FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-177c MODELS: P48-NG Natural Gas P48-LP Propane P48 Gas Fireplace WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P48 has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 3 T ABLE OF CONTENTS Flush Trim ................................................................. 2 8 Bay Door ................................................................... 2 9 Bay Trim ......
Regency P48 Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each P48-NG and P48-LP Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when the bottom louver is open.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 5 INST ALLA TION IMPORT ANT : SA VE THESE INSTRUCTIONS The P48-NG /P48-LP Direct Vent Fireplace must be installed in accordance with these instruc- tions. Carefully read all the instructions in this manual first.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 6 INST ALLA TION Diagram 1 UNIT SPECIFICA TIONS This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 51,000 (NG) Btu/h, 48,000 (LP) Btu/h) after burning ap- pliance for 15 minutes.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 7 INST ALLA TION The HeatWave Duct Kit and the Heat Release Kit have different clear- ance and framin require- ments, check the Heat- Wave and Heat Release manual for details.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 8 MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver are shown in the diagram below.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 9 INST ALLA TION Note: 43" (1092mm) is the minimum height for flex termination and Simpson Dura-Vent terminations. Diagram 1 1) Determine the total thickness of facing material (eg. drywall plus ceramic tiles) to allow the finished surface to be flush with the front of the unit.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 10 VENTING INTRODUCTION The P48 uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the .
Regency P48 Zero Clearance Direct Vent Gas Fireplace 11 INST ALLA TION EXTERIOR VENT TERMINA TION REQUIREMENTS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 12 VENTING Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P48 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 13 INST ALLA TION SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 14 INST ALLA TION VENTING ARRANGEMENTS - HORIZONT AL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and REGENCY DIRECT VENT SYSTEM (FLEX) (P.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 15 INST ALLA TION Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 1' Min. 3' Max. B) 2' Min. 4' Max. C) 3' Min. 5' Max. D) 4' Min. 6' Max. E) 5' Min.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 16 INST ALLA TION Horizontal Venting with Three (3) 90 o Elbows Option V H V + V 1 H + H1 A) 2' Min. 1' Max. 3' Min. 4' Max. B) 3' Min. 2' Max. 4' Min. 5' Max.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 17 INST ALLA TION Vertical Venting with Three (3) 90 o Elbows Option V H + H1 V + V1 A) 2' Min. 3' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max. 7' Min.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 18 INST ALLA TION • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).
Regency P48 Zero Clearance Direct Vent Gas Fireplace 19 INST ALLA TION The P48 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas, as per diagram.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 20 Diagram 7 Diagram 6 9) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 6 ) The arrow on the vent cap should be pointing up. Insure that the 1-1/4"(32mm) clearances to combustible materials are maintained (Diagram 5).
Regency P48 Zero Clearance Direct Vent Gas Fireplace 21 INST ALLA TION 6) Continue to assemble pipe lengths. Note: If a n offset is necessary in the attic to avoid obstructions, it is impor- tant to support the vent pipe every 3 feet (0.9 meter), to avoid exces- sive stress on the elbows, and possible separation.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 22 INST ALLA TION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 23 INST ALLA TION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 24 BRICK P ANELS INST ALLA TION INST ALLA TION 1) Unhook the 2 spring loaded hooks from the bottom of the flush door and lift the Flush Front off the unit. 2) Unwrap the brick pattern panels from the protective wrapping.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 25 Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 26 INST ALLA TION 7 ) Place Log 02-83 onto the pin in Log 02-88 and position the notch on the bottom of the log into the 4th grate post. 6 ) Embers should be placed in front of Log 02-85 and Log 02-86.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 27 INST ALLA TION 10 ) Place Log 02-90 onto the right side of the grate. Position the cut-out on the underside of the log onto the grate bar. Cut-out on the underside of the log. Position the cut-out onto the grate bar.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 28 INST ALLA TION Diagram 1 Diagram 3 ST ANDARD FLUSH DOOR The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 29 BA Y LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fitted louver leaves a small gap between faceplate bottom and louver top.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 30 OPTIONAL FINISHING TRIM NOTE: Remove both the Flush Louvers or Bay Louvers and the Flush Front or Bay Front prior to installing the Finishing Trim. 1) Install the Finishing Trim sides as shown in the diagram, line up the holes in the side trim with the holes in the firebox side.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 31 Can be used with Option 1 or 3 but not both. 1) Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 32 INST ALLA TION WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. No electrical power supply is required for the gas control to operate.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 33 INST ALLA TION INST ALLING THE OPTIONAL F AN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 34 CONVERSION KIT FROM NA TURAL GAS T O PROP ANE MODEL #370-969 FOR P48 USING SIT 820 NOV A GAS VAL VE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 5) Pull off the pilot cap to expose the pilot orifice.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 35 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 36 Copy of the Lighting Plate Instructions NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 37 LOG REPLACEMENT The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door and carefully remove the logs. (The pilot light generates enough heat to burn someone.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 38 CAUTION: Wear gloves when re- moving damaged or broken glass. Bay Glass Replacement 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Remove the nuts holding the glass clips in place and remove.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 39 MAINTENANCE 6) Remove the burner by removing the screw on the left side and then slide the burner to the left and lift out. 7) Remove the right and left side deflectors by removing the 2 screws on each deflector.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 40 P ARTS LIST P48 MAIN ASSEMBL Y Part # Description Part # Description 1 ) 948-259 Door Handle 3 ) 948-046 Chain 4 ) 948-115 Spring 6 ) 430-129 Re.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 41 P ARTS LIST HEA T RELEASE DUCT KIT 42 48 49 46 24 105 106 101 20 21 21 24 27 30 28 30 29 50 23 23 22 97 98 100 99 95 96 93 89 92 90 102 91 93 94.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 42 P ARTS LIST P48 BURNER & LOG ASSEMBL Y Part # Description 370-574/P Valve Assembly - Natural Gas 370-576/P Valve Assembly - Propane 52 ) * Gasket - Valve Access Plate 56) 910-190 Pi ezo Ig nito r & Nu t 57) 910-378 Valve S.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 43 P ARTS LIST P48 FLUSH DOOR & LOUVERS Part # Description Part # Description 370-925 Flush Louvers (Set) - Steel/Black 370-924 Flush Louvers (.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 44 P ARTS LIST P48 BA Y FRONT & LOUVERS 370-931 Bay Front Complete with Glass & Black Trim 370-932 Bay Front Screen & Black Trim 106) 9.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 45 NOTES _____________________________________________________________________________________ ____________________________________________________.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 46 NOTES _____________________________________________________________________________________ ____________________________________________________.
Regency P48 Zero Clearance Direct Vent Gas Fireplace 47 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility.
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Instal.
デバイスRegency P48-NGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Regency P48-NGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRegency P48-NGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Regency P48-NGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Regency P48-NGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Regency P48-NGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRegency P48-NGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Regency P48-NGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRegency P48-NGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。