NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 36" Wood Burning Fireplaces P/N 700,024M REV. N/C 05/2004 CR-3835R CR-3835L MODELS CUSTOM SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 2 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Note: Install the hearth extension only as illus- trated. The safety strips should extend from front of the fireplace at least 1 ¹⁄₂ " and should extend to be at least flush with the sides.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 11 17 1/2" (445mm) 32 7/8" (835mm) 21" (533m) 6" (152mm) 40 1/2" (1029mm) 37 3/8" (949m.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Framing Dimensions CR-3835 Series A 42 ¹₂ " (1080 mm) B 40 ⁵₈ " (1032 mm) C 24 ¹₂ " (622 mm).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 8. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 CHIMNEY 30 ° OFFSET THROUGH FLOOR OR CEILING It may be necessary to assemble the chimney at 30 ° when passing through the floor or ceiling area. Use the F8FS30-2 firestop spacer as shown in Figures 22 and 23 .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Note: If chimney extends more than 8' above roof surface, guy wires are also recommended. Use three (3) guy wires, attach to locking band assembly, extend and secure to roof in a trian- gular pattern (Figure 31 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 Figure 33 Figure 34 This suggestion is provided in the interest of better operation. If the terminations are located too close to each other, smoke may migrate from one flue into the other. CTD 18" 18" 24" 24" CTDT CTDT Less Than 10' 3' Min 2' Min.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 The offset and return elbows may be attached together, or a section or sections of chimney may be used between, but do not exceed 20' in total length between elbows. If sections of pipe exceed 10' between elbows, a chimney stabi- lizer must be used at the midpoint ( Figure 35 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 FTF8 VERTICAL ELEVATION CHART 10 ¹⁄₄ 01 0 ¹⁄₄ 1 0 0 0 0 – 0.26 16 ¹⁄₄ 14 ¹⁄₄ 0 1 0 0 0 – 0.41 22 ¹⁄₄ 11 0 ¹⁄₄ 0 0 1 0 0 – 0.57 26 ¹⁄₂ 22 ¹⁄₂ 1 1 0 0 0 – 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 FTF10 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 FTF8 OFFSET ELEVATION CHART (With FTF8-SS Starter Section) A B FTF10/8-ES30 FTF8-SS Number of FTF8 A B Offset Height Offset/Return Starter FTF8-S4 C.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 37 Figure 38 Figure 39 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past 6' No Screws Required In Joints .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 41 Operate the actuator through several cycles including the "lock position. Ensuring proper operation and freedom of movement.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 These fireplaces may sit directly on a com- bustible surface. A 2" air space is required between combustible framing and the chim- ney. A 1" air space is required between com- bustible framing and fireplace outer wrapper.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 Methods of Determining Hearth Extension and Wall Shield Equivalents To determine the thickness required for any material when either the k or r valu.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Take Off Boot 91L04 FATO FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 21 63L42 FTF8-CTD Round Termination 63L43 FTF10-CTD Chase Termination 63L48 FTF8-CT1 (Square) 63L49 FTF10-CT1 Chase Termination 63L45 FTF8-CTDT (Round).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 22.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 23.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 24 Printed in U.S.A. © 2004 by LENNOX HEARTH PRODUCTS P/N 700,024M REV. N/C 05/2004 1110 West Taft Avenue Orange, CA 92865 The manufacturer reserves t.
デバイスTOA Electronics CR-3835Lの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
TOA Electronics CR-3835Lをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはTOA Electronics CR-3835Lの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。TOA Electronics CR-3835Lの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。TOA Electronics CR-3835Lで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
TOA Electronics CR-3835Lを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はTOA Electronics CR-3835Lの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、TOA Electronics CR-3835Lに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちTOA Electronics CR-3835Lデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。