Vermont CastingメーカーSA18SHKRPの使用説明書/サービス説明書
ページ先へ移動 of 20
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Corporation Decorative G as A ppliance F or I nstallation I n S olid F uel B urning F ireplaces 331 1857 12/05 Rev .
2 331 1857 W ARNING Do not use this appliance or any part that has been under water . Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water .
3 331 1857 Before Y ou Begin -- Attention! A. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc.
4 331 1857 CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Is the gas supply inlet pressure correct? NG: Min. 5.5” w .c./Max. 14.0” w .c. LP: Min.
5 331 1857 This Damper Stop is designed to work on all CFM Corporation BR, BC, SR, SC, TF and TL series fireplaces. For all other fireplaces, refer to Page 6. When installing a decorative gas appliance in a fireplace, some local codes require this Damper Stop to be used so the Damper will not close com- pletely .
6 331 1857 The Damper Clamp provided keeps your damper from accidentally closing during operation of your set. This Damper Clamp must be installed onto your Damper at all times. NOTE: The damper clamp is designed to hold the damper plate open 3 inches.
7 331 1857 Adding Pan Material 1. Open the bag of V ermiculite and spread it evenly across the Burner Pan, to the top, as shown in Figure 5. Y ou may overflow the front and sides of the pan to cover the entire pan and connecting hardware.
8 331 1857 Leak T est Procedures Create a mixture of equal parts soap and water . Apply to all the joints of the pipe fittings from the gas sup- ply pipe to the burner . T urn on the gas supply valve for no longer than 3-5 seconds. If bubbles appear in the soap solution applied to the joints, there is a leak.
9 331 1857 Optional Fettel Cast Front Grate Attach the fettel to the front of the grate as shown in Figure 9. Log Placement 1. Place the larger bottom logs onto the grate, leaving as much space between them as pos- sible. When burning, the flames should come up directly between the logs.
10 331 1857 LG333 18" Standard split log set 4/04 djt 18” Standard Split Log Set LG333 LG334 24" Standard split log set 4/04 djt 24” Standard Split Log Set LG334 LG335 30" Sta.
1 1 331 1857 The pilot will resist lighting on new installa- tions due to air in the gas supply line. It may take several minutes to bleed air completely out of the gas plumbing system through the pilot line. This appliance has a pilot which is lit by a spark ignition device (piezo).
12 331 1857 T roubleshooting Log Set Is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets (especially propane) to produce moderate levels of carbon (soot) where flame contacts the logs. The logs can be cleaned using a soft-bristle brush.
13 331 1857 T roubleshooting Pilot Will Not Light Upon initial installation, the pilot may be difficult to light, due to air in the gas line, valve, and pilot tubing. If the pilot does not light for several minutes, try using a match to ignite it for the first few times.
14 331 1857 857 ASHKRN/P parts 4/04 djt 1 2 3 4 5 4 6 7a,b 8 10 9 1 1 13 14 12 18a,b 20 21 19 15 17 16a,b 22 24 23 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
15 331 1857 SA18/24/30SHK Series V ented Gas Logs - Remote Hearth Kit (Continued) Ref. Description 18” 24” 30” 13. Gas Supply Fitting 3304145 3304145 3304145 14. Flexible Gas Connector 3304176 3304176 3304176 15. Pilot Bracket 4303232 4303232 4303232 16a.
16 331 1857 5a 5b 5c 5d 5e 5f 956 Log parts 4/04 1a 1b 1c 1d 1e 1f 1 2a 2b 2c 2d 2e 2f 2g (2) 2 3a 3b 3c 3e 3f 3g 3d 3h 3 4a 4b 4c 4d 4e 4f 4 5 6a 6b 6c 6d 6e (2) 6f (2) 6 7a 7b 7c 7d 7e 7 8a 8b 8c 8d.
17 331 1857 5c. 24” Split right Front 20007828 5d. 24” Split Left Front 20007830 5e. T op Log #3 (2 per set) 20008337 5f. T op Log (2 per set) 20008336 6. 30” Standard Split Log Set 20007859 6a. 18”/24”/30” Back Log 20007820 6b. 18”/24”/30” Cross Log 20007699 6c.
.
THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EFFECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FOR TH IN P ARAGRAPHS A AND B. A. Gas Appliances, electrical and manual compo - nents, glass panels, all sea.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Corporation.
デバイスVermont Casting SA18SHKRPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Casting SA18SHKRPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Casting SA18SHKRPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Casting SA18SHKRPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Casting SA18SHKRPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Casting SA18SHKRPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Casting SA18SHKRPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Casting SA18SHKRPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Casting SA18SHKRPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。