T ested by: FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 918-661b MODELS: P40-NG1 Natural Gas P40-LP1 Propane P40 Gas Fireplace FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch: do not use any phone in your building.
Regency ® P40-1 Direct V ent Gas Fireplace 2 T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P40 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® P40-1 Direct V ent Gas Fireplace 3 T ABLE OF CONTENTS Conversion Kit #502-969 from NG to LP ..................... 27 Conversion Kit #502-966 from LP to NG ..................... 29 Brick Panel Installation ...................................
Regency ® P40-1 Direct V ent Gas Fireplace 4 INST ALLA TION INST ALLA TION This is a copy of the label that accompanies each P40-NG1 and P40-LP1 Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review . NOTE: Regency ® units are constantly being improved.
Regency ® P40-1 Direct V ent Gas Fireplace 5 INST ALLA TION INST ALLA TION 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For al.
Regency ® P40-1 Direct V ent Gas Fireplace 6 INST ALLA TION INST ALLA TION 34" (864mm) 40” (1016mm) 8” (203mm) Outer Dia. 5” (127mm) Inner Dia.
Regency ® P40-1 Direct V ent Gas Fireplace 7 INST ALLA TION INST ALLA TION IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The P40 Direct V ent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst.
Regency ® P40-1 Direct V ent Gas Fireplace 8 INST ALLA TION INST ALLA TION HEARTH REQUIREMENTS A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth is required, unless the unit is raised 4" (102mm). 4) This appliance is Listed for bedroom installations when used with the FireWizard (millivolt thermostat system).
Regency ® P40-1 Direct V ent Gas Fireplace 9 INST ALLA TION INST ALLA TION CLEARANCES The clearances listed below are minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials.
Regency ® P40-1 Direct V ent Gas Fireplace 10 INST ALLA TION INST ALLA TION 13” Mantel 8” Mantel 1” Mantel 33” to floor 2 0 12 14 6 4 8 10 17” 21” 2 0 12 6 16 18 20 4 14 8 10 Combustible .
Regency ® P40-1 Direct V ent Gas Fireplace 11 INST ALLA TION INST ALLA TION 10-1/4” Above Fireplace 6” 6” Diagram 1 1) Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 42-1/2" high x 40-1/2" wide x 20-1/16" deep (1080mm H x 1029mm W x 508mm D), see Diagram 1.
Regency ® P40-1 Direct V ent Gas Fireplace 12 INST ALLA TION INST ALLA TION VENTING INTRODUCTION The P40 uses the "balanced fl ue" technology Co Axial system.
Regency ® P40-1 Direct V ent Gas Fireplace 13 INST ALLA TION INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently closed window *#(min.
Regency ® P40-1 Direct V ent Gas Fireplace 14 INST ALLA TION INST ALLA TION VENTING ARRANGEMENTS HORIZONT AL TERMINA TION (FLEX) Regency ® Direct V ent System These venting systems, in combination with the P40 Direct V ent Gas Fireplace, have been tested and listed as a direct vent heater system by W arnock Hersey .
Regency ® P40-1 Direct V ent Gas Fireplace 15 INST ALLA TION INST ALLA TION RIGID PIPE VENTING SYSTEMS BASIC HORIZONT AL & VERTICAL TERMINA TIONS Rigid Pipe V ent Systems of fer a complete line of component parts for installation of both horizontal and vertical installations.
Regency ® P40-1 Direct V ent Gas Fireplace 16 INST ALLA TION INST ALLA TION Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ Metal-Fab ® Sure S.
Regency ® P40-1 Direct V ent Gas Fireplace 17 INST ALLA TION INST ALLA TION L676 & L900 Direct V ent Fireplace IMPORT ANT NOTE • A V ent Guard is required when the AstroCap is installed above grade at 7 feet or lower . • The Simpson Dura-V ent and Selkirk Direct T emp horizontal termination caps cannot be used in any applications.
Regency ® P40-1 Direct V ent Gas Fireplace 18 INST ALLA TION INST ALLA TION The diagram shows all allowable combinations of vertical runs with horizontal terminations, one 90 o elbow (two 45 o elbows equal one 90 o elbow). Note: Must use optional rigid pipe adapter (Part # 770-994) when using any Rigid V ent System (ie.
Regency ® P40-1 Direct V ent Gas Fireplace 19 INST ALLA TION INST ALLA TION H H1 V Horizontal V enting with T wo (2) 90 o Elbows Horizontal V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows. Option V H + H1 A) 2' Min.
Regency ® P40-1 Direct V ent Gas Fireplace 20 INST ALLA TION INST ALLA TION V H1 H V1 V1 V H V ertical V enting with T wo (2) 90 o Elbows V ertical V enting with Three (3) 90 o Elbows One 90 o elbow = T wo 45 o elbows. One 90 o elbow = T wo 45 o elbows.
Regency ® P40-1 Direct V ent Gas Fireplace 21 INST ALLA TION INST ALLA TION • V ent must be supported at offsets. • Firestops are required at each fl oor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances" section.
Regency ® P40-1 Direct V ent Gas Fireplace 22 INST ALLA TION INST ALLA TION Diagram 7 Diagram 6 10) Install wall thimble in the center of the 1 1" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 7) Insure that the 1-1/4"(32mm) pipe clearances to combustible materials are maintained (Diagram 5).
Regency ® P40-1 Direct V ent Gas Fireplace 23 INST ALLA TION INST ALLA TION 6) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet (0.9 meter), to avoid excessive stress on the elbows, and possible separation.
Regency ® P40-1 Direct V ent Gas Fireplace 24 INST ALLA TION INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency ® P40-1 Direct V ent Gas Fireplace 25 INST ALLA TION INST ALLA TION P40-NG1 SYSTEM DA T A For 0 to 4500 feet altitude Front Burner Ori fi ce: #44 Back Burner Ori fi ce: #35 Max. Input Rating 45,000 Btu/h Min. Input Rating 13,000 Btu/h Supply Pressure min.
Regency ® P40-1 Direct V ent Gas Fireplace 26 INST ALLA TION INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® P40-1 Direct V ent Gas Fireplace 27 INST ALLA TION INST ALLA TION CONVERSION KIT #502-969 FROM NG T O LP LP Conversion Kit Contains: Qty . Part # Description 1 910-462 LP Conversion Coil 1 .
Regency ® P40-1 Direct V ent Gas Fireplace 28 INST ALLA TION INST ALLA TION 14) Re-install pilot shield. 15) Set aeration on both front and rear burner for LP gas; Rear 3/16" Front 3/8" 16) Reverse steps 8 to 4. 17) Remove the Power Module by lifting it up off of the velcro and move it over to the side.
Regency ® P40-1 Direct V ent Gas Fireplace 29 INST ALLA TION INST ALLA TION CONVERSION KIT #502-966 FROM LP TO NG NG Conversion Kit Contains: Qty . Part # Description 1 910-463 NG Conversion Coil 1 9.
Regency ® P40-1 Direct V ent Gas Fireplace 30 INST ALLA TION INST ALLA TION 14) Re-install pilot shield. 15) Set aeration on both front and rear burner for LP gas; Rear 1/4" Front 1/8" 16) Reverse steps 8 to 4. 17) Remove the Power Module by lifting it up off of the velcro and move it over to the side.
Regency ® P40-1 Direct V ent Gas Fireplace 31 INST ALLA TION INST ALLA TION IMPORT ANT Dangerous operating conditions may occur if the panels are broken. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit.
Regency ® P40-1 Direct V ent Gas Fireplace 32 INST ALLA TION INST ALLA TION Read the instructions below carefully and refer to the pictures. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.
Regency ® P40-1 Direct V ent Gas Fireplace 33 INST ALLA TION INST ALLA TION 11 ) Place log 03-33 on the back burner in between the burner tubes. Slide the log to the left until it touches the end of the burner tube. 03-33 Burner Tu b e 10) Fit log 03-34 into the 1st log stand post and rest on the ember bed.
Regency ® P40-1 Direct V ent Gas Fireplace 34 INST ALLA TION INST ALLA TION 12) Place the bottom of log 03-46 onto the 2nd log stand post and fi t the top of log 03-46 into the pin on the left side of log 03-33. 13) Place the end of log 03-36 on the 3rd log stand post and fi t the top of log 03-36 into the pin on the right side of log 03-33.
Regency ® P40-1 Direct V ent Gas Fireplace 35 INST ALLA TION INST ALLA TION Completed Log Set Installation 03-37 03-36 03-46 03-34 03-32 03-47 03-40 03-38(1) 03-38(2) 16) Place one of log 03-38 on the exposed base brick on the left side of the unit as shown.
Regency ® P40-1 Direct V ent Gas Fireplace 36 INST ALLA TION INST ALLA TION Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR NOTE: Install Finishing T rim prior to installing the Flush Door and Louvers.
Regency ® P40-1 Direct V ent Gas Fireplace 37 INST ALLA TION INST ALLA TION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. A receptacle is provided on the left hand side of the unit.
Regency ® P40-1 Direct V ent Gas Fireplace 38 INST ALLA TION INST ALLA TION Leave these two screws secured Remove the center screw Loosen these four screws Leave these two screws secured Cut Outs Obl.
Regency ® P40-1 Direct V ent Gas Fireplace 39 INST ALLA TION INST ALLA TION Upper Air Register Simply push in the Full Screen Door Frame until it aligns against the fi nished wall. Secure T op Flange of Full Screen Door Frame as described in step 4b.
Regency ® P40-1 Direct V ent Gas Fireplace 40 OPERA TION OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency ® P40-1 Direct V ent Gas Fireplace 41 OPERA TION OPERA TING INSTRUCTIONS During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the fi lm will bake on and become very dif fi cult to remove.
Regency ® P40-1 Direct V ent Gas Fireplace 42 OPERA TION OPERA TING INSTRUCTIONS SUMMAR Y OF CONTROLS For the Manual Control Box, located on right hand side of the bottom louver . On/Off Button If the unit is off, pressing and releasing this button once will switch the unit on.
Regency ® P40-1 Direct V ent Gas Fireplace 43 OPERA TION OPERA TING INSTRUCTIONS COPY OF LIGHTING PLA TE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1) Push in gas control knob slightly and turn clockwise to “OFF”.
Regency ® P40-1 Direct V ent Gas Fireplace 44 MAINTENANCE MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® P40-1 Direct V ent Gas Fireplace 45 MAINTENANCE MAINTENANCE CAUTION: Wear gloves when removing damaged or broken glass. W ARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or quali fi ed service person.
Regency ® P40-1 Direct V ent Gas Fireplace 46 MAINTENANCE MAINTENANCE V AL VE REPLACEMENT 1) Shut off the main gas supply and unplug the power to the ECS system. 2) Remove the main gas line pipe from the gas valve. 3) Remove logs and brick panels if installed.
Regency ® P40-1 Direct V ent Gas Fireplace 47 MAINTENANCE MAINTENANCE 1) Unplug the power source. 2) Remove the manual control panel by removing the 2 screws. 3) Remove the DC Sparker by removing the 2 screws that secure the DC Sparker to the fi rebox and lift out.
Regency ® P40-1 Direct V ent Gas Fireplace 48 MAINTENANCE MAINTENANCE Power Module 3) Remove the Control Module by lifting it up off of the velcro and pull out. 1) Unplug the power source. 2) Remove the Power Module by lifting it up off of the velcro and pull out.
Regency ® P40-1 Direct V ent Gas Fireplace 49 P AR TS LIST P ARTS LIST MAIN ASSEMBL Y Part # Description 10) 502-528 Brick Panel Base (Set of 3) 502-901 Brick Panel Set Standard Brown 502-902 Brick P.
Regency ® P40-1 Direct V ent Gas Fireplace 50 P AR TS LIST P ARTS LIST 120 122 121 125 127 128 129 126 V AL VE TRA Y ASSEMBL Y Part # Description 120) 904-644 Ori fi ce # 35 121) 904-568 Ori fi ce .
Regency ® P40-1 Direct V ent Gas Fireplace 51 P AR TS LIST P ARTS LIST FLUSH DOOR & LOUVERS Part # Description 502-910 Flush Louvers (Set) - Black 133) * Flush Louver - T op 134) * Flush Louver -.
Regency ® P40-1 Direct V ent Gas Fireplace 52 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________.
Regency ® P40-1 Direct V ent Gas Fireplace 53 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________.
Regency ® P40-1 Direct V ent Gas Fireplace 54 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________.
Regency ® P40-1 Direct V ent Gas Fireplace 55 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
デバイスRegency P40-LP1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency P40-LP1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency P40-LP1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency P40-LP1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency P40-LP1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency P40-LP1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency P40-LP1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency P40-LP1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency P40-LP1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。