VanguardメーカーGas Log Heaterの使用説明書/サービス説明書
ページ先へ移動 of 36
Save this manual for future reference. UNVENTED (VENT -FREE) NA TURAL GAS LOG HEA TER WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
2 103515 CONTENTS SECTION PAGE SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS IMPORTANT: Read this owner ’ s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.
3 103515 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
4 103515 PRODUCT IDENTIFICA TION Figure 1 - Product Identification Control Knob Back Log Base Assembly Piezo Ignitor Burner Crossover Log Front Log Flame-Max Standard Oak Logs Flame-Max Golden.
5 103515 LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223, also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
6 103515 PROVIDING ADEQUATE VENTILATION The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1.
7 103515 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space.
8 103515 W ARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.
9 103515 W ARNING Never install the heater • in a bedroom or bathroom unless installed as a vented appli- ance (see page 14) • in a recreational vehicle • where curtains, furniture, clothing, or.
10 103515 INSTALLATION AND CLEARANCES (Vent-Free Operation Only) W ARNING Maintain the minimum clearances. If you can, provide greater clear- ances from floor, ceiling, and adjoining wall. INST ALLING Continued Carefully follow the instructions below.
11 103515 INST ALLING Continued Continued NOTICE Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace opening is not needed.
12 103515 INST ALLING Continued Minimum Non Combustible Material Clearances If Using Mantel You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick.
13 103515 INST ALLING Continued Floor Clearances A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).
14 103515 INST ALLING Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note: When used as a vented heater, appliance must be installed only in a solid- fuel burning fireplace with a working flue and constructed of non combustible material.
15 103515 INST ALLING Continued INSTALLING HEATER BASE ASSEMBLY WARNING ICON G 001 W ARNING You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak. WARNING ICON G 001 W ARNING If installing in a sunken fireplace, special care is needed.
16 103515 INST ALLING Continued Heater Gas Regulator Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator Figure 12 - Attaching Base Assembly t.
17 103515 INST ALLING Continued CONNECTING TO GAS SUPPLY NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. Installation Items Needed Before installing heater, make sure you have the items listed below.
18 103515 Tee Joint Pipe Nipple Cap 3" Minimum Sediment Trap Gas Regulator From Gas Meter (5" W.C.** to 10.5" W.C. Pressure) A.G.A. Design-Certified Manual Shutoff Valve With 1/8" NPT Tap* Approved Flexible Gas Hose (if allowed by local codes) WARNING ICON G 001 CAUTION Avoid damage to regulator.
19 103515 Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter. 3. Check all joints from gas meter to manual shutoff valve (see Figure 15).
20 103515 INST ALLING Continued WARNING ICON G 001 W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. For Vintage Oak Log Model Each log is marked with a number.
21 103515 INST ALLING Continued For Golden Oak or Birch Models It is very important to install the logs e xactly as instructed. Do not modify logs. Only use logs supplied with heater . 1. Place one-piece log set on grate to f it as illustrated in Figure 19.
22 103515 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
23 103515 WARNING ICON G 001 W ARNING Do not operate heater between PILOT and HIGH positions. WARNING ICON G 001 CAUTION Do not try to adjust heating levels by using the manual shutoff valve.
24 103515 OPERA TING HEA TER Continued T O TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Press in and turn control knob clockwise Clockwise to the HIGH position. 2. Turn the control knob clockwise Clockwise to the PILOT position. 3. Press in control knob and turn clockwise Clockwise to the OFF Position.
25 103515 CLEANING AND MAINTENANCE WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passage- ways of heater clean. Inspect these areas of heater before each use.
26 103515 TROUBLE- SHOOTING Continued REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Turn control knob to PILOT position 3. Press in control knob while in PILOT position 4. Continue holding down control knob. Repeat igniting operation until air is removed 5.
27 103515 OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial opera- tion Heater produces a whistling noise when burner is lit Moisture/condensation noticed on windows REMEDY 1.
28 103515 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). TROUBLE- SHOOTING Continued W ARNING If you smell gas • Shut off gas supply.
29 103515 When gas pressure is too low • pilot will not stay lit • burners will have delayed ignition • heater will not produce specified heat When gas quality is bad • pilot will not stay lit • burners will produce flames and soot • heater will backfire when lit You may feel your gas pressure is too low or gas quality is bad.
30 103515 ILLUSTRA TED P ARTS BREAKDOWN Flame-Max Vintage Oak Log Models VYS18N and VYS24N 4 1 2 3 12 21 10 11 21 7 21 5 6 8 9 15 14 16 19 22 18 13 19 17 20-2 20-1 20 18 23.
31 103515 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.
32 103515 ILLUSTRA TED P ARTS BREAKDOWN Flame-Max Golden O a k and Birch Log Models VYD24N and VYBD24N 4 20 10 11 12 20 7 20 20 5 6 9 8 15 14 16 18 2 17 13 18 3 19-2 19-1 19 17 1A 1B.
33 103515 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual. KEY PART NUMBER FOR NO. VYD18N VYBD18N VYD24N VYBD24N VYD30N VYBD30N DESCRIPTION QTY.
34 103515 ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the address listed on the back page of this manual.
35 103515 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for three (3) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
デバイスVanguard Gas Log Heaterの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vanguard Gas Log Heaterをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVanguard Gas Log Heaterの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vanguard Gas Log Heaterの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vanguard Gas Log Heaterで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vanguard Gas Log Heaterを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVanguard Gas Log Heaterの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vanguard Gas Log Heaterに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVanguard Gas Log Heaterデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。