Vermont CastingメーカーNVC43の使用説明書/サービス説明書
ページ先へ移動 of 28
Decorative Gas Appliance Installation and Homeowners Operating Instructions PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
2 NVC Series B- V e nt 20000194 T able of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 NVC Series B- V e nt 20000194 Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Natural Gas and Propane In- stallation Code.
4 NVC Series B- V e nt 20000194 A D N M N A B S G H J Gas Line Access - 2" Dia. Gas Line Access 2" Dia. Finished W all Thickness 6" Flue Rough Opening Height Rough Opening Width Rough Opening Depth C Electrical Cable Knock-out - 1" Dia.
5 NVC Series B- V e nt 20000194 Clearance to Combustibles Appliances T op .......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ............................
6 NVC Series B- V e nt 20000194 Gas Specifications 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit.
7 NVC Series B- V e nt 20000194 Gas Line Installation When purging gas line the fornt glass must be removed. Purging gas lines must com- ply with ANSI Z223.1/NFP A 54 in USA and CSA B149.1 in Canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom.
8 NVC Series B- V e nt 20000194 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ANSI/NFP A No.
9 NVC Series B- V e nt 20000194 Fig. 9 Firestop/draftstop positions. Ceiling Installation FP384 FIRESTOP 11/21/96 adapted from IGF53 Attic Installation Firestop position when area abov e ceiling is an attic. Firestop position when area abov e ceiling is NOT an attic.
10 NVC Series B- V e nt 20000194 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
1 1 NVC Series B- V e nt 20000194 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (Fig. 12) 7. Place ember material. See "Ember Material Place- ment" section.
12 NVC Series B- V e nt 20000194 T est Chimney Draw A "Chimney Draw" test must be made before the instal- lation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes.
13 NVC Series B- V e nt 20000194 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace.
14 NVC Series B- V e nt 20000194 V ent Safety Switch This fireplace incorporates the use of a V ent Safety Shut-off Switch. The sensor and wiring are factory installed and should not be removed or altered during installation.
15 NVC Series B- V e nt 20000194 T roubleshooting FP649 Turn gas supply off Turn ON/OFF Switch to call for heat. NO NO NO NO NO NO NO Spark across Ignitor Sensor gap Power to module (24V nominal) YES .
16 NVC Series B- V e nt 20000194 Remove glass door before service work Honeywell VS8421 ST ART CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap T o Pilot Hood Needed.
17 NVC Series B- V e nt 20000194 T roubleshooting FP396 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. For Spark at Electrode While Depressing Piezo (Red Button) - 1/8" Gap to Pilot Hood Needed.
18 NVC Series B- V e nt 20000194 Cleaning the Standing Pilot Control System The burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an oc- casional checkup and cleaning and some may require adjustment.
19 NVC Series B- V e nt 20000194 FP772A Replacement Parts nvc 8/25/98 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e NVC43 Logs 1 27 37 2 3 1a 1b NVC36 1d 1e 1c 1e 1c 1a 1b 1d NVC39 1 18 25 17a/b 22 .
20 NVC Series B- V e nt 20000194 NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 6a. Orifice Front Burner-Nat. See Rating Plate 6b. Orifice Front Burner-LP See Rating Plate 7a. Pilot Assy- SIT T op Convertible, LP 10002265 10002265 10002265 7b.
21 NVC Series B- V e nt 20000194 Optional Accessories Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup- ports.
22 NVC Series B- V e nt 20000194 Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and T.
23 NVC Series B- V e nt 20000194 FP1 195 Arched door front 2/27/02 djt FP1 196 Fig. 28 Arched door front in place. EB-1 Electrical Box Standard on electronically controlled models, the EB-1 is also available for other fireplaces. Installation should be completed by a qualified service person.
24 NVC Series B- V e nt 20000194.
25 NVC Series B- V e nt 20000194.
26 NVC Series B- V e nt 20000194.
27 NVC Series B- V e nt 20000194 BASIC W ARRANTY CFM Corporat ion (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN 29.4 NVC36RP 29.4 NVC36RFN 29.4 NVC36RFP 29.4 NVC36EN 28.5 NVC36EP 28.
デバイスVermont Casting NVC43の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting NVC43をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting NVC43の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting NVC43の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting NVC43で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting NVC43を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting NVC43の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting NVC43に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting NVC43デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。