FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS OPERA TING INSTRUCTIONS Operating Instructions ................................................. 34 Lighting Procedure ..........................
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 4 This is a copy of the label that accompanies each P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 5 REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 6 INST ALLA TION CHECKLIST Note: These units are non-load bearing. 1) Locate appliance. Refer to the following sections: a) Locating Y our Fireplace b) Clearances c) Combustible Mantel Clearances d) Framing & Finishing e) V enting.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 7 INST ALLA TION SPECIFICA TIONS P121-2 See Thru P131-2 Pier Note: These units are non-load bearing.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 8 P121LC-2 Left Corner Unit P121RC-2 Right Corner Unit INST ALLA TION Note: These units are non-load bearing.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 9 LOCA TING YOUR GAS FIREPLACE 1) When selecting a location for your fi replace, ensure that the clearances are met as outlined in the "Clearances" section.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 10 INST ALLA TION COMBUSTIBLE MANTELS CLEARANCES The clearances listed below are Minimum distances unless otherwise.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 11 B C A FRAMING AND FINISHING P121-2 - See Thru P131-2 - Pier Framing Dimensions P121-2 (See Thru) P131-2 (Pier) P.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 12 VENTING INTRODUCTION The P121-2/P121LC-2/P121RC-2/P131-2 uses the "balanced fl ue" technology Co -Axial system.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 13 INST ALLA TION EXTERIOR VENT TERMINA TION LOCA TIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 14 INST ALLA TION FPI 946-506/P V ent Guard (Optional) 510-994 Rigid Pipe Adaptor (Must use with all Rigid Piping) .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 15 VENTING ARRANGEMENT - HORIZONT AL TERMINA TIONS Regency ® Direct V ent System (Flex) Horizontal T erminations O.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 16 Pipe Length V ertical T erminal S torm Collar Part # 953 Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" Pipe Length Adj.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 17 Option V H A) 1' (305mm) Minimum 3' (914mm) Maximum B) 2' (610mm) Minimum 6' (1.86m) Maximum C) 3' (914mm) Minimum 9' (2.7m) Maximum D) 4' (1.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 18 INST ALLA TION Diagram 3 Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with T wo (2) 90 o El.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 19 INST ALLA TION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINA TIONS (Propane & Natural Gas) • V ent must be supported at offsets • Maintain clearances to combustibles as listed in the "Clearances" section.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 20 INST ALLA TION V ertical V enting with T wo (2) 90 o Elbows Option V + V1 H A) 1' (305mm) Minimum 4' (1.22m) Maximum B) 2' (610mm) Minimum 6' (1.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 21 INST ALLA TION HORIZONT AL TERMINA TIONS Install the vent system according to the manufacturer's instructions included with the components. 1) Set the unit in its desired location.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 22 VERTICAL TERMINA TIONS 1) Maintain the 1-1/4" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter , or other nearby combustible surfaces.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 23 INST ALLA TION 5) Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up (there are markings on the cap that show which way is up).
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 24 CONVERSION KIT #731-969 FROM NG T O LP FOR P121-2/P121LC-2/P121RC-2/P131-2 USING SIT 820 NOV A GAS V AL VE THIS .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 25 Fig.3 17) Reverse steps 4) to 1). 18) Attach the label "This unit has been converted to LPG" near or on top of the serial # decal. 19) Replace yellow "NG" label with red "LPG" label.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 26 25) Locate the ground lug at the receptical box, left of the unit. Installer Notice: These instructions must be left with the appliance. 26) Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 27 P121/P121LC/P121RC/P131-NG1 System Data For 0 to 4500 feet altitude Burner Inlet Orifi ce Sizes: #31 Max. Input Rating 40,000 Btu/h Min. Input Rating 20,500 Btu/h Supply Pressure min.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 28 INST ALLA TION LOG INST ALLA TION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 29 INST ALLA TION 327 327 Repeat step 3 on the opposite side of the burner . Place Log 329 onto pin. 329 329 328 328 328 326 329 Grate Post 5) Place Log 329 on the middle left side of the burner .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 30 GLASS DOOR REMOV AL 1) Remove the 8 screws that secure the glass door . INST ALLA TION 2) Pull the door slightly out on an angle and then lift up and pull completely out.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 31 Option 1: REMOTE CONTROL Can be used with Option 2 o r 3 but not both. Use the Regency ® Remote Control Kit approved for this unit. Use of other systems may void your warranty .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 32 WIRING DIAGRAMS Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 33 T erminal Block Location T erminal Block Remove cover to access T erminal Block Lockwasher Ground Wire Nut #8 Gr.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 34 LIGHTING PROCEDURE NOTE: For all propane units and units equipped with electric spark boxes, see "Copy of Lighting Plate Instruc- tions" section for more details.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 35 COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 36 MAINTENANCE 2) Remove the Cap, and shine a fl ashlight down the V ent.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 37 12) Lift the entire assembly out. 8) Remove the Side Base Brick Panels and fi nally the Long Base Brick Panels. MAINTENANCE Remove Left & Right Side Base Brick Panels Remove the 2 Long Base Brick Panels 9) Disconnect the inlet gas line.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 38 F AN REPLACEMENT 1) Shut off power . 2) Remove top louvers. 3) Unplug power wires. 4) Remove 4 screws securing fan to mounting bracket. MAINTENANCE 5) Remove 2 connector wires.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 39 100 99 98 181 181 34 11 34 34 32 BR I CK PA N E L S 9 146 146 168 146 172 1 135 204 204 172 17 206 24 10 206 146.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 40 2 99 98 224 224 204 204 171 171 1 149 17 24 173 173 11 100 141 10 206 181 34 34 151 171 225 225 32 171 141 204 2.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 41 34 35 138 173 204 204 224 2 224 171 10 11 100 151 206 173 24 17 171 1 99 98 149 141 225 225 BR I CK PA N E L S 1.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 42 181 100 10 2 98 99 173 146 173 17 138 158 24 11 206 206 151 150 226 224 224 149 151 204 34 35 9 32 BR I CK PA N .
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 43 P121/P121LC/P121RC/P131-2 BURNER ASSEMBL Y & LOG SET P ARTS LIST Part # Description 360-930 Log Set 41) * Front Right Log 42) * Front Left Log 43) * Middle Left Log 44) * Middle Right Log 360-574/P V alve Assembly 56) 910-478 V alve S.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 44 NOTES ___________________________________________________ ___________________________________________________ __.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 45 NOTES ___________________________________________________ ___________________________________________________ __.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 46 NOTES ___________________________________________________ ___________________________________________________ __.
Regency ® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct V ent Gas Fireplace 47 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency P121の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency P121をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency P121の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency P121の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency P121で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency P121を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency P121の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency P121に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency P121デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。