RemingtonメーカーREMJ150の使用説明書/サービス説明書
ページ先へ移動 of 24
PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL 150 SIDE HANDLE PFA/PV 005 REMJ150 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
2 102961 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ..........................................
3 102961 SAFETY INFORMA TION Continued W ARNINGS (Continued) • Use only kerosene to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
4 102961 Side Cover PRODUCT IDENTIFICA TION Figure 1 - REMJ70 Fan Guard Power Cord Fuel Cap Fan Guard Hot Air Outlet Upper Shell Fuel Tank Lower Shell Fuel Gauge Flame-Out Control Reset Button ON/OFF .
5 102961 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y These models are furnished with wheels and handles.
6 102961 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
7 102961 W ARNING Review and understand the warnings in the Safety Information Section , page 3. They are needed to safely operate this heater. Follow all local codes when using this heater. OPERA TION To Start Heater 1. Follow all ventilation and safety information.
8 102961 To Stop Heater 1. Turn ON/OFF switch to “OFF.” 2. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater , page 7. Note: If shipping, transport companies require fuel tanks to be empty.
9 102961 TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, air intake, and lint filters Dirty fuel filter Dirt in nozzle Dirty photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time See Pump Pressure Adjustment , page 12.
10 102961 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Figure 9 - Fuel Filter Removal (REMJ70) Side Cover Fuel Filter (REMJ70) 1.
11 102961 Fuel Filter (REMJ150) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. Wash fuel filter with clean fuel and replace in tank.
12 102961 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).
13 102961 Nozzle 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6.
14 102961 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut- driver.
15 102961 REMJ70 REMJ150 Heat Output (Kcal/hr) 17,640 38,500 Fuel Consumption (liters/hr) 1.9 4.2 Fuel T ank Capacity (liters) 16 47 Run T ime per T ank (hours) 8 11 Hot Air Output (m 3 /min) 6.7@50Hz 12.4@50Hz 7.5@60Hz 13.7@60Hz V oltage 100 100 Frequency (Hz) 50/60 50/60 W attage (W) 200 340 Pump Pressure (kg/cm 2 ) 0.
16 102961 ILLUSTRA TED P ARTS BREAKDOWN REMJ70 18-2 Motor and Pump Assembly 18-5 18-16 18-4 18-8 18-3 18-6 18-7 18-9 18-10 18-11 18-12 18-13 18-14 18-15 10-2 10-3 10-4 10-5 10-6 10-7 10-1 18-1 18-18 B.
17 102961 KEY PART PART NO. NUMBER DESCRIPTION QTY. 19 M50050 Rubber Boot 1 20 NTC-4C Hex locknut 2 21 M50104-02 Shorty Bushing (wires) 1 22 M11084-26 Screw, #10-16 x 3/8" 6 23 098511-81 Lower Sh.
18 102961 10-2 10-11 Motor and Pump Assembly 10-1 10-4 10-3 10-5 10-6 10-7 10-8 10-9 10-10 10-12 10-13 10-14 10-15 10-16 10-17 10-18 BURNER HEAD 100 EAI/EBI PFA/P 022 Burner Head Assembly 7-1 7-2 7-3 .
19 102961 17 101901-03 Electronic Ignitor 1 18 M11084-29 Screw, #10-16 x 3/4" 2 19 M51345-01 Fuel Line 1 20 M51150-01 Fuel Filter 1 21 M51151-02 Fuel Line Tube 1 22 M10990-3 Rubber Bushing 1 23 M.
20 102961 WHEELS AND HANDLES 3 6 5 7 2 4 1 7 4 3 5 6 1 2 REMJ70 REMJ150 KEY PART PART REMJ70 REMJ150 NO. NUMBER DESCRIPTION QTY. QTY. 1 097198-02 Handle (Rear) 1 — 097777-03 Handles — 2 2 M12345-3.
21 102961 WIRING DIAGRAMS White Photo- cell Black Blue Flame Out Control B Reset Button R Red Blue White Spark Plug Green/ Yellow Black Power Plug Green White White White Red Red Green Terminal Board Motor Ignitor Plug Receptacle Power On Switch Black Red Relay Black ACCESSOR Y Purchase accessory from your local dealer.
22 102961 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
23 102961 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
24 102961 Printed in U.S.A. 102961-01 Rev. A 06/96.
デバイスRemington REMJ150の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Remington REMJ150をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはRemington REMJ150の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Remington REMJ150の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Remington REMJ150で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Remington REMJ150を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はRemington REMJ150の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Remington REMJ150に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちRemington REMJ150デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。