FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-262a MODELS: P33-NG3 Natural Gas P33-LP3 Propane P33-3 Zero Clearance Direct V ent Gas Fireplace 01/04/06 O.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Stove by FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. The P33-3 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace T ABLE OF CONTENTS Louvers - Flush ........................................................ 29 Double Screen Door ................................................. 29 Bay Front (optional) .......
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace This is a copy of the label that accompanies each P33-3 Zero Clearance Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION IMPORT ANT : SA VE THESE INSTRUCTIONS The P33-NG3 or P33-LP3 Direct V ent Fireplace must be installed in accordance with these in- structions. Carefully read all the instructions in this manual fi rst.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION CHECKLIST 1) Locate appliance a) Room location, page 6 b) Clearances to Combustibles, page 7 c) Mantle Clearances, page 7 d) Framing & Finishing Requirements, page 8 e) V enting Requirements, pages 10 to 15.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace COMBUSTIBLE MANTELS INST ALLA TION Clearances for Bay or Flush Front Because of the extreme heat this fi replace emits, the mantel clearances are critical. Com- bustible mantel clearances from top of unit are shown in the diagram below .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace 16-1/2” (419mm) Minimum 4" (102mm) 3" (76mm) 1-1/2" (38mm) 30” (762mm) 10" (254mm) dia.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace The T op Facing Support, the Side Nailing Strips and the 2 T op Standof fs must be correctly po- sitioned and attached to the top before the unit is put into position.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace EXTERIOR VENT TERMINA TION LOCA TIONS INST ALLA TION . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Wherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Riser V ent T ermination Cap or the Dura-V ent Snorkel T ermination Cap. 6-7/8" (173mm) dia. Flue pipe 4" (102mm) dia.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace T ermination Cap W all Thimble 2 pieces (10" (254mm) Outer Diameter) 2 ”x4 ”o r2 ”x6 ” (21mm x 102mm or 21mm x 152mm) 6-7/8" (175mm) dia.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Pipe Length V ertical T erminal S torm Collar Flashing Ceiling Firestop 24" (610mm) Pipe Length Adj.Pipe Length 1 1" - 14-5/8" (279mm - 372mm) 90 Elbow o Horizontal T ermination Cap W all Thimble Vinyl Siding S tandoff (Optional) Rigid Pipe Adaptor 45 Elbow o Adj.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-V ent components are available directly from FPI.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid pipevent systems (Part # 510-994).
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace The P33-3 is approved for a maximum 40 ft. straight vertical, with rigid pipe vent systems for Propane and Natural Gas.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace RIGID PIPE VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o elbow (two 45 o elbows equal one 90 o elbow).
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows Option H V H + H1 + H2 A) 1 Max. 1' Min. 3' Max.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Horizontal V enting with Three (3) 90 o Elbows V ertical V enting with T wo (2) 90 o Elbows Option V H V + V1 A) 1' Min. 4' Max. 2' Min. B) 2' Min. 5' Max. 3' Min. C) 3' Min.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION V ertical V enting with Three (3) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (1 1m) Air Intake Co-linear DV V ertical T.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace V enting Arrangements - V ertical T erminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION Diagram 3 HORIZONT AL INST ALLA TIONS Diagram 1 b) Horizontal runs of vent must be sup- ported every three feet. W all straps are available for this purpose. 5) Mark the wall for a 10" x 10" square hole.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION GAS LINE INST ALLA TION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve dur in g a ny pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION Conversion Kit from Natural Gas to Propane Model #431-969 for P33-3 using SIT 820 NOV A Gas V alve Remove the 2 screws, push Burner Assembly to the left and lift out.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION Note: The logs must not be in the unit. 3) Insert the back brick panel by carefully slip- ping it between the back wall of the fi rebox and the rear log bracket. OPTIONAL BRICK PA N E L S 1) Undo the bottom 2 door latches and open and remove glass door .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard fl ush door comes with a black frame. T o install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace OPTIONAL BA Y DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the fl ush front.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace 6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace FULL SCREEN FRONT INST ALLA TION 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Face Plate Bracket into the bottom of the unit, secure it into the pins located on the inside of the fi re box.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION 6) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bottom Face Plate. Secure the hinges in place to the Bottom Frame, using 2x #8 Self T apping Phillips screws per hinge.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length. Note: Preferable if the thermostat is installed on an interior wall.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace INST ALLA TION INST ALLING THE OPTIONAL F AN 120 V olt AC power is needed for the fan switch and blower . The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electri- cian.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace OPERA TING INSTRUCTIONS COPY OF THE LIGHTING PLA TE INSTRUCTIONS.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace AERA TION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the bottom louver opening. Open the air shutter for a blue fl ame or close for a yellower fl ame.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace 10) Undo the pilot tube from the valve with a 7/16" wrench. REMOVING V AL VE 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace P ARTS LIST Main Assembly Part # Description Part # Description Part # Description 1) 948-247 Door Handle 2) * Thermodisc Bracket 7) 910-428 Dup.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace P ARTS LIST.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace Burner & Log Assembly Part Description 53) 430-055 Gasket - V alve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 910-422 Flame HI/LOW Extension Knob 56) 910-190 Piezo Ignitor and Nut 433-574/P V alve Assy - Natural Gas 433-576/P V alve Assy - Propane 57) 910-378 S.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace P ARTS LIST Flush Front & Louvers Part # Description Part # Description 1 17) 904-196 Magnet - 1' round 130) 430-924 Flush Glass T rim .
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace 430-930 Bay Front Complete 106) 940-079/P Side Glass 107) 936-243 Glass Gasket 108) 940-078/P Center Glass 1 10) * Bay Door Frame 1 1 1) 902-322.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace ___________________________________________________ ___________________________________________________ ________________________________________.
Regency P33-3 Zero Clearance Direct V ent Gas Fireplace W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency P33-NG3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency P33-NG3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency P33-NG3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency P33-NG3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency P33-NG3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency P33-NG3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency P33-NG3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency P33-NG3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency P33-NG3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。