Vermont CastingメーカーEWF30の使用説明書/サービス説明書
ページ先へ移動 of 32
EWF30 Fireplace Homeowner ’ s Installation and Operating Manual Do Not Discard This Manual: Retain for Future Use 20008662 7/06 Rev . 6 SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN- T AINED, A HOUSE FIRE MA Y RESUL T .
2 V er mont Castings EWF30 20008662 Introduction Thank you for purchasing a V ermont Castings, EWF30 fireplace. An efficient fireplace carefully engineered to bring you the latest in wood combustion principles and modern foundry technology .
3 V er mont Castings EWF30 20008662 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
4 V er mont Castings EWF30 20008662 Specifications Range of heat output* ............... 1 1,100 - 40,500 Btu/hr Maximum heat output** ....... in excess of 55,000 Btu/hr EP A emissions rating (g/h) ...................................... 3.5* Area heated*** .
5 V er mont Castings EWF30 20008662 FP1561 EWF30 parts id 3/05 Fig. 2 Fireplace and chase parts identification. FP1561 Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
6 V er mont Castings EWF30 20008662 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet.
7 V er mont Castings EWF30 20008662 Planning Information Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 4) Never install a chimney below minimum heights. In planning a chimney system, it is important to know: 1.
8 V er mont Castings EWF30 20008662 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m). Locate chimney supports at ceiling holes or other structural framing at 30’ (9m) heights.
9 V er mont Castings EWF30 20008662 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materi- als. Refer to framing dimensions in Figure 1 for basic fireplace specifications.
10 V er mont Castings EWF30 20008662 Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used. Mea- sure your offset dimension from straight up chimney center point on ceiling.
1 1 V er mont Castings EWF30 20008662 Installing Outside Air Kit An outside air kit may be installed on the EWF30. The AK-MST allows for 100% of required combustion air to come from outside source. If desired, or if local codes mandate the use of an air kit, then an AK-MST is required to complete the installation (from air kit to the outdoors).
12 V er mont Castings EWF30 20008662 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together .
13 V er mont Castings EWF30 20008662 Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety . Nail the firestop spacer (at each corner) to the framing members of the ceiling hole.
14 V er mont Castings EWF30 20008662 Penetrating the Roof Run pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved CFM Corporation termination. If a chase is used, refer to the installation manual pro- vided with the termination cap.
15 V er mont Castings EWF30 20008662 local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf. All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible material.
16 V er mont Castings EWF30 20008662 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 25 of the fireplace opening must be protected with CFM Corporation W all Shield Model SP40 or a specifically built wall shield described in Figure 20.
17 V er mont Castings EWF30 20008662 FP1201 Fig. 26 Combustible side wall protection and hearth extension dimensions. Minimum W all Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustibl.
18 V er mont Castings EWF30 20008662 Operation Attach Handles The fallaway handle is used to open and close the front doors. Remove after each use so the handle will not get hot.
19 V er mont Castings EWF30 20008662 KT108b BFC Correct door position 8/23/00 djt KT108b Fig. 230 Correct door position during operation. Correct Optional Spark Screen Correct The Fan Heated air from the fireplace is forced into the room by an internal fan.
20 V er mont Castings EWF30 20008662 Starting and Maintaining a Wood Fire Burn solid wood fuel only in the EWF30, and burn it directly on the grate. Do not elevate the fuel. Do not burn coal or other fuels. Minimize thermal stress by allowing the plates to adjust gradually during an initial break-in fire by following Steps 1-3 below .
21 V er mont Castings EWF30 20008662 A well-insulated home, located in a moderate climate and with the EWF30 Fireplace located centrally in an open floor plan, will be easier to heat than a drafty home in the far north in which the EWF30 is installed on an exterior wall at the end of a long house.
22 V er mont Castings EWF30 20008662 Keep your EWF30 Fireplace Looking New and Working Its Best Care of the Cast Iron Surface An occa sio nal dus ting wit h a dry ra g wi ll k eep you r EWF30 fir epla ce look ing new . If the paint needs retouching, first allow the surface to cool completely .
23 V er mont Castings EWF30 20008662 1. Remove the existing fiberglass gasket by grasping an end and pulling firmly . 2. Use a wire brush or the tip of a screwdriver to clean the channel of any remaining cement or bits of gas- ket. 3. Apply a thin bead of fireplace cement to the newly- cleaned groove.
24 V er mont Castings EWF30 20008662 The prefabricated chimney used with your fireplace should be cleaned from above using an 8” round brush and the appropriate number of extension rods for com- plete access. The chimney cap first must be removed following the procedure recommended by the manufacturer .
25 V er mont Castings EWF30 20008662 U.S. Round T op T ermination T op used to terminate chimney at roof. (Flashing not included.) RL TSK8 Round T op T ermination - T op used to terminate chimney at chase.
26 V er mont Castings EWF30 20008662 EWF30 Fireplace CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
27 V er mont Castings EWF30 20008662 Ref. Description EWF30 EWF30 Fireplace (continued) 16. Grate, Flat/Wood 30002087 17. Firebrick, Split 1601 103 18. Bracket, Actuator 20008827 19. Brick Retainer 20008904 20. Brick Retainer 20008725 21. Door Gasket 1/2” Dia.
28 V er mont Castings EWF30 20008662 Optional Accessories Fan Kit FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture.
29 V er mont Castings EWF30 20008662 T rim Kits A choice of two decorative stell face plates with brick ledge for masonry applications (if needed) are available to enhance the look of your EWF30 fireplace. Installa- tion instructions are included with the kit.
30 V er mont Castings EWF30 20008662.
31 V er mont Castings EWF30 20008662 L I M I T E D L I F E T I M E W arranty For V ermont Castings EWF30, Sequoia II, Non-Catalytic W oodburning Fireplace Limited Lifetime W arranty CFM Corporation wa.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスVermont Casting EWF30の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting EWF30をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting EWF30の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting EWF30の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting EWF30で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting EWF30を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting EWF30の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting EWF30に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting EWF30デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。