Document MR0012




Information contained in this publication is subject to change. In the event of changes, the publication will be revised. Comments concerning its contents should be directed to:
Nearline Information Development Storage Technology Corporation One StorageTek Drive Louisville, CO 80028-2201 USA
© 1995 through 1999, Storage Technology Corporation, Louisville, CO, USA. All rights reserved.
ii 9710 System Assurance Guide MR0012J

Total number of pages in this document is 86, consisting of the following:
Pages Disposition Cover Replace entire manual Blank page Title page Copyright page (ii) iii through xiv 1-1 through 1-6 2-1 through 2-4 3-1 through 3-12 4-1 through 4-30 5-1 through 5-4 A-1 through A-6 Index-1 through Index-2 Reader’s Comment Form Business Reply Mailer Blank Page Back Cover
MR0012J 9710 System Assurance Guide iii

Date Reissue Level Change
Dec. 1999 J throughout: Incorporated template 103199 and updated boilerplate. Changed personnel references to reflect new Customer Service organization. Indicated support of 9840 Fibre Channel drives. Chapter 3: Removed note about AS/400 not supporting 9840 or DLT drives. Added host interface graphics (Figure 3- 2 through 3-6). Added illustration of I/O panel that shows Fibre Channel plate in lower left corner. Chapter 4: Expanded power cable table with new power cable part numbers. Corrected drawing of Centronics 50-pin connector. Added new in-country media services telephone numbers. Added note clarifying feature codes 1603 and 2016. Appendix A: Updated weight specifications.
iv 9710 System Assurance Guide MR0012J


Figure 1-1. The System Assurance Overview 1-1 Figure 1-2. The System Assurance Process Flow 1-4 Figure 3-1. 9710 LSM with Expansion Door 3-1 Figure 3-2. Direct Connection for AS/400 Control 3-4 Figure 3-3. Client Configuration (Indirect Connection) with AS/400 3-5 Figure 3-4. SCSI Direct Connection (Open Systems) with Common Bus 3-6 Figure 3-5. Host-Indirect Connection 3-7 Figure 3-6. Subsystem Generic Software Types 3-8 Figure 3-7. 9710 I/O Panel (Showing FIPS) 3-11 Figure 3-8. 9710 I/O Panel (Showing Fibre Channel) 3-12 Figure 4-1. 9710 Model/Feature Selections 4-3 Figure 4-2. DLT8000 Model and Feature Selections 4-5 Figure 4-3. DLT7000 Feature Selections 4-6 Figure 4-4. DLT4000 Feature Selections 4-7 Figure 4-5. 4890 Drive Feature Selections 4-8 Figure 4-6. SCSI Connector Types 4-12 Figure 4-7. FIPS AS/400 Cabling Configurations 4-24 Figure A-1. 9710 Layout and Floor Space Requirements A-3
viii 9710 System Assurance Guide MR0012J

Table 1-1. Team Member Responsibilities 1-2 Table 4-1. PDU Cables 4-9 Table 4-2. Serial Cables, 9710 to Host 4-10 Table 4-3. SCSI Cable Restriction 4-11 Table 4-4. SCSI Cable Length Subtraction 4-13 Table 4-5. SCSI Cables 9710 to Host 4-15 Table 4-6. Specialized Daisy Chain Cables 4-16 Table 4-7. Daisy Chain Terminators 4-16 Table 4-8. PRS Card Cables 4-17 Table 4-9. Robotics Control Cables, Internal 4-18 Table 4-10. SCSI Cables and Adapters for AS/400 Path 4-19 Table 4-11. SCSI Cables and Adapters for Sun Sparc Workstation 4-20 Table 4-12. SCSI Cables and Adapters for RS/6000 and Bull DPX/20 4-21 Table 4-13. Adapters, SCSI 4-22 Table 4-14. Single-Ended Narrow or Fast/Narrow to Wide SCSI 4-22 Table 4-15. High Density 68-68 Pin Jackscrew SCSI 4-22 Table 4-16. AS/400 Serial Cables 4-23 Table 4-17. Sequent Cables 4-23 Table 4-18. FIPS Cables 4-25 Table 4-19. FIPS Terminators 4-26 Table 4-20. FIPS Cables 4-26 Table 4-21. Modem Cables 4-27 Table 4-22. Remote Diagnostic Support for PC Use 4-27 Table 4-23. In-Country Media Supply Services 4-28 Table 5-1. Pre-installation Checklist 5-1 Table 5-2. Remote Support Hardware and Cables 5-2 Table A-1. 9710 Dimensions and Weights A-1 Table A-2. LSM Power Specifications A-1 Table A-3. Optional Power Distribution Unit (PDU) Specifications A-2 Table A-4. LSM Environmental Specifications A-2 Table A-5. Power Characteristics A-4
MR0012J 9710 System Assurance Guide ix

This page intentionally left blank.
x 9710 System Assurance Guide MR0012J
Tables

This guide contains information about planning, ordering, installing, and follow-up activities required during StorageTek TimberWolf 9710 Library Storage Module sales, delivery, and installation.
The audience for this guide includes StorageTek marketing representatives, solutions delivery systems specialists (SDSSs), ssolutions delivery installation consultants (SDICs), solutions delivery engineers (SDEs), independent consultants, service representatives, and customers involved with installation planning.
This guide provides a series of worksheets and checklists that, when completed properly, ensure that no aspect of the installation process has been overlooked. This promotes error-free installation and customer satisfaction. Use only those checklists that are applicable to your system. However, certain worksheets (noted below) must be completed for the product to be shipped. Refer to Chapter 4 for more information.
Administration, the product will not be shipped.
This guide contains the following information:
Chapter 1 “The System Assurance Process” provides detailed information useful for understanding the System Assurance process.
Chapter 2 “Key Personnel” provides a worksheet for recording names and phone numbers of the key personnel on the system assurance teams.
Chapter 3 “Product Overview” provides an overview of the LSM, drive configurations, and interfaces
Chapter 4 “Ordering the Equipment” contains worksheets to complete when ordering the 9710 Library
MR0012J 9710 System Assurance Guide xi

Chapter 5 “Pre-installation Checklist” provides checklists to ensure no unresolved issues exist at installation.
Appendix A “Site Planning Information” provides LSM specifications and floor space layout.
Index The Index assists in locating information in this publication.
StorageTek is a trademark of Storage Technology Corporation. Other features and terms used in this publication are for informational purposes only and might be trademarks of Storage Technology Corporation or other companies.
Typographical conventions highlight special words, phrases, and actions used in this publication.
Button MENU Physical buttons or switches, onscreen buttons, and softkeys appear in Helvetica font and in all capital letters.
not or must Important or emphasized words and phrases appear in italics.
Filenames dictionary.txt Filenames appear in Courier font.
Open Indicators and LEDs appear with initial capital letters and in italics.
Keyboard keys [Y], [Enter] or [Ctrl+Alt+Delete]
Keyboard keys appear within brackets, in Helvetica font, with initial capital letters or as the key appears on the keyboard.
downloading Screen captures or messages appear in Courier font.
Screen captures or messages
Device = xx Names of variables that require values assigned appear in italics.
Pathnames P:\Printshp\Pubs or home/gandalf/litdist
Pathnames appear in Courier font.
Positions for switches, jumpers, and circuit breakers
ON Switch, jumper, and circuit breaker positions appear in default font and all capital letters.
xii 9710 System Assurance Guide MR0012J

URLs and hypertext links
www.stortek.com/techpubs Universal Resource Locator (URL) and hypertext links appear in blue text and underlined.
Additional information is contained in the following publications:
9710 Publication Part Number
9710 Library Storage Module Installation Manual 9640
Quantum™ DLT Publications Part Number DLT4000 Cartridge Subsystem Product Manual 313127601 (StorageTek) 81-60043-0x (Quantum)
DLT7000 Tape Drive Product Manual 313134501 (StorageTek) 81-60000-0x
DLT8000 Tape Drive Product Manual 81-60118-0x (Quantum)
9840 Publications Part Number 9840 Tape Drive System Assurance Guide MT 5003 9840 Tape Drive Installation Manual 95879
4890 Publications Part Number 4890 Maintenance Manual 9512952900 4890 Product Manual 9512941000
You may have access to the following additional sources of information.
StorageTek’s Customer Resource Center (CRC) is an online service that provides technical information such as software publications, user documentation, maintenance fixes, and answers to frequently asked questions. The CRC is for
MR0012J 9710 System Assurance Guide xiii
Preface · Item Example Description

StorageTek employees and for contract customers and partners with a login and password.
The location of the CRC is http://www.support.storagetek.com
Documents on CD is a compact disc that contains portable document format (PDF) files of StorageTek’s tape, library, and OPENstorage disk publications. This CD is for StorageTek employees only. Contact the Logistics Depot to order the CD or get onto the distribution list.
StorageTek’s Electronic Document Center (EDC) is an online service that provides links to technical publications about StorageTek products, pre-sales planning, and strategic tools. The EDC is for StorageTek employees only.
The location of the EDC is http://gandalf.stortek.com/dynaweb/prod
StorageTek’s KnowledgeMap is an online service that provides product information, general resources, white papers, and answers to frequently asked questions. It also contains information about networks, platforms, and sales support. The KnowledgeMap is for StorageTek employees and distributors.
The location of the KnowledgeMap is http://wwfokm.stortek.com/
StorageTek’s Partners Page is an online service that provides information about events, education, products, and connectivity. The Partners Page is for StorageTek employees and partners with a login and password.
The location of the Partners Page is http://www.storagetek.com/Partners/
The Storefront is StorageTek’s external web site. The Storefront provides information about topics such as news bulletins, products, services, integrated solutions, customer support, and upcoming events. The storefront is accessible to all persons with a web browser.
The location of the Storefront is http://www.storagetek.com
xiv 9710 System Assurance Guide MR0012J
Preface

A Reader’s Comment Form at the back of this publication is for communicating suggestions or requests for change. We encourage and appreciate reader feedback.
The following paragraphs describe how to locate the training available for the 9710 Library.
If you have questions about registering for courses (including tuition and schedules), call the registrar at 303-673-6262.
Consult the current Corporate Education Course Catalog or view EDUCATION announcements on the intranet using Netscape for the latest offerings and schedules.
StorageTek employees should follow these steps to register:
This takes you to the StorageTek Workforce Development web page. Make your selections from here.
MR0012J 9710 System Assurance Guide xv
Preface

This page intentionally left blank.
xvi 9710 System Assurance Guide MR0012J
Preface


Figure 1-1 shows the system assurance overview. The system assurance team members appear across the top of the figure. The process is the exchange of information among the team members to ensure that no aspects of the sale, ordering, and installation are overlooked. This promotes an error-free installation and contributes to customer satisfaction.
Figure 1-1. The System Assurance Overview


Table 1-1 lists the responsibilities of the system assurance team members. The team ensures that all aspects of the process are planned carefully and carried out efficiently. Customer and StorageTek team members jointly own and control the process.
Table 1-1. Team Member Responsibilities
Solutions Delivery Installation Consultant (SDIC) (United States)
Solutions Delivery Manager (SDM) (international)
Marketing representative (United States)
System Assurance Team · Team Member Responsibilities

Table 1-1. Team Member Responsibilities (Continued)
Solutions Delivery Engineer (SDE) • Prepares customer service support procedures.
Customer • Works with the solutions delivery installation consultant (SDIC) at the system assurance planning meetings to provide the data for the worksheets listed for the SDIC.
Solutions Delivery Systems Specialist (SDSS)
System Assurance Team · Team Member Responsibilities

The System Assurance Flowchart
Figure 1-2 shows the system assurance process flow. The following pages describe the steps in more detail.
No two installations are the same; however, following this flowchart promotes a smooth system assurance process and an error-free installation.
Figure 1-2. The System Assurance Process Flow


The System Assurance Flowchart
The system assurance process begins when the customer accepts the proposal. At this time, the solutions delivery installation consultant (in the United States) or the solutions delivery manager (internationally) schedules one or more system assurance planning meetings.
The purpose of the system assurance planning meetings is to:
Depending on the customer, the appointed team member must now either:
See Chapter 4 for which of the above options and fax numbers to use.
If the sales entry form or order worksheets are complete and correct, OM or SSC approves the order and assigns a ship date. If they are not correct, OM or SSC contacts the system assurance team for more information.
The purpose of the system assurance review meetings is to:

If the preinstallation checklists are complete and correct, the sale is approved and the product is shipped. If they are not correct, the system assurance team completes or corrects them.
The SDE installs the 9710 Library at the customer’s site.
The following actions follow up the installation:
When schedule planning is completed, attach a copy of the proposed schedule to this guide, and have the system assurance team members sign below.
Schedule Planning · StorageTek Representative (date) · Customer Representative (date)

This chapter enables you to record the names and phone numbers of the key personnel on the teams. The home phone number is optional.
List names and telephone numbers of the following people:
Phone office: home:
Phone office: home:
Phone office: home:
Phone office: home:
Phone office: home:

List names and telephone numbers of the following people:
Phone office: home:
Phone office: home:
Phone office: home:
SDE room on site:
Phone office: home:

StorageTek Hardware and Software
StorageTek provides the following phone numbers for hardware and software support:
Call Center (Hardware) U.S.-Colorado 1.303.673.4056 U.S.-Outside Colorado (Customers) 1.800.525.0369 U.S.-Outside Colorado (SDEs) 1.800.735.2778 Software Support U.S.-Outside Colorado 1.800.678.4430 U.S.-Colorado 1.303.673.4430
List names and telephone numbers of the following CPU vendor people:
Phone office: home:
Phone office: home:
Phone office: home:
Phone office: home:
Phone office: home:
Phone office: home:

List names and telephone numbers of the following people:
Phone office: home:
Phone office: home:
Phone office: home:
SDE room on site:
Phone office: home:

This chapter provides an overview of the LSM, drive configurations, and interfaces.
The 9710 library consists of:
Figure 3-1. 9710 LSM with Expansion Door

The LSM is shipped standard with no drive plates and with two 14-pack arrays above the drive wall (Panel 2). If fewer than four drives are ordered, two 14- pack arrays are installed above the three drives. If fewer than seven drives are ordered, one 14-pack array is installed above the six drives.
If the LSM is to contain more than six drives, you must also install the optional power distribution unit (PDU) and the PRM logic card.
Follow these rules for the cartridge drives, their associated arrays, and the cartridges used in the drives:
When mixing 4890 and DLT drives within the same LSM:
When installing only DLT drives:
When mixing 9840 and DLT drives within the same LSM:
When installing only 9840 drives:
The standard 9710 can support up to 10 drives, but has power connections for only six drives. When you order the 9710 mounting hardware kits for more than six drives, you must also order the PDU. The PDU gives you power connections for four additional drives.
The PDU is a pass-through AC connector box with a power drop cable at one end and receptacles for four drives at the other end. The box is mounted in the 9710, but must be connected to a separate customer power drop. The international version comes without a cable plug, and cable leads are stripped.
Drive Configurations

The PRM card is shipped with the PDU, even though it is not part of the PDU. The card is mounted in the 9710 to provide data communication paths for the additional drives.
The LSM provides two host ports for AS/400 direct connections. Two internal LSM cables are supplied for this configuration (see Figure 3-2 on page 3-4). Other configurations with the AS/400 might include a RISC/6000 server (see Figure 3-3 on page 3-5). Direct connections in non-AS/400 (open systems) configurations are also supported (see Figure 3-4 on page 3-6).
For host indirect connections to the LSM, a server [Unix-based, using Automated Cartridge Server Library (ACSLS) software or a RISC System/6000, using the Advanced Interactive Executive (AIX) operating system] is connected between the host and the LSM. An example of an indirect connection is an LSM hooked to a Unix server, with the server connected to an Ethernet LAN network. A cable is run from the Ethernet LAN to the host (see Figure 3-5 on page 3-7).
The connection from the server to the LSM is a SCSI Type-3 68-pin cable. The server may have its own control-side path (through a connection on the optional PRS circuit card), or may be daisy-chained to a shared data bus with one or more drives.
Figure 3-6 on page 3-8 shows the generic software requirements for the subsystems in either a direct connection or an indirect connection to the LSM.
Host Interfaces

Figure 3-2. Direct Connection for AS/400 Control

Host Interfaces

Figure 3-3. Client Configuration (Indirect Connection) with AS/400

Host Interfaces

Figure 3-4. SCSI Direct Connection (Open Systems) with Common Bus

Host Interfaces

Figure 3-5. Host-Indirect Connection

Host Interfaces

Figure 3-6. Subsystem Generic Software Types

Host Interfaces

Refer to the 9840 Tape Drive System Assurance Guide, MT 5003, for 9840 data interface information.
The LSM has three data interfaces available:
You may order FIPS bus drives, SCSI bus drives, or both. FIPS and SCSI are not available on the same drive.
Two FIPS data bus terminal blocks are present on a drive. Each bus in this definition includes the Data In, Data Out, Tag In, and Tag Out lines. You can use the two terminals for two data buses, use only one terminal block and terminate the other, or use the second terminal block for daisy chaining.
Each SCSI drive has two SCSI data bus connectors. You may use only one SCSI data bus input per drive. The other connector must be terminated, or it can be used for daisy chaining in a non-AS/400 environment, but it cannot be used for a second data bus.
Each DLT has two SCSI data bus connectors. You can use only one SCSI data bus input per drive. The other connector must be terminated, or it can be used for daisy chaining, but it cannot be used for a second data bus.
Examine Figure 3-7 on page 3-11 and Figure 3-8 on page 3-12 while you read the following discussion.
Only one SCSI control line can exist. The other SCSI port, on both the SCSI card and the I/O tower, is reserved for daisy chaining; it should be terminated on the SCSI control interface card.
Two RS423/RS232 control lines can exist on the I/O tower. Each control may be connected to a separate AS/400.
Six FIPS data buses can exist on the I/O tower. Each bus in this definition includes the Data In, Data Out, Tag In, and Tag Out lines. If you are using two- bus FIPS drives, each connected at the I/O tower to two FIPS buses, then no
Data Interfaces

more than three FIPS drives can exist in the 9710. The remaining available drive slots can be used by SCSI drives.
Twenty SCSI data buses can exist on the I/O tower: 10 in and 10 out.
Twenty Fibre Channel data buses can exist on the I/O tower (with 9840 drives only): 10 in and 10 out.
The 3270 ports on the I/O tower currently are not used.
The 9710 uses RS423 electronics in its control interface, rather than RS232. The RS423 and RS232 protocols are the same, but the RS423 electronics can drive a signal to greater distances.
The maximum RS423 cable length is 60 m (200 ft).
The fast/narrow interface is single-ended or differential, and supports up to eight devices including the host.
The fast/wide interface is differential only, and supports up to 16 devices including the host.
Both interfaces are provided with the fast/wide 68-pin connector.

SCSI Library Robotic Interface
Figure 3-7. 9710 I/O Panel (Showing FIPS)

not presently used. One of the two SCSI control interface ports is used for the control line; the other is reserved for daisy chaining.

SCSI Library Robotic Interface
Figure 3-8. 9710 I/O Panel (Showing Fibre Channel)

not presently used. One of the two SCSI control interface ports is used for the control line; the other is reserved for daisy chaining.

This chapter provides the worksheets to use when ordering the 9710 LSM.
To order a 9710 LSM:
The orders department, the fax number, and the documents to fax depend on the customer. The department addresses and voice phone numbers are for your information.
Domestic customers, value-added distributors (VADs), and value-added resellers (VARs) must:
You are encouraged to use the software tool Galileo to identify a valid configuration, generate an accurate quote, and produce an error-free sales entry form.

5390 Triangle Parkway, Suite 300 Norcross, GA 30092 Voice: 1-678-969-4000 or 1-800-903-7278 (toll-free in the U.S. only)
Original equipment manufacturers (OEMs), distributors, and subsidiaries in Canada, Japan, Australia, South Asia, and Mexico must fax the following forms to Orders Management:
One StorageTek Drive Louisville, CO 80028-4350 Voice: 1-303-673-5513
Use the following paragraphs and worksheets to plan your order.
For 9840 Drive information, refer to 9840 Tape Drive System Assurance Guide, MT 5003.
Hardware Order Worksheets

Figure 4-1. 9710 Model/Feature Selections

include a SCSI card.
Hardware Order Worksheets

Figure 4-2 on page 4-5 lists the DLT8000 model and feature number. Figure 4-3 on page 4-6 and Figure 4-4 on page 4-7 list the DLT7000 and DLT4000 feature numbers. The drives will ship with either a SCSI Fast/Narrow Differential interface or a SCSI Fast/Narrow Single-Ended interface. You will need SCSI Fast/ Wide 68-pin connectors to connect to the differential drives.
Each kit contains one DLT drive, differential terminator, slides, drive mounting tray, drive actuator mechanism, drive chassis, DLT power supply, cooling, hardware to mount the drive to the tray, and the drive power cord.
The PDU feature code includes the PDU, the appropriate power cord, the PRM card, and an additional drive-to-LSM interface cable.
Hardware Order Worksheets

Figure 4-2. DLT8000 Model and Feature Selections
Hardware Order Worksheets

Figure 4-3. DLT7000 Feature Selections

Hardware Order Worksheets

Figure 4-4. DLT4000 Feature Selections

Hardware Order Worksheets

Figure 4-5 lists the 4890 drive feature numbers.
Figure 4-5. 4890 Drive Feature Selections

Hardware Order Worksheets

The PDU power cables are included when you order the PDU feature code. They are listed below in case you still want to order them separately.
Table 4-1. PDU Cables
Description Part Number Quantity K Cable assembly, international, 200–240 V, 10 A, 3 m (10 ft), 2-wire and ground. For main PDU
K Cable assembly, international, 200–240 V, 10 A, 2.4 m (8 ft), harmonized cord 1.5 mm2, EuroPlug. For optional PDU
K Cable assembly, South Korea, 100–127 V, VCTF cord 3 x 1.25 mm2, KSC 8305 plug. For optional PDU
K Cable assembly, domestic, twisted lock, 200–240 V, 20 A, 2.5 m (8.2 ft), 14 AWG SJT cord. For main PDU
K Cable assembly, domestic, twisted lock 200–240 V, 15 A, 2.5 m (8.2 ft), 16 AWG SJT cord. For optional PDU
K Cable assembly, domestic, 100–127 V, 20 A, 3 m (10 ft), 14 AWG SJT cord, NEMA 5-20P (IEC 320 plug). For main PDU
K Cable assembly, domestic, 100–127 V, 15 A, 2 m (7 ft), 16 AWG SJT cord, NEMA 5-15P (IEC 320 plug). For optional PDU
K Cable assembly, domestic, twisted lock, 100–127 V, 20 A, 2.5 m (8.2 ft), 14 AWG SJT cord. For main PDU
K Cable assembly, domestic, twisted lock, 100–127 V, 15 A, 2.5 m (8.2 ft), 16 AWG SJT cord. For optional PDU
If the robot is controlled by a serial RS423 connection, the 9710-end of the cables requires a female DB9 connector.

Serial Cables, 9710 to Host
Table 4-2. Serial Cables, 9710 to Host
Description Part Number Quantity K Cable assembly, DB9 (F)-DB24 (F), 4 m (13 ft) 310227101
K Cable assembly, DB9 (F)-DB24 (F), 12 m (39.4 ft) 310227301 ________
K Cable assembly, DB9 (F)-DB24 (F), 24 m (79 ft) 310227401 ________

The following pages contain SCSI cable and adapter information.
Maximum allowed cable lengths (including the lengths already inside the 9710) are:
(tailgate). Customers using SCSI Type 1 or 2 cable connectors must order a SCSI-1- or 2-to-SCSI 3 adapter for the LSM-end of their cables to correctly mate with the LSM.
Table 4-3 lists additional restrictions for SCSI connections.
Table 4-3. SCSI Cable Restriction
SCSI Cabling · Application Length Restriction

Figure 4-6. SCSI Connector Types

SCSI Cabling

When considering the length of an external SCSI interface bus, you must subtract the length of bus already inside the 9710 from the maximum allowed cable length. The individual cable measurements inside the 9710 are:
- 0.5 m (18 in.), or - 1.2 m (4 ft), or - 1.8 m (6 ft)
The total length of cable that must be subtracted from each bus is shown in Table 4-4. For the IBM AS/400 system, always subtract 1.2 m (4 ft) from the control or data bus. The AS/400 does not allow daisy chains.
Table 4-4. SCSI Cable Length Subtraction
Number of drives on the same data bus
Are data and control on the same bus? (Yes/No)
Subtract this value from maximum allowed cable length
1 (always 1 for AS/400) no (always no for AS/400) 1.2 m (4.0 ft) from drive bus 2.4 m (8.0 ft) from control bus
2 no 1.7 m (5.5 ft) from drive bus 2.4 m (8.0 ft) from control bus
3 no 2.1 m (7.0 ft) from drive bus 2.4 m (8.0 ft) from control bus
4 no 2.6 m (8.5 ft) from drive bus 2.4 m (8.0 ft) from control bus
5 no 3 m (10.0 ft) from drive bus 2.4 m (8.0 ft) from control bus
6 no 3.5 m (11.5 ft) from drive bus 2.4 m (8.0 ft) from control bus
7 no 4 m (13.0 ft) from drive bus 2.4 m (8.0 ft) from control bus
8 no 4.4 m (14.5 ft) from drive bus 2.4 m (8.0 ft) from control bus
9 no 5 m (16.0 ft) from drive bus 2.4 m (8.0 ft) from control bus
SCSI Cabling

Table 4-4. SCSI Cable Length Subtraction (Continued)
Number of drives on the same data bus
Are data and control on the same bus? (Yes/No)
Subtract this value from maximum allowed cable length
10 no 5.3 m (17.5 ft) from drive bus 2.4 m (8.0 ft) from control bus
1 yes 2.4 m (8.0 ft) from bus 1
2 yes 3 m (9.5 ft) from bus 1
3 yes 3.4 m (11.0 ft) from bus 1
4 yes 3.8 m (12.5 ft) from bus 1
5 yes 4.3 m (14.0 ft) from bus 1
6 yes 4.7 m (15.5 ft) from bus 1
7 yes 5.2 m (17.0 ft) from bus 1
8 yes 5.6 m (18.5 ft) from bus 1
9 yes 6 m (20.0 ft) from bus 1
10 yes 6.6 m (21.5 ft) from bus 1
SCSI Cabling

There are many external SCSI cables, depending on the platform. These cables are available through StorageTek. These are “standard” and will fit most applications for data and the control path.
Table 4-5. SCSI Cables 9710 to Host
x Description Part Number Quantity K Type CL21 SCSI External Interface Cable 3 m (10 ft) 10083309
K Type CL2P2 SCSI External Interface Cable 3 m (10 ft) 10083313
K Type CL2 SCSI External Interface Cable 6 m (20 ft) 10083310
K Type CL2P SCSI External Interface Cable 6 m (20 ft) 10083314
K Type CL2 SCSI External Interface Cable 15 m (49 ft) 10083311
K Type CL2P SCSI External Interface Cable 15 m (49 ft) 10083315
K Type CL2 SCSI External Interface Cable 20 m (65 ft) 10083312
K Type CL2P SCSI External Interface Cable 20 m (65 ft) 10083316
K SCSI Daisy Chain Cable 460 mm (18 in.) 310292001 _____
SCSI Cabling

Table 4-6. Specialized Daisy Chain Cables
x Description Part Number Quantity
K SCSI cable assembly, 2,130 mm (84 in.) 1–6 control 313115701 ________
K SCSI cable assembly, 460 mm (18 in.) 310292001 ________
K SCSI cable assembly, 1,220 mm (48 in.) 7–10 control
K SCSI cable assembly, 250 mm (10 in.) 9840 313109302 ________
K SCSI cable assembly, 460 mm (18 in.) 9840 310292001 ________
Table 4-7 lists available terminators if your configuration requires additional terminators.
Table 4-7. Daisy Chain Terminators
x Description Part Number Quantity K Terminator, fast/wide SCSI, 68-pin, single ended 10148002
SCSI Cabling · 310292101

When installing a PRS in the 9710, the cables listed below are required from the PRC to the drives.
Table 4-8. PRS Card Cables
Drive Location Cable Length Part Number Quantity
9 1220 mm (48 in.) 310292101
8 1220 mm (48 in.) 310292101
7 1220 mm (48 in.) 310292101
6 1830 mm (72 in.) 310254001
5 1830 mm (72 in.) 310254001
4 1830 mm (72 in.) 310254001
3 1830 mm (72 in.) 310254001
2 1830 mm (72 in.) 310254001
1 2130 mm (84 in.) 313115701
0 2130 mm (84 in.) 313115701
SCSI Cabling

The SCSI control card can be connected directly to the I/O panel or can be daisy chained to a tape drive.
Table 4-9. Robotics Control Cables, Internal
x Description Part Number Quantity K SCSI cable assembly, 68 (M) pin to 68 pin (F), 2,440 mm (96 in.) PRS to I/O panel 310294201
K SCSI cable assembly, 68 (M) pin to 68 pin (M), 40 mm (18 in.) PRS to drive (daisy chain) 310292001
K SCSI cable assembly, 68 (M) pin to 68 pin (M), 1,220 mm (48 in.) PRS to drive (daisy chain) 310292101
K SCSI cable assembly, 68 (M) pin to 68 pin (M), 1,820 mm (72 in.) PRS to drive (daisy chain) 310254001
SCSI Cabling

The AS/400 special SCSI cables come in two models: above floor, and under floor (plenum). They must be used with the AS/400, and any other system which has similarly designed SCSI connectors.
only the IBM AS/400 Interposer connector, Part Number 05H3834. This IBM adapter connects standard 68–68 pin SCSI cables to the AS/400. In that case, do not order any additional cables.
Table 4-10. SCSI Cables and Adapters for AS/400 Path
x Description Part Number Quantity K IBM 68–68-pin AS/400 interposer connector is an adapter connector to attach standard 68–68-pin SCSI cables to the AS/400. Order this connector if you already have standard SCSI cables on site. If you do not, order only the cables below.
05H3834 (order from IBM)
K AS/400 special 68–68-pin SCSI cable, 3 m (10 ft) goes above floor
K AS/400 special 68–68-pin SCSI cable, 3m (10 ft) goes under floor (plenum)
K AS/400 special 68–68-pin SCSI cable, 6 m (20 ft) goes above floor
K AS/400 special 68–68-pin SCSI cable, 6 m (20 ft) goes under floor (plenum)
K AS/400 special 68–68-pin SCSI cable, 24 m (78.7 ft) goes above floor
K AS/400 special 68–68-pin SCSI cable, 24 m (78 ft) goes under floor (plenum)

Table 4-11. SCSI Cables and Adapters for Sun Sparc Workstation
x Description Part Number Quantity K StorageTek 3 m (10 ft) cable to attach the 9710 directly to the Sun/Sparc workstation motherboard, or to a station with SBE/S (fast/narrow, differential) or RSBE/S (fast/narrow, single-ended)
K Standard 68–68-pin SCSI cable. With this workstation interface feature, standard SCSI cables can be used without adapters: DWIS/S (fast/wide, differential)
SCSI Cabling · 10083522

Table 4-12. SCSI Cables and Adapters for RS/6000 and Bull DPX/20
x Description Part Number Quantity K StorageTek 3 m (10 ft) cable to attach the 9710 directly to the Sun/Sparc workstation motherboard, or to a station with IBM RISC System/6000 with interface feature code 2420 (fast/narrow, single- ended)
K StorageTek 3 m (10 ft) cable to attach the 9710 directly to the Sun/Sparc workstation motherboard, or to a station with BULL DPX/20 with fast/narrow, single-ended feature
K IBM 68–68-pin (RISC System/6000) Interposer connector. This is an IBM adapter connector to attach standard 68–68-pin SCSI cables to RISC System/6000 with interface feature code 2416 (fast/ wide, differential). Use with one of the standard 68–68-pin cables.
50G0460 (order from IBM)
K IBM 68–68-pin (RISC System/6000) Interposer connector. This is an IBM adapter connector to attach standard 68–68 pin SCSI cables to BULL DPX/20 with fast/wide differential feature. Use with one of the standard 68–68-pin cables.
50G0460 (order from IBM)
K 68–68-pin special SCSI cable RISC System/6000 with IBM245 differential fast/wide adapter 12 m (40 ft). Use this cable in place of the IBM (50G0460) interposer and standard cables above, if a 12 m (40 ft) cable length is satisfactory.

Table 4-13. Adapters, SCSI
x Description Part Number Quantity K SCSI adapter, narrow to wide bus (50-to-68 pin) 10148010
Table 4-14. Single-Ended Narrow or Fast/Narrow to Wide SCSI
x Description Part Number Quantity K Cable assembly, 50 (M) D Squeeze Lock, 68 (M) D Screw Lock, 3 m
Table 4-15. High Density 68-68 Pin Jackscrew SCSI
x Cable Length Metric (English)
Above Floor Cable P/ N
Plenum (under floor Cable P/N) Quantity
K 6 m (20 ft) 10083310 10083314 ______
K 15 m (49 ft) 10083311 10083315 ______
K 20 m (66 ft) 10083312 10083316 ______
SCSI Cabling · 10083522

Table 4-16. AS/400 Serial Cables
x Description Part Number Quantity K Cable assembly, serial AS/400, 4 m (13 ft) 310227101
K Cable assembly, serial AS/400, 12 m (39 ft) 310227301 ________
K Cable assembly, serial AS/400, 24 m (79 ft) 310227401 ________
Cables specific to Sequent are listed below.
Table 4-17. Sequent Cables
x Description Part Number Quantity K SCSI DIFF, TM 68-pin, 5 m (16.4 ft) 308398701
K SCSI DIFF, TM 68-pin, 0.3 m (1 ft) 308398901 ________
K SCSI DIFF, TM 68-pin, 1.2 m (4 ft) 308399001 ________
K SCSI DIFF, TM 68-pin, 7.5 m (25 ft) 308399101 ________
K SCSI DIFF, TM 68-pin, 15 m (49 ft) 308399201 ________
K SCSI, DIFF, Terminator, 68-pin, 308399301 ________
SCSI Cabling

The following pages contain FIPS cable and adapter information.
The two types of FIPS cables are Bus and Tag, and Internal Style. The Bus and Tag cables come in pairs. The Internal Style cable is a single cable with a shorter length limit.
A Y (serpentine) adapter cable may have to be used, depending on the AS/400 IOP and FIPS cable types. Cabling configurations are shown in Figure 4-7. Part numbers are listed below. The flagged 4-digit IBM part numbers must be ordered from IBM.
Figure 4-7. FIPS AS/400 Cabling Configurations

FIPS Cabling

Table 4-18. FIPS Cables
Description Part Number Quantity K Serpentine cable adapter, AS/400 IOP side (see usage in Figure 4-7 on page 4-24).
9980 (order from IBM)
K Y cable adapter, tape side (see usage in Figure 4-7 on page 4-24)
9927 (order from IBM)
K Internal Style cable 1.7 m (5.6 ft) 9928 (order from IBM)
K Internal Style cable 6.6 m (22 ft) 9929 (order from IBM)
K Internal Style cable 24 m (79 ft) 9930 (order from IBM)
K Bus and tag cable pair 15.24 m (50 ft) 305436050 ________
K Bus and tag cable pair 23 m (75 ft) 305436075 ________
K Bus and tag cable pair 31 m (100 ft) 305436100 ________
K Bus and tag cable pair 61 m (20 ft) 305436200 ________
K Bus and tag cable pair 91.44 m (300 ft) 305436300 ________
K Bus and tag cable pair 122 m (400 ft) 305436400 ________
FIPS Cabling

The following table lists available terminators if your configuration requires additional terminators.
Table 4-19. FIPS Terminators
K Terminator, FIPS, Tag 10041794 ________
The FIPS cable is listed below.
Table 4-20. FIPS Cables
x Description Part Number Quantity K FIPS cable assembly from drive to I/O panel 310259302
FIPS Cabling

If the client plans on using a modem for remote support, make sure that one of the following modem cables is ordered.
Table 4-21. Modem Cables
K 15 m (50 ft) 4108289-05 ________
K 31 m (100 ft) 4108289-10 ________
K 46 m (150 ft) 4108289-15 ________
K 61 m (200 ft) 4108289-20 ________
K 76 m (250 ft) 4108289-25 ________
Table 4-22. Remote Diagnostic Support for PC Use
x Description Part Number Quantity K Cable assembly, RJ45 8 pin (M) - RJ45 8 pin (M), 6 m (20 ft) 410828902
K Cable assembly, RJ45 8 pin (M) - RJ45 8 pin (M), 15 m (50 ft) 410828905
K Cable assembly, RJ45 8 pin (M) - RJ45 8 pin (M), 76 m (250 ft) 410828925
Modem Cables

Cartridge Tapes and Labels
The Media Service Center in Atlanta handles orders for cartridge tapes and labels. To obtain additional information about cartridge tapes and labels call the Media Service Center at 1-800-905-8502, or fax 1-877-888-0609; from 8:00 a.m. to 8:00 p.m. United States Eastern Standard Time Monday through Friday.
must be in place. We recommend that you order the necessary cartridges ahead of time.
For 9840 drives, order PN 310319401 (data cartridges used for diagnostics) and PN 310324601 (cleaning cartridges).
Order cartridge tapes and labels by including the order on the sales entry form, if used; the media portion of the order will be routed to the appropriate department.
Orders for domestic customers, valued-added distributors (VADs), and value-added resellers VARs):
5390 Triangle Parkway, Suite 300 Norcross, GA 30092 Voice: 1-800-905-8502 Media Service Center Fax: 1-877-888-0609
Orders from distributors, original equipment manufacturers (OEMs), and Canada, Japan, Australia, South Asia, or Mexico subsidiaries:
Orders Management Fax: 1-303-673-2640 for distributors or subsidiaries Fax: 1-303-673-7654 for OEM One StorageTek Drive Louisville, CO 80028-4350 Voice: 1-303-673-5513
Table 4-23. In-Country Media Supply Services (Sheet 1 of 2)
Region Country Telephone Number
Canada 1-800-668-1843 extension 605
Mexico 525 258 8000
United States 1-800-905-8502 · North America

Cartridge Tapes and Labels
Table 4-23. In-Country Media Supply Services (Sheet 2 of 2)
Region Country Telephone Number
Austria 0800 20 16 31
Belgium 0800 75 327
France 0800 82 83 57
Germany 0800 181 6238
Holland 0800 022 8496
Ireland 1800 55 33 54
Italy 167 790 852
Norway 800 11 220
South Africa 0800 99 5820
Spain 900 99 33 66
Switzerland 0800 83 87 65
United Kingdom 0800 731 8852
Brazil 55 11 5185 2850
Japan 3 3746 9824
Singapore 65 774 9248
Kuala Lumpur 60 3 233 6102
China 86 10 6841 2211
Thailand 662 656 8873
Hong Kong 852 8200 0791

Cartridge Tapes and Labels
This page intentionally left blank.

On the following pages, verify that all issues have been addressed and resolved. Circle either “Yes” or “No” for each item. For unresolved issues, assign a required action with a due date to the appropriate person.
Table 5-1. Pre-installation Checklist
Item Description Yes/No Action Required/Due Date/Person Responsible
Options or features ordered
Tapes and labels ordered
Software prerequisites met Yes/No

Table 5-1. Pre-installation Checklist (Continued)
Item Description Yes/No Action Required/Due Date/Person Responsible
K Yes K No
Ensure customer is aware that StorageTek does not supply fire suppression systems. Any fire suppression system for the 9710 is the customers’ responsibility.
K Yes K No
StorageTek offers an exclusive remote service to customers which is available 24 hours a day 7 days a week if a problem with the equipment occurs.
Table 5-2 lists the remote support hardware and cables to provide remote support for the customer.
Table 5-2. Remote Support Hardware and Cables
Equipment Description Part Number Ref Number
Modem 9600 Baud 4953 1
16 Port MARS+ 32 Port MARS+ 4954 4955 5 5

Table 5-2. Remote Support Hardware and Cables (Continued)
Equipment Description Part Number Ref Number
Cable RJ-45 to RJ-45
20 ft MARS/UUT interconnect 50 ft MARS/UUT interconnect 100 ft MARS/UUT interconnect 150 ft MARS/UUT interconnect 200 ft MARS/UUT interconnect 250 ft MARS/UUT interconnect
410828902 410828905 410828910 410828915 410828920 410828925
7
Modem/ MARS Interconnect Cable
4 ft modem to MARS interconnect (DB-25 to DB-9)
Hardware Support Services

This page intentionally left blank.
Hardware Support Services

This appendix provides specifications and floor space requirements.
The following table lists the dimensions and weight of the LSM. Refer to your drive publications for the weight of the drives and cartridges and add the weights to the weights in the table.
Table A-1. 9710 Dimensions and Weights
Height 1830 mm (72 in.)
Width with covers 1490 mm (59 in.)
Depth 790 mm (32 in.)
Depth with expansion door 1020 mm (40 in.)
Weight of base unit with arrays 339 kg (747 lbs)
Weight of base unit with expansion door and arrays
375 kg (826 lbs)
Table A-2. LSM Power Specifications
120 or 240 VAC
Power consumption 200 W
MR0012J 9710 System Assurance Guide A-1

Table A-3. Optional Power Distribution Unit (PDU) Specifications
120 or 240 VAC
Power consumption 38 W
Table A-4. LSM Environmental Specifications
Temperature Operating Storage Shipping
15° to 32°C (59° to 90°F) 10° to 40°C (50° to 104°F) 10° to 40°C (50° to 104°F)
Relative Humidity Operating Storage Shipping
20% to 80% (noncondensing) 10% to 95% (noncondensing) 10% to 95% (noncondensing)
Wet Bulb Maximum Operating Storage Shipping
Altitude Operating Storage Shipping
0 to 3.05 km (0 to 10,000 ft) 0 to 3.05 km (0 to 10,000 ft) 0 to 15.24 km (0 to 50,000 ft)
A-2 9710 System Assurance Guide MR0012J

Figure A-1. 9710 Layout and Floor Space Requirements
POWER CABLE CUTOUT
148.82 (58.59) 153.26 (60.34)
218.92 (86.19)
218.92 (86.19)
15.24 (6)
60.96 (24)
(SEE NOTE 2)
149.12 (58.71) 153.57 (60.46)
240.23 (94.58)
NOTES:
91.44 cm (3.0 ft) access required during installation. Library may then be pushed back against a wall and stablilized.
Cable cutout is optional as cables may be routed above the floor. For raised floor installation, a 15.24 x 61cm (6 X 24 in.) cutout is recommended if FIPS cables are used.
The dimensions in parentheses are in inches.
MR0012J 9710 System Assurance Guide A-3

Table A-5. Power Characteristics
Description Value / Part Identification Picture
Power drops for 9710 and PDU 1, each: (47-63 Hz AC range. 3-wire cables supplied. International cables are supplied without cable connectors)
9710 120 VAC domestic plug feature code 70DD
NEMA 5-20P, supplied with 9710
PDU 120 VAC domestic plug NEMA 5-15P, supplied by client
9710 120 VAC domestic wall receptacle
NEMA 5-20R, supplied by client
PDU 120 VAC domestic wall receptacle
NEMA 5-15R, supplied by client
International plugs and receptacles for 9710 and, if applicable, for PDU
May be supplied by client according to local electrical codes. See power specifications below. See Table 4-1 on page 4-9.
Current input for library without drives 1
1.250 A at 120 VAC 0.625 A at 240 VAC 2.000 A at 120 VAC
Current input for each 4890 drive 1 1.000 A at 240 VAC 0.60 A at 120 VAC 0.30 A at 240 VAC
Power usage for library without drives 1
Watts 150 peak / 100 Continuous KVA 0.15 Peak / 0.10 Continuous
A-4 9710 System Assurance Guide MR0012J

Table A-5. Power Characteristics (Continued)
Description Value / Part Identification Picture
Power usage for library without drives 1
Watts 150 peak / 100 Continuous KVA 0.15 Peak / 0.10 Continuous
Power usage for each 4890 drive 1 Watts 270 Peak / 230 Continuous KVA 0.27 Peak / 0.23 Continuous
Power usage for each DLT drive 1 Watts 70 Peak / 60 Continuous KVA .070 Peak / .060 Continuous
Heat output for library without drives
Heat output for each 4890 drive 880 BTU/hr
Heat output for each DLT drive 257 BTU/hr
MR0012J 9710 System Assurance Guide A-5
680 BTU/hr

This page intentionally left blank.
A-6 9710 System Assurance Guide MR0012J

Please check or fill in the items; adding explanations/comments in the space provided.
Which of the following terms best describes your job?
K Field Engineer K Manager K Programmer K Systems Analyst K Engineer K Mathematician K Sales Representative K Systems Engineer K Instructor K Operator K Student/Trainee K Other (explain below)
How did you use this publication?
K Introductory text K Reference Manual K Student/Trainee K Instructor text K Other (explain)
Did you find the material easy to read and understand? K Yes K No (explain below)
Did you find the material organized for convenient use? K Yes K No (explain below)
Specific criticisms (explain below):
Clarification on pages Additions on pages Deletions on pages Errors on pages
Explanations and other comments:
Thank you for your cooperation. No postage stamp is required if mailed in the U.S.A.


TO COMPLY WITH POSTAL REGULATIONS, FOLD EXACTLY ON DOTTED LINES AND TAPE (DO NOT STAPLE)
NEARLINE INFORMATION DEVELOPMENT MS 2201 STORAGE TECHNOLOGY CORPORATION ONE STORAGETEK DRIVE LOUISVILLE CO 80027-9984
FOLD HERE AND TAPE DO NOT STAPLE FOLD HERE AND TAPE
STORAGE TECHNOLOGY CORPORATION ONE STORAGETEK DRIVE Louisville, CO 80028-2201



World Headquarters Storage Technology Corporation One StorageTek Drive Louisville, Colorado 80028 USA Phone: 1.800.786.7835 Fax: 719.536.4053
© 1999 Storage Technology Corporation, Louisville, CO. All rights reserved. Printed in USA. StorageTek, the signature, and Information Made Powerful are trademarks of Storage Technology Corporation. Other product names mentioned may be trademarks of Storage Technology Corporation or other vendors/manufacturers.