Waterford AppliancesメーカーE61-LPの使用説明書/サービス説明書
ページ先へ移動 of 24
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
2 Waterford E61 Gas Fireplace Insert TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Insert by Waterford Irish Stoves. The Waterford Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch.
3 Waterford E61 Gas Fireplace Insert T ABLE OF CONTENTS W A TERFORD GAS FIREPLACE INSERT Page Page SAFETY LABEL Safety Label .............................................................. 4 INSTALLATION REQUIREMENTS For your safety ...................
4 Waterford E61 Gas Fireplace Insert This is a copy of the label that accompanies each Waterford E61-NG Gas Insert Natural Gas. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel. NOTE: Waterford units are constantly being improved.
5 Waterford E61 Gas Fireplace Insert This is a copy of the label that accompanies each Waterford E61-LP Gas Insert Propane. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel. NOTE: Waterford units are constantly being improved.
6 Waterford E61 Gas Fireplace Insert INST ALLA TION INST ALLA TION INTO AFACTOR Y BUIL T FIREPLACE The WATERFORD Gas Inserts have been test- ed and approved to be vented into any ap- proved Factory Built Fireplace that will allow the Insert to physically fit into the firebox.
7 Waterford E61 Gas Fireplace Insert CLEARANCES TO COMBUSTIBLES The following clearances to combustibles must be observed: From Unit Sides A 9" / 229 mm Unit to Unprotected Mantel B 16" / 40.
8 Waterford E61 Gas Fireplace Insert INST ALLA TION VENTING THE APPLIANCE MUST NOT BE CON- NECTED TO A CHIMNEY FLUE SERV- ING A SEPARATE SOLID FUEL BURN- ING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the full length of the chimney.
9 Waterford E61 Gas Fireplace Insert CONVERSION KIT FROM NA TURAL GAS TO PROP ANE MODEL #260-960 for Emerald E61 Gas Insert using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Qty.
10 Waterford E61 Gas Fireplace Insert INST ALLA TION Pilot assembly is now accessible for steps 6) to 11). 3 ) Remove the door by lifting it slightly up and off the front face. Remove the 7 nuts that secure the front glass bracket holding the center glass in place.
11 Waterford E61 Gas Fireplace Insert Reduction Kit to Lower Btu Rating for Emerald E61 Gas Insert Natural Gas - Kit #: 260-920 Propane - Kit # 260-922 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Natural Gas Conversion Kit 260-920 Contains: Qty.
12 Waterford E61 Gas Fireplace Insert INST ALLA TION SHROUD INST ALLA TION 1) Attach the 2 side Surround Panels to the body. Each side panel attaches to the body with two bolts per side (top and bottom) and use a washer and a 1/2" spacer with each screw.
13 Waterford E61 Gas Fireplace Insert 5) Place the two Small Side Logs beside the burner on the firebox floor, as shown in diagram 4. 6) Distribute the embers along the front burner but do not cover the burner ports and around the logs. Place the embers on the floor of the firebox.
14 Waterford E61 Gas Fireplace Insert INST ALLA TION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.
15 Waterford E61 Gas Fireplace Insert OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
16 Waterford E61 Gas Fireplace Insert OPERA TING INSTRUCTIONS COPY OF THE LIGHTING PLA TE INSTRUCTIONS Gas Control Valve: As the gas control valve turns ON and OFF, a dull clicking sound may be audible, this is normal operation of a gas regulator or valve.
17 Waterford E61 Gas Fireplace Insert FAN MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and cor- rectly sealed.
18 Waterford E61 Gas Fireplace Insert MAINTENANCE Remove the 2 screws holding the Control Panel in place. VAL VE MAINTENANCE If your valve requires maintenance or replace- ment, use the following instructions: Note: Always close off the gas supply before removing the valve.
19 Waterford E61 Gas Fireplace Insert P ARTS LIST REPLACEMENT / SP ARE P ARTS LIST 2 ) 936-243 Gasket - 7/8" w/adhesive 49 ) * Hose Clamp 3-1/16" - 4" 60) 270-013 Front Glass Frame 61 ).
20 Waterford E61 Gas Fireplace Insert P ARTS LIST REPLACEMENT / SP ARE P ARTS LIST 1 ) 942-031** Decorative Door Grill Front 3 ) * Screw - 1/4 x 1/2" Flat Head Phillip Zinc Plate 4 ) 942-021** Fr.
21 Waterford E61 Gas Fireplace Insert P ARTS LIST REPLACEMENT / SP ARE P ARTS LIST 52) 910-190 Piezo Ignitor & Nut 56) 908-672 Control Panel Decal 57) 490-061 Control Panel 270-574/P S.I.T. Valve Assy - NG 270-576/P S.I.T. Valve Assy - LP 58) 910-378 Valve S.
22 Waterford E61 Gas Fireplace Insert NOTES _____________________________________________________________________________________ ______________________________________________________________________.
23 Waterford E61 Gas Fireplace Insert W ARRANTY Waterford Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd.
24 Waterford E61 Gas Fireplace Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________.
デバイスWaterford Appliances E61-LPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Waterford Appliances E61-LPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはWaterford Appliances E61-LPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Waterford Appliances E61-LPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Waterford Appliances E61-LPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Waterford Appliances E61-LPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はWaterford Appliances E61-LPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Waterford Appliances E61-LPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちWaterford Appliances E61-LPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。