Vermont CastingsメーカーVL18の使用説明書/サービス説明書
ページ先へ移動 of 20
Installation and Operation Instructions for V ent-Free Gas Log Sets* Models: VL18, VL21 and VL24 (Natural Gas) VL18LP , VL21LP and VL24LP (Propane) CERTIFIED D E S I G N C E R T I F I E D 20002538 1/07 Rev .
2 20002538 The Logsets have been designed and tested to operate safely when installed according to the installation instructions con- tained in this manual.
3 20002538 Installation Requirements The fireplace must meet the minimum dimensions listed below . (Fig. 1) Do not install the logset if the fireplace does not meet these minimums. Pressure T est Points Copreci V alve: 1/8” N.P .T . plugged tapping is provided on the outlet side of the gas control for a test manifold pressure.
4 20002538 Planning Planning the installation is an important first step. It will save time and money later in the actual installation. In planning the installation, consider: • Where the heater will be located. • All components needed to complete the installation.
5 20002538 Installation Requirements WARNING This heater must have fresh air for proper opera- tion. If it does not, poor fuel combustion could result. Read the following instructions to ensure proper fresh air supply for this and other fuel- burning appliances in your home.
6 20002538 WARNING This heater shall not be installed in a confined space or unusually tight construction unless provisions are made for adequate combustion and ventilation air .
7 20002538 W ARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. W ARNING: Do not use a blower insert, heat ex - changer insert or other accessory not approved for use with this gas logset.
8 20002538 Damper Stop Installation When installing a decorative gas appliance in a fire- place, some local codes require a damper stop be added so the damper will not close completely . The CFM Corporation damper stop is designed so the damper can be locked in the closed position, and still allow a vent for the pilot gasses.
9 20002538 Burner Assembly Location Centrally locate the unit in the fireplace, far enough back into the firebox to accomplish adequate draft (if use as a vented appliance is planned). Ensure the front grate feet sit inside the front edge of the fireplace a minimum of 3 ¹⁄₄ ”.
10 20002538 Check the inlet pressure to the appliance, to ensure that it is as shown in the table on page 3. The minimum is for the purpose of input adjustment. The pressure is controlled by the regulator and should be checked at the pressure test point located in the control valve body .
1 1 20002538 LG100 VL18 logset 3/26/99 changed burner 4/3/00 djt Locator Pins Locator Pin Grate LG100 Locator Pin Fig. 7 VL18 log placement. LG102 VL21 logset 3/31/99 modified burner/grate 4/3/00 djt Locator Pins Grate LG102 Locator Pin Locator Pin Fig.
12 20002538 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace.
13 20002538 When Used as a Heating Appliance 1. This appliance is equipped with a modulating valve which provides variable control of heat output, from approximately 15,000 or 18,000 BTU/hr at the full counterclockwise LOW position, to 24,000, 32,000 or 35,000 BTU/hr at the HIGH position, depending on your appliance.
14 20002538 LF103� VL21 flames � 3/31/99 � changed valve 4/14/00 djt HI OFF PILO T LO LF101� VL18 flames � 3/29/99 � changed valve 4/13/00 djt HI OF F PILO T LO 7” - 9” Approx.
15 20002538 T roubleshooting With proper installation and maintenance, your new Gas Appliance should provide years of trouble-free ser- vice. If you do experience a problem, this guide will assist a CERTIFIED SERVICE PERSON in the diag- nosis of problems and the corrective action to be taken.
16 20002538 1 a b c d HI OFF PILO T LO 2 3 4 5 6a,b 10a,b 7 8 9 1 1a,b 12a,b 13a,b 15a,b 2538 VL18,21,24,30 replacement parts 4/4/00 djt 14 16a,b 17 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
17 20002538 Contact the factory for questions concerning prices and policies covering replacement parts. Parts will be shipped at prevailing prices. Normally , all parts can be ordered through your CFM Corporation distributor or dealer . When ordering replacement parts, always give the fol- lowing information: •The model number of the appliance.
18 20002538 Model No. Accessories The following accessories are available from your CFM Corporation dealer . Should you need additional information beyond what your dealer can furnish, contact CFM Corporation, 410 Admiral Blvd. Mississauga, Ontario, Canada L5T 2N6, Attention: T echnical Service.
19 20002538 MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE), ALL OF WHICH ARE HEREBY EXPRESSL Y INCLUDED. IN NO EVENT SHALL ANY IMPLIED W AR - RANTY PRESCRIBED BY LA W (NOTWITHST ANDING THE FOREGOING EXPRESS EXCLUSION) REMAIN IN EF- FECT AFTER EXPIRA TIONS OF THE W ARRANTIES SET FORTH IN P ARAGRAPHS A AND B.
© CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスVermont Castings VL18の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Vermont Castings VL18をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはVermont Castings VL18の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Vermont Castings VL18の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Vermont Castings VL18で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Vermont Castings VL18を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はVermont Castings VL18の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Vermont Castings VL18に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちVermont Castings VL18デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。