NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 42" Wood Burning Fireplaces P/N 700,026M REV. C 11/2003 BR-42 BC-42 BRI-42 BCI-42 BR-42-2 BC-42-2 MODELS WH Report No. J99025865B-231 ST ANDARD SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc. PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Note: Install the hearth extension only as illus- trated. The safety strips should extend from front of the fireplace at least 1 ¹⁄₂ " and should extend to be at least flush with the sides.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 10 Figure 8 Figure 9 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details. Frame appliance enclosure as illus- trated in Figures 11 through 14 on page 8.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 11 Figure 12 Figure 13 Figure 15 Figure 16 Figure 14 Framing Dimensions A 46 ¹⁄₄ " 1175 mm B 43 ¹⁄₂ &quo.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 4. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Note: If there is a room above ceiling level, firestop spacer must be installed on the bottom side of the ceiling. If an attic is above ceiling level, firestop spacer must be installed on top side of ceiling joist (Figures 21 and 22 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Next, slide roof flashing over extended chimney section that previously has been installed above the roof opening in Step 4. FTF8 flashings require flashing spacers. Slide flashing all the way down until the flashing base rests flat on the roof ( Figure 30 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Figure 34 4. Pull up slightly on CTD to ensure locking joint has firmly engaged. Using a FTF8-CTDT Chase Termination: Refer to specific installation instructions in- cluded with the FTF8-CTDT chase termination for clearance and installation details.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 FTF8 VERTICAL ELEVATION CHART Height Of Number Of FTF8 Chimney Only Chimney Lengths Inches Feet/Inches 12" 18" 36" 48" Height Of.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 A B FTF8-ES30 Number of FTF8 Chimney Sections Offset Height Offset/Return FTF8-S4 (Inches) (Inches) Elbow Stabilizer 12" 18" 38" 48&q.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Figure 43 HOUSE WIRING COVER PLA TE Replace Cover Plate After Electrical Hook-Up POWER TO THE FIREPLACE The Optional Blower Kit Operates on 115 volt.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Figure 44 THIS FIREPLACE IS NOT INTENDED TO BE USED AS A SUBSTITUTE FOR A FURNACE TO HEAT AN ENTIRE HOME. USE FOR SUPPLE- MENTARY HEATING ONLY. The FBK-100/200 Blower Kits are design certi- fied by Warnock Hersey for use with these appliances.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 It is especially important to insulate between the studs of an outside chase cavity and under the floor if the floor is above ground level. Do not place insulation directly against the fire- place or chimney system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 48 Figure 49 Methods of Determining Hearth Extension and Wall Shield Equivalents To determine the thickness required for any material when ei.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Secure the hearth extension to the floor to prevent possible shifting. FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 INSTALLATION COMPONENTS Outside Combustion Air Kits (with duct) 81L87 FOAK (without duct) 81L88 FOAK-LD Combination Offset/Return Elbow 63L28 FTF8-O.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Printed in U.S.A. © 2001 by LENNOX P/N 700,026M REV. C 11/2003 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.
デバイスTOA Electronics BR-42の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TOA Electronics BR-42をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTOA Electronics BR-42の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TOA Electronics BR-42の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TOA Electronics BR-42で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TOA Electronics BR-42を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTOA Electronics BR-42の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TOA Electronics BR-42に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTOA Electronics BR-42デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。