Brunel Mk III Conventional Flue With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR0595 Issue 4 (August 2008) IMPOR T ANT Do not attempt to burn rubbish in this fire. This stove must only be operated with the door secured firmly in position.
2 CONTENTS COVERING THE FOLLOWING MODELS BRUNEL - 8050 - P8050 PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Technical Specifications 8 Site Requirements 9 In.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 2.3 • Holdin for 5to 10seconds and thenrelease The pilot remains lit. If the pilot does not light, repeat the procedure.
5 4.2 • Holdin the controlknob androtate anti-clockwise until the knob is pointing at the ignition symbol ( ★ ) • Applya lightedmatch tothe pilothood, Diagram 3 3 AR0897 4.
6 USER INSTRUCTIONS AR0900 6 6.4 • Placethree coals equallyspaced onthe rear ofthe fuel bed so they touch the rear panel, Diagram 7 AR0901 7 6.
7 USER INSTRUCTIONS 9. 'RUNNING IN' 9.1 The surface coating on your GAZCO stove will ‘burn off’ during the first 24 hours of operation on high, producing a harmless and temporary odour. If the odour persists ask your retail for advice. 10.
8 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models Brunel - 8050 - P8050 Model Gas Cat. Gas Type Pressure Nox Class Aeration Injector Gas Rate m 3 / h Input kW (Gros) Country Hoog Laag Brunel 8050 I 2H Natural Gas (G20) 20mbar 5 4 x 16 120 0.
9 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm (5”) in diameter. The following are suitable for use with this appliance.
10 2.3 Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. • Connectthe gassupply tothe 8mm-compressionelbow at the RH rear corner of the stove, Diagram 3.
11 AR0886 4 2.7 • Placethe closure plateagainst thefireplace opening • • Ensurethere is sufficientoverlap aroundthe perimeter to allow a fume tight seal to be made • Cutstraight acrossthe topof theplate if trimmingis required 2.
12 3.5 • Placefive coals onthe frontof the fuelbed sothey rest on the front coal effect and lean against the vertical fingers, Diagram 9 AR0902 9 3.
13 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING 1.1 • Closeall openable doorsand windowsin the room • Ignitethe stoveand operateon maximum for10 minutes AR0539 1 If there is any doubt, run the stove for a further 10 minutes, and repeat the test.
14 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 and retry. Check alignment of pilot burner head, change the ignition lead, see diagram 1 on page 17.
15 SERVICING INSTRUCTIONS FAULT FINDING CHARTS PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipework or fittings which lead to the fire.
16 3. IGNITION LEAD AND PIEZO Due to the method of manufacture, these components can only be replaced as an integral unit. 3.1 • Turnthe gas supplyoff atthe isolation d.
17 AR0320 3 • Prisethe smallretaining ringout ofthe inlet andremove the filter 4.2 • Replacewith a newfilter andpush into positionensuring that it sits on the shoulder • Replacethe retainingring andpush intoposition.
18 8. PRIMARY AERATION PLATE 8.1 • Turnthe gas supplyoff atthe isolation device. 8.2 To open the doors: • Slackenthe domednut onthe upperdoor and loosen the bolt from behind the latch 8.
19 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Date of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: ................................. Next Service due: ............................... N e x t S e r v i c e d u e : .
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
デバイスStovax 8050の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Stovax 8050をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはStovax 8050の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Stovax 8050の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Stovax 8050で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Stovax 8050を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はStovax 8050の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Stovax 8050に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちStovax 8050デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。