10000801 6/03 Rev. 4 • Installation and service must be performed by a qualified installer, service agency or your gas supplier. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert T able of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLICANCE. Thank you and congratulations on your purchase of a Majestic fireplace. IMPORTANT - Read all instructions and warnings carefully before starting installation.
3 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert R - Fireplace opening width Q - Fireplace opening height S - Depth of insert T - Firebox width at insert depth(S) U - Firebox de.
5 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes appli- cable to woodburning fireplaces.
6 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.
7 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Installation of Trim Switch for RN/RP Gas Valves 1. Thread wire through openings on the right side of fireplace. Do not cut wire or insulation on metal edges. 2. Slide switch assembly from the back, between subframe and trim, then fasten the screw.
8 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 4. The chimney must be clean and in good working order and constructed of noncombustible materials. 5. Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney.
9 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Under no circumstances should insulation be put between the damper and the top of the unit. This may cause condensation and overheating of the unit. Flue Collar Plate 10/24" x 1 ¹⁄₂ " Machine Screw Cabinet Top Fastener Plate FP1281 Fig.
10 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert V enting Components A B C High Temperature Sealant D 8" x 12" Vent Termination Kit Model: HEDVT (8" x 12") .
11 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Operating Instructions General Glass Information Only ceramic glass approved by Vermont Castings, Majestic Products may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties.
12 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert SR2 SR5 SR6 SR4 SR3 SR1 Front Lava Rock Placement LG281 Fig. 20 RHEDV42 log and lava rock placement. Large Lava Rock Placement The large lava rock provided with this fireplace must be placed on the firebox base on either side of the burner assembly.
13 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 3/8" - 1/2" SIT Pilot PSE Pilot F584-703 Fig. 24 Correct pilot flame appearance. RHEDV25/32 Fig. 25 Correct burner flame appearance for RHEDV25 and RHEDV32 models. LG283 RHEDV42 LG283 Fig.
14 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to " OFF ". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
15 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert W ARNING: Before doing any gas control service work, remove glass front. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
16 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Eurosit 630 Gas Valve NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. WARNING: Before doing any gas control service work, remove glass front.
17 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds And Try Again. For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed.
18 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
19 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 35 30 31 32 27 29 36 28 25 26 3 2 33 34 24a/b 15 L O H I PILOT ADJ P I L O T ON OFF 23 a/b 21 20 19 14 12 16 9 a/b 13 18 17 11 .
20 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert RHEDV25/32/42 Series (continued) Ref. Description RHEDV25 RHEDV32 RHEDV42 1. Log Set Complete 10000199 57896 10000206 1a. Log Ember Front JR1 KR1 SR1 1b. Log Front Left JR2 KR2 SR2 1c.
21 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert RHEDV25/32/42 Series (continued) 28. Speed Control 51738 51738 51738 29. Speed Control Knob 51882 51882 51882 30. Glass with Gasket 10000803 5459/7 54234 31. Gasket Glass 57316 57316 57316 32.
22 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Optional Accessories Remote Controls Optional remote control units are available to control different functions of the appliance.
23 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 4 2 3 4 1 6 6 5 FP1289 V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
24 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 1 2 3 4 5 FP1293 V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
25 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert KT210a Fig. 34 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets. KT211a Fig. 35 Engage the slots in the upper grille top louvre with the upper tabs of the hanging brackets.
26 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert A4 Riser Kits For use with RHEDV25 (Refer to Page 34, Figure 55) 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions.
27 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Trim Top Channel Trim Side Channel Trim Framing Inner Sides Screw Trim Side Channel Deflector Trim Top FP1262 Fig. 41 RHESSD and RHESLD trim assembly. A flat louvre kit OR a bay window kit need to be chosen to complete the installation.
28 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 5 1 2 3 6 6 4 7 8 9 1 V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
29 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B2 RHEBSL & RHEBXL Trims For use with RHEDV32 Trim Assembly RHEBSL 1. Install trim channels (left and right sides). Use two screws to assemble each piece. 2. Slide on the trim top channel and fasten it from the back side.
30 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B3 RHEFA and RHEFP Trims For use with RHEDV32 Trim Assembly 1. Remove the front glass (see "Glass Frame Re- moval" section). 2. Install support window trim channel, top and bottom brass trim by using the shortest black screw.
31 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B4 HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA Trims For use with RHEDV32 HECBTK Cast bay window and grilles in classic black.
32 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert On units fitted with a Honeywell brand control valve the location of the control knobs and the ignitor button may vary slightly from those shown in Figure 49.
33 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 1 3 2 3 9 8 4 10 6 5 7 13 6 5 7 20 18 19 12 11 14 15 16 HI LO HECBTK, HECBTKMB, HESBTKP, HEBTKP, HEBTA Trim Parts Replacement 0.
34 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert B5 Cast Trim Options Cast Surround and Flat Face HECBL Cast Surround Black HECBLUE Cast Surround Blue HECCG Cast Surround Charc.
35 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert 1. Install trim channels (left and right sides) by remov- ing the two screws that hold the side brass trim and put them back to hold both parts. 2. Slide on the trim top channel and fasten it from the back side.
36 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Bottom Decorative Plate FP1292 Fig. 59 Slide bottom decorative plate under unit floor. IMPORTANT: Only trim panel assemblies approved by Vermont Castings, Majestic Products can be used on these products.
37 10000801 Vermont Castings, Majestic Products RHEDV Direct Vent Insert Extension Knobs KT204a Fig. 62 Install the knob extensions. (Only for RN/RP models) Fig. 64 Hang the window grille or the steel frame onto the lower tabs of the hanging brackets.
BASIC WARRANTY The Vermont Castings , Majestic Products Company (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
デバイスVermont Casting RHEDV25の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting RHEDV25をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting RHEDV25の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting RHEDV25の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting RHEDV25で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting RHEDV25を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting RHEDV25の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting RHEDV25に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting RHEDV25デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。