button assembly .
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 36 P ARTS LIST G36D MAIN ASSEMBL Y Part # Description Part # Description 1) 948-253 Door Handle 2) 510-026 Hinge Bracket - Left/Right 3) 948-04.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 37 G36D BURNER ASSEMBL Y & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) 780-021 Gasket - V alve Access Plate NG/LP 786-574/P V alve Assy - Natural Gas 786-576/P V alve Assy - Propane 56) * V alve T ray - NG/LP 57) 910-378 V alve - S.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 38 P ARTS LIST G36D FLUSH FRONT ASSEMBL Y Part # Description 131) 510-934 Flush Glass T rim (Set) - Brass 510-947 Flush Glass T rim (Set) - Ste.
UltraGlow G36D Zero Clearance Direct V ent Gas Fireplace 39 W ARRANTY UltraGlow products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our door .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency G36D-LP PROPANEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency G36D-LP PROPANEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency G36D-LP PROPANEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency G36D-LP PROPANEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency G36D-LP PROPANEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency G36D-LP PROPANEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency G36D-LP PROPANEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency G36D-LP PROPANEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency G36D-LP PROPANEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。