Vermont CastingメーカーDVRT36の使用説明書/サービス説明書
ページ先へ移動 of 50
Homeowner's Installation & Operating Manual INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER Direct V ent Models: DVRT36 DVRT39 DVRT43 INST ALLER/CONSUMER SAFETY INFORMA TION PLEAS.
2 Vermont Castings, Majestic Products DVRT 3 6/ 39/ 43 10002428 Installation & Operating Instructions General Information ............................................................................................................ .............. 3 Locating Your Fireplace .
3 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 Vermont Castings, Majestic Products DVRT 3 6/ 39/ 43 10002428 Fireplace Dimensions (Installed as T op V ent) CFM188 Fig. 2 Fireplace specifications and framing dimensions.
5 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 C L Q - Rough Opening Width 7" Dia. 4" Dia. Rough Opening Height Electrical Access Rough Opening Depth Recessed Nailing Flange .
6 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Mantels The height a combustible mantel is fitted above the fireplace is dependent on the depth of the mantel. This also applies to the distance between the mantel leg (if fitted) and the fireplace.
7 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws or nails. Holes for securing the unit to floor are located behind the access door grille on the left and right sides of the unit.
8 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 The gas pipeline can be brought in through the side of the fireplace as well as the bottom. Knockouts are provided on the bottom behind the valve to allow for the gas pipe installation and testing of any gas connection.
9 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes; or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations, follow the local codes and the national electrical code ANSI/NFPA No.
10 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 After conversion to top vent configuration, the 4” (102mm) flue pipe should be concentric within the 7” (175mm) outer collar. Installing the DVRT36RMH in a Mobile Home NOTE: Refer to “For Use in Mobile Homes: Model DVRT36RMH” on Pages 46 and 47.
11 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 General V enting Y our fireplace is approved to be vented either through the side wall, or vertically through the roof. NOTE: Only venting components specifically approved and labeled for this fireplace may be used.
12 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Fixed Closed .
13 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 General Information for Connecting V ent Pipes Crimped End Pipes Before joining elbows and pipes, apply a bead of high temperature sealant to the crimped end of the elbow or pipe. Join the pipes using a 2” (51mm) overlap and secure the joints with three (3) sheet metal screws.
14 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Twist-lock Pipes When using Vermont Castings, Majestic Products twist-lock pipe it is not necessary to use sealant on the joints.
15 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Rear W all V ent Installation Step 1 Locate and cut the vent opening in the wall. For combustible walls, first frame in opening. (Fig. 20) Combustible Walls: Cut a 10 ³⁄₈ ”H x 9 ³⁄₈ ”W (265 x 240mm) hole through the exterior wall and frame as shown.
16 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 It is very important the venting system maintain its balance between the combustion air intake and the flue gas exhaust, therefore, certain limitations as to vent configurations apply and must be strictly adhered to.
17 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 In Fig. 25a and Fig. 25b, Dim. A plus Dim. B must not be greater than 17’ (5.2m). • The maximum number of 45 ° elbows permitted per side wall installation is two (2). These elbows can be installed in either the vertical or horizontal run.
18 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Below Grade Installation Step 2 Measure wall thickness and cut zero clearance sleeve parts to proper length (maximum 12” / 305mm). As- semble sleeve and attach to firestop with #8 sheet metal screws (supplied).
19 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Do not backfill around snorkel. A clearance of at least 4” (102mm) must be maintained between the snorkel and the soil. If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel.
20 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 • Up to two (2) 45 ° elbows may be used within the horizontal run. For each 45 ° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18” (450mm). Example: Maximum horizontal length No elbows = 10’ (3m) 1 x 45 ° elbows = 8.
21 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Gravity Ducting System Do not discharge directly into a wall or inside an enclosure. 3. Materials needed for the gravity ducting installation: • (2) 5” dia. duct to grille connector boots • (2) Wall Outlet grilles • 5” dia.
22 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 CFM180 Fig. 40 Gravity vent locations. Sheet Metal Screws Gr avity Duct Plug.
23 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 T wist Lock V enting Components 7TDVRVT - Through-the-Wall Rear Vent Termination Starter Kit - Model 7TDVSK - Sidewall Venting Starter K.
24 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 7DVRVT - Through-the-Wall Rear Vent Termination Starter Kit - Model 7DVSK - Sidewall Venting Starter Kit - Model 7TDVSKV - Vertical Vent.
25 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Operating Instructions Only glass approved by Vermont Castings, Majestic Products should be used on this fireplace. • The use of any nonapproved replacement glass will void all product warranties.
26 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Installation of Logs & Lava Rock DVRT39 - Refer to Figure 44. 1. Remove the top louvre assembly. 2. Remove the window frame assembly. 3. Fit the rear log (B35) onto the rear log support.
27 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 RN/ RP Models For units equipped with ‘HI/ LO’ valves the flame adjustment is accomplished by rotating the “HI/ LO” adjustments knob located near the center of the gas control valve.
28 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 NOTE: Glowing lava rock for DVRT36, DVRT39 and DVRT43 is only allowed to be positioned at the front area (radiant portion) of the burner housing assembly.
29 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.
30 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Lighting & Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
31 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Instructions for RF Comfort Control Valve The Comfort Control Valve allows remote control of temperature, fan and flame appearance. 1. If the manual switch is in remote position, switch it to LOCAL .
32 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 In the AUTO mode, the room temperature, set temperature, flame and fan levels will be shown. AUTO will appear next to both flame and fan icons. When the control is in the AUTO mode, the main burner will turn On/ Off or modulate based on the heat needed to maintain the set temperature.
33 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Auto Path Chart If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter .
34 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Comfort V alve System Control Sequence of Operation with T ransmitter If manual switch is set to LOCAL , did main burner light and fan turn on? T urn pilotstat knob to PILOT to turn off main burner .
35 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 T roubleshooting – Honeywell VS8421 Remove the Window Frame Assembly before service work. START CHECK Gas Supply On ▼ ▼ ▼ ▼ ▼ Pilot Lights With Piezo Ignitor • Lockout Has Engaged.
36 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 T roubleshooting the Gas Control System Note: Before trouble shooting the gas control system, be sure external gas shut off is in the “ON” position. SIT NOV A 820 MILLIVOL T V AL VE SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1.
37 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 SIT 822 Valve with a Honeywell Electronic Igniter Troubleshooting the Gas Control System ST ART •TURN GAS SUPPL Y OFF • TURN ON/OFF .
38 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Fuel Conversion Instructions The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variation is in the orifice sizes and component part numbers.
39 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Regulator Cap Conversion Screw Pressure Regulator Housing Honeywell Gas V alve Cleaning the Standing Pilot Control System The burner and.
40 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 1b 1c 1d 1f 1g 1h 1i L O H I PILOT ADJ P I L O T ON OFF 6a/b 9a/b 10 a/b 24 25a/b 26a/b 27 33 34 37 38 39 23 12 21 13 20 22 1b 1c 1d 1e .
41 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 DVRT36/39/43 (continued) (Items marked ‘*’ are not shown in the parts illustration.) Ref. Description DVRT36 DVRT39 DVRT43 1. Log Set (Complete) 10002427 10002469 10002853 1a. Log - Rear N/A B35 N/A 1b.
42 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 DVRT36/39/43 (continued) Ref. Description DVRT36 DVRT39 DVRT43 27. FK24 Fan Assembly w/Bracket (Optional) 54103 54103 54103 28. FK12 Fan Assembly (not shown) ZA1 1 10 ZA1 1 10 ZA1 1 10 29.
43 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Optional Accessories Fan Kits Hard (Direct) Wire Hookup FK-12 Fan Assembly 1. Open lower louvre. 2. Install FK-12 fan in back of unit between hearth supports. (Fig. 57) 3. Secure fan on Velcro strips.
44 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 Remote Controls Optional remote control units are available to control different functions of the appliance.
45 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 Decorative Frame Trim A selection of decorative frame trim kits is available for mounting around the outside of the appliance to enhance its visual affect on the room. Installation instructions for each decorative frame trim are included with the frame trim kit.
46 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accor.
47 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 8. Remove the compression fitting which holds the aluminium tubing in the pilot assembly. This will reveal the pilot orifice which must be replaced with the one provided in the conversion kit.
48 Vermont Castings, Majestic Products DVRT 36/ 39/ 43 10002428 BASIC WARRANTY Vermont Castings , Majestic Products (hereinafter referred to collectively as the Company) warrants that your new Vermont.
49 10002428 Vermont Castings, Majestic Products DVRT 36/ 39/ 43.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com Ve r mont Castings, Majestic Products Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) DVRT36RN 59.
デバイスVermont Casting DVRT36の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting DVRT36をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting DVRT36の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting DVRT36の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting DVRT36で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting DVRT36を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting DVRT36の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting DVRT36に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting DVRT36デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。