SuperiorメーカーCFPF-CMNの使用説明書/サービス説明書
ページ先へ移動 of 24
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 1 Unvented Decorative Gas Fireplaces P/N 903589 REV. E 02/2004 CFST -CMN CFPF-CMN CFST -CMP CFPF-CMP MODELS ST ANDARD SERIES INST ALLA TION INSTRUCTIONS FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM HEATERS.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 GENERAL INFORMATION The CFST and CFPF Series Unvented Room Heaters covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating. These heaters have a standing pilot and are manually controlled through the use of a milli- volt gas valve.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WAR- RANTY.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 Example: CFST/PF heater 34,000 BTU/Hr Gas appliance #1 32,000 BTU/Hr (water heater) Total = 66,000 BTU/Hr * Do not include direct-vent gas appliances. Direct-vent is sealed combustion and draws combustion air from the outdoors.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 41 ⁵⁄₈ ” (1210 mm) Figure 1 A hearth extension is not required with this appliance.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 6 CFST FRAMING SPECIFICATIONS CFST APPLIANCE SPECIFICATIONS A 22 ³⁄₄ " (578 mm)* B 43" (1092 mm) Min.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 7 Figure 6 Figure 7 Figure 8 C A B Gas Line CFPF FRAMING SPECIFICATIONS CFPF APPLIANCE SPECIFICATIONS Gas Line Energy Wall 2 x 4 Outside Wall Drywall Dr.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 8 Step 2 . Route a ¹⁄₂ " (13 mm) gas line along the left or right side framing ( Figure 9 ). All appliances have a 3" long ³⁄₈ " NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Step 7. Installing the Optional Remote Wall Switch – The standard millivolt system comes from the factory wired as shown in Figure 12 . Select a convenient location for the remote wall switch and connect the wiring to the appliance ( Figure 13 ).
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 10 Assembling the Logs WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VERMICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. Figure 15 Step 9. The heater includes a set of ceramic fiber logs.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 11 The installation of the logs and twigs, should be complete and resemble Figures 15, 16 and 19 . After setting the logs and rockwool into posi- tion as described above, ensure the logs are properly and firmly situated.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 12 The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 13 Gas Flex Line with Valve A gas flex line kit is available to aid in attaching the appliance to the gas supply.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 14 ACCESSORIES AND COMPONENTS Forced Air Kit FAB-1100 Remote Control Kit RCK Rocker Switch Kit RS Wall Switch Kit WSK Gas Flex Line Kit GFLV Decorative .
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 15 OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS 1. Stop! Read the safety information above. 2. Make sure manual shut-off valve is fully open. 3. Locate gas control knob and piezo.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 16 Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 17 CFST REPLACEMENT PARTS LIST CFST GAS CONTROLS — MILLIVOLT CFST-CMN CFST-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123071 1 123072 1 2. Bar, Louver (Black) 104951 8 104951 8 3.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 18 REPLACEMENT PARTS – CFST 8 20 9 21 22 23 a. b. c. d. f. g. e. 3 2 1 7 6 2 11 4 5 10.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 19 CFPF REPLACEMENT PARTS LIST CFPF GAS CONTROLS — MILLIVOLT CFPF-CMN CFPF-CMP No. Description Part No. Qty. Part No. Qty. 1. Gas Fireplace Assembly 123073 1 123074 1 2. Bar, Louver (Black) - Main Panel 104951 8 104951 8 3.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 20 REPLACEMENT PARTS – CFPF 11 20 12 21 22 23 13 4 2 1 10 14 7 6 2 5 3 3 9 a. b. c. d. e. 8 f. g..
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 21 1. When igniter button is pressed, there is no spark at ODS/pilot. 2. Heater produces unwanted odors. 3. Heater shuts off in use (ODS operates). 4. Gas odor even when control knob is in “OFF” position.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 22.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 23.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 24 Printed in U.S.A. © 1997 by SFC P/N 903589 REV. E 02/2004 Catalytic Gas Fireplace Manufacturer's Limited W arranty 10 Y ears THE WARRANTY The manufacturer warrants the components of this Catalytic Gas Fireplace manufactured by SFC, INC.
デバイスSuperior CFPF-CMNの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Superior CFPF-CMNをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはSuperior CFPF-CMNの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Superior CFPF-CMNの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Superior CFPF-CMNで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Superior CFPF-CMNを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はSuperior CFPF-CMNの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Superior CFPF-CMNに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちSuperior CFPF-CMNデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。