1445 North HIghway Colville, W A 991 14 SA VE THESE INSTRUCTIONS INST ALLA TION, VENTING , OPERA TION AND MAINTENANCE MANUAL FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
REMINGTON QFP40 Direct V ent FIREPLACE Page 2 250-4721 JUNE 2001 Aladdin Hearth Products welcomes you to our tradition of excellence! In choosing a Quadra- Fire appliance, you have our assurance of commitment to quality , durability , and performance.
Page 3 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 MODEL NAME Q uadra Fire REMINGTON QFP40 SERIAL NUMBER L ocated on front, lower ledge of control panel.
REMINGTON QFP40 Direct V ent FIREPLACE Page 4 250-4721 JUNE 2001 CONTENTS CONTENTS SAFETY & CLEARANCES: Ratings Plate ................................................................................................. 6 S tandards Listing & Clearances Label .
Page 5 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 CONTENTS COMPLETING INST ALLA TION: Gas Line Requirements ................................................................................ 46 Electrical Connection ......................
REMINGTON QFP40 Direct V ent FIREPLACE Page 6 250-4721 JUNE 2001 1999 2000 2001 JAN FEB MAR MA Y JUN JUL AU G SE P O CT NOV DEC SAFETY LABEL Location: Serial No. portion on lip below control panel. Lower portion behind access door on baseplate to right of control panel.
Page 7 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Install fireplace in accordance with all local codes, if any; if none, follow The National Fuel Gas Codes ANSI Z223.
REMINGTON QFP40 Direct V ent FIREPLACE Page 8 250-4721 JUNE 2001 W ARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational pro- cedures.
Page 9 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 SAFETY NOTICES IF YOU SMELL GAS! ☛ Do not light any appliance ☛ Extinguish any open flame ☛ Do not touch any electrical switch or.
REMINGTON QFP40 Direct V ent FIREPLACE Page 10 250-4721 JUNE 2001 ZC APPL IANCE DIMENSIONS 29 1/16" 41" 45 4" 7" 1" Gas Inlet - 1 1/4" above base of unit, ac cess ible from either side.
Page 11 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 SPECIFICA TIONS MINIMUM CABINET DIMENSIONS Width 54 9/16" Depth 20 1/2" Height 56 1/2" Minimum 1/2" trim.
REMINGTON QFP40 Direct V ent FIREPLACE Page 12 250-4721 JUNE 2001 Access Door Mantel Fascia Framing Simpson-DuraVent V enting ZC Appliance Combustible Wall (See Clearances, Page 7) Gas line Electrical line Horizontal T ermination Cap INST ALLA TION TERMINOLOGY DuraRock, Tile, etc.
Page 13 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 AN OVERVIEW: INST ALLA TION TO OPERA TION 1. Remove door by releasing four spring clips (2 upper and 2 lower). See Pg. 53. 2. Remove logset, lava rock, embers and packaging materials from firebox.
REMINGTON QFP40 Direct V ent FIREPLACE Page 14 250-4721 JUNE 2001 NOTE: If converting this unit to prop ane, do so at this point of installation. LP CONVERSION INSTRUCTIONS Part # 842-4470 is required for this procedure. CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND TURN OFF GAS SUPPL Y TO UNIT BEFORE PROCEEDING .
Page 15 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Burner Orifice Replacement 5. If logset is installed, remove logs and embers at this time. 6. Use a Phillips screwdriver to remove pilot lighting channel and front log rack. 7. Remove the two Phillips head screws that secure the front and rear burner pans in place.
REMINGTON QFP40 Direct V ent FIREPLACE Page 16 250-4721 JUNE 2001 INST ALLA TION MINIMUM FRAMING DIMENSIONS ❖ The 1/2" stand-offs on the back and sides and 4" stand-offs on the top of the fireplace separate the fireplace from the framing members (see page 12, Installation T erminology).
Page 17 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION CORNER INST ALLA TIONS The usual 45º installation uses the minimum framing dimensions shown in the illustration below . PLEASE NOTE: All clearances as referenced on page 7 still apply .
REMINGTON QFP40 Direct V ent FIREPLACE Page 18 250-4721 JUNE 2001 INST ALLA TION RAISED FIREPLACE The fireplace and it’s hearth, if desired, may be placed on a platform designed to support the fireplace weight (240lbs.
Page 19 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION Raised Plat form Raised Hearth RAISED FIREPLACE WITH RAISED HEARTH.
REMINGTON QFP40 Direct V ent FIREPLACE Page 20 250-4721 JUNE 2001 INST ALLA TION HEARTH REQUIREMENTS No clearances to combustible flooring are required for installation of the Remington QFP40, as referenced in the Clearances to Combustibles on page 7 of this manual.
Page 21 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION MANTEL REQUIREMENTS COMBUSTIBLE MANTELS As referenced on page 7, Clearance to Combustible Materials: The allowable height from the top of the glass to the lower edge of a maximum mantel depth of 12", is 30 1/2".
REMINGTON QFP40 Direct V ent FIREPLACE Page 22 250-4721 JUNE 2001 F ASCIA DIMENSIONS ARCHED Part #841-0710 Gold Part #841-0750 Brushed Nickel Part #841-0720 Black 40 1/ 2" R53 7/ 16" 31".
Page 23 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 RECT ANGULAR 40 3/4" 31" 17 1/2" 31 1/2" 7 3/8" INST ALLA TION F ASCIA DIMENSIONS Part #841-0730 Black.
REMINGTON QFP40 Direct V ent FIREPLACE Page 24 250-4721 JUNE 2001 INST ALLA TION F ACING REQUIREMENTS HEADER NON- COMBUSTIBLE F ACING 3" MIN. FOR ARCHED or RECT ANGULAR F ASCIA Durarock or other non-combustible material must extend from header to floor and to framing on either side.
Page 25 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION F ACING OVER 1” (25 mm) THICK Facing material greater than 1" (25mm) thick, such as brick, river rock, etc., will require installation around the perimeter of the face.
REMINGTON QFP40 Direct V ent FIREPLACE Page 26 250-4721 JUNE 2001 VENTING GENERAL VENTING INSTRUCTIONS PLEASE NOTE: In order to comply with applicable codes and product warranties, only Simpson Dura-V ent venting components may be used. DO NOT USE FIELD-F ABRICA TED VENTING COMPONENTS.
Page 27 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 VENTING SIMPSON DURA-VENT P ARTS LIST Simpson Dura-V ent offers a complete line of component parts for installation in both horizontal and vertical applications. Many items are offered in decorative black, as well as a galvanized finish.
REMINGTON QFP40 Direct V ent FIREPLACE Page 28 250-4721 JUNE 2001 VENTING VENTING INST ALLA TION OPTIONS & GUIDELINES There are four types of direct vent system installations approved for use with the REMINGTON QFP40. It is very important to maintain a balance between the combustion air intake and the flue gas exhaust venting system.
Page 29 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 VENTING FIG . 1 HORIZONT AL TERMINA TION TERMINA TION CAP REQUIREMENTS: ON HORIZONT AL TERMINA TIONS USE ONL Y DURA VENT P ART # 985, OR ALADDIN HEARTH PRODUCTS P ART #HHW2 VERTICAL TERMINA TIONS USE ONL Y DURA VENT P ART #991.
REMINGTON QFP40 Direct V ent FIREPLACE Page 30 250-4721 JUNE 2001 FIG . 3 INST ALLA TION INTO A CLASS A MET AL CHIMNEY (USA ONL Y) VENTING INST ALLA TION, CONT .
Page 31 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 FIG . 4 INST ALLA TION INTO A MASONR Y CHIMNEY (USA ONL Y) DuraV ent #991 High Wind T ermination Cap ONL Y T op Adapter Flashing Direct V ent Pipe Retro Connector 4" Flex Liner VENTING INST ALLA TION, CONT .
REMINGTON QFP40 Direct V ent FIREPLACE Page 32 250-4721 JUNE 2001 VENTING HOW TO USE VENT GRAPH TOT A L HORIZONT A L RUN TO OUTSIDE OF EXTE RIOR W A LL (EX CLUDI NG EL BOWS) 2' 4' 6' 8&.
Page 33 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 A Ope na ble Fixed Closed B C F G H I A V V V V K A J M N V = vent term inal A = air supply inle t HORIZONT AL TERMINA TION REQUIREMENTS VENTING A. *12” (30cm) minimum: Clearance above grade, veranda, porch, deck, or balcony .
REMINGTON QFP40 Direct V ent FIREPLACE Page 34 250-4721 JUNE 2001 Step 1. Determine the desired location of the fireplace. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust the location of the stove.
Page 35 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Step 3. With the adapter , any vertical pipe required for your installation, and the 90° elbow attached to the flue outlet, measure t.
REMINGTON QFP40 Direct V ent FIREPLACE Page 36 250-4721 JUNE 2001 HORIZONT A L INST ALLA TION (CONT .) Step 4. Position the horizontal vent termination in the center of the 10" (254mm) square hol.
Page 37 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Step 5. Slide the stove and vent assembly (see Fig. 9 below) towards the wall, carefully inserting the vent pipe into the vent cap assembly . It is important that the vent pipe extend into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1¼" (32mm).
REMINGTON QFP40 Direct V ent FIREPLACE Page 38 250-4721 JUNE 2001 VERTICAL INST ALLA TION INSTRUCTIONS USING GS SERIES PIPE Step 1. Check the installation instructions for required 1" clearances (air space) to com- bustibles when p assing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.
Page 39 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 1 - 1/ 2" Lon g W oo d S cr ew s C e ili ng J o i sts Fr a m in g Step 4. Assemble the desired lengths of GS pipe and elbows necessary to reach from the stove up through the round support box.
REMINGTON QFP40 Direct V ent FIREPLACE Page 40 250-4721 JUNE 2001 VERTICAL INST ALLA TION INSTRUCTIONS (CONT .) USING GS SERIES PIPE ( CONT .) Step 7. Continue to assemble pipe sections until the heig.
Page 41 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 VERTICAL INST ALLA TION INSTRUCTIONS (CONT .) CA THEDRAL CEILING INST ALLA TION Step 1.
REMINGTON QFP40 Direct V ent FIREPLACE Page 42 250-4721 JUNE 2001 VERTICAL INST ALLA TION INSTRUCTIONS (CONT .) INST ALLA TION INTO A CLASS A MET AL CHIMNEY (USA ONL Y) NOTE: Have the existing installation inspected by a qualified chimney sweep or profes- sional installer prior to converting to direct vent.
Page 43 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 VERTICAL INST ALLA TION INSTRUCTIONS (CONT .) INST ALLA TION INTO AN EXISTING MASONR Y CHIMNEY (USA ONL Y) Step 1. Before cutting any holes, assemble the desired sections of direct vent pipe to determine the center of the masonry penetration.
REMINGTON QFP40 Direct V ent FIREPLACE Page 44 250-4721 JUNE 2001 Step 5. Connect the flex liner to the top adapter using three sheet metal screws (see Fig- ure 19, page 42).
Page 45 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Step 9. Attach the flex to the retro connector . Use three sheet metal screws to attach the flex liner to the connector (Figure 26). Mount the retro connector to the ma- sonry wall using masonry bolts.
REMINGTON QFP40 Direct V ent FIREPLACE Page 46 250-4721 JUNE 2001 GAS LINE REQUIREMENTS ✔ The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.
Page 47 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 ELECTRICAL CONNECTION Make sure the household breaker is shut off prior to working on any electrical lines.
REMINGTON QFP40 Direct V ent FIREPLACE Page 48 250-4721 JUNE 2001 . 1. Place rear brick behind log rack against rear wall of firebox as shown in Fig. 1. NOTE: BRICK IS FRAGILE. HANDLE WITH CARE. Inst allation of the brick set should be made prior to the logset, nugget and lava rock inst allation.
Page 49 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 3. Attach brick retaining clip s to right and left sides, using mounting screws removed in Step 2. (Fig. 4). FIG . 3 FIG . 4 BRICK INST ALL BRICK INST ALLA TION, CONT . Mounting screw & clip placement.
REMINGTON QFP40 Direct V ent FIREPLACE Page 50 250-4721 JUNE 2001 1. Install complete bag of lavarock in indicated gray area ONL Y shown in Figs. 1 & 2. LOGSET AND NUGGET INST ALLA TION NOTE: If you plan to inst all the optional brick set, do so prior to inst alling the logset, nugget s and lava rock.
Page 51 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 LOGSET AND NUGGET INST ALLA TION, CONT . 3. Set Rear Log in rear log bracket with pegs in upright position. Fig. 3. 4. Set the notch in the Front Log over the pilot transfer channel and center log side-to-side on the grate with pegs in upright position.
REMINGTON QFP40 Direct V ent FIREPLACE Page 52 250-4721 JUNE 2001 LOGSET AND NUGGET INST ALLA TION, CONT . LOGSET INST ALL 5. Place Left T wig onto pegs on top of Rear and Front Logs. Fig. 5. 6. Place Right T wig onto pegs on top of Rear and Front Logs.
Page 53 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 All arched and rectangular fascia attach to four flanges located two to each side of the glass frame. Insert and finger start bolts tightening with the 5/32" Allen wrench supplied with unit.
REMINGTON QFP40 Direct V ent FIREPLACE Page 54 250-4721 JUNE 2001 LEAK TEST 1. T urn on gas to the fireplace. 2. T urn on gas at the manual shutoff valve. 3. Leak test all gas joints prior to starting the appliance. 4. Familiarize yourself with the control panel components, see page 58.
Page 55 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 LIGHTING INSTRUCTIONS LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
REMINGTON QFP40 Direct V ent FIREPLACE Page 56 250-4721 JUNE 2001 ADJUSTMENTS ADJUSTING THE BLOWER SPEED The blower will turn on automatically within approximately 10 minutes after start-up and the fireplace is up to temperature. This aids in transferring the heat into the living area.
Page 57 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 ADJUSTMENTS HIGH AL TITUDE OPERA TION In Canada, this unit is approved from 0 to 4500 feet above sea level. Installation of this stove at altitudes above 4500 feet is subject to field test of the individual inst allation and approval by the local authority having jurisdiction.
REMINGTON QFP40 Direct V ent FIREPLACE Page 58 250-4721 JUNE 2001 OPERA TION Read this entire manual prior to using the fireplace. Pay particular attention to the “Safety Precautions” section on pages 6-9. Failure to follow the instructions may result in prop- erty damage, bodily injury , or even death.
Page 59 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 MAINTENANCE GENERAL Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person.
REMINGTON QFP40 Direct V ent FIREPLACE Page 60 250-4721 JUNE 2001 YEARL Y SERVICING PROCEDURES W ARNING! Failure to inspect and maintain the fireplace may lead to improper com- bustion and a potentially dangerous situation.
Page 61 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 Replace glass with part #842-3820 ONL Y , available from your dealer . 1. T urn valve to “OFF” position to prevent start-up of unit while door is removed.
REMINGTON QFP40 Direct V ent FIREPLACE Page 62 250-4721 JUNE 2001 MAINTENANCE BLOWER REPLACEMENT Part #842-3790 1. Disconnect power to unit at power supply (this may require shutting off power at the circuit breaker box). 2. Remove fascia and door . 3.
Page 63 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 MAINTENANCE ELECTRICAL SCHEMA TIC.
REMINGTON QFP40 Direct V ent FIREPLACE Page 64 250-4721 JUNE 2001 TROUBLESHOOTING Pilot won’t light ✔ Is a gas shut-off valve turned on? ✔ Is the valve control knob turned to “PILOT” (See Lighting Instructions, #7, Pg.
Page 65 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 TROUBLESHOOTING , (CONT .) Fireplace Design: Many of the components within this fireplace are designed specifically for safety purposes. I t i s therefore imperative that only certified gas service technicians should service this fireplace.
REMINGTON QFP40 Direct V ent FIREPLACE Page 66 250-4721 JUNE 2001 P ARTS & ACCESSORIES PA R T S 842-0240 V alve (NG) 842-3501 Pilot 842-3910 Pilot Orifice NG (.
Page 67 REMINGTON QFP40 Direct V ent FIREPLACE 250-4721 JUNE 2001 W ARRANTY GAS APPLIANCE LIMITED LIFETIME WARRANTY Aladdin Hearth Products, warrants this gas heating appliance to the original purchaser for the lifetime of the appliance, to be free from defects in material and workmanship.
REMINGT ON QFP40 Direct V ent Gas Fireplace Owner ’ s Manual.
デバイスRemington QFP40の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Remington QFP40をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRemington QFP40の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Remington QFP40の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Remington QFP40で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Remington QFP40を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRemington QFP40の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Remington QFP40に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRemington QFP40デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。