What is an inverter?

An inverter is a technical device to invert d. c. voltage into sinusoidal alternating voltage. In the case of the ECTIVE® inverter the d. c. voltage is usually provided by a battery. In this way, the inverter inverts direct into alternating current. The 230 V grounded protect ed contact socket of the inverter allows to operate electronic devices independant of position and autonomously, which usually need a 230 V a domestic power supply.

With the ECTIVE® TSI series, you also have the function of a uninterruptible power supply (UPS). Existing mains current is here prioritized. If the mains is switched off, the inverter automatically switches to battery operation within 16 ms and ensures an uninterrupted operation of your consumers.

ECO-Mode: With the ECO-Mode from TSI50-series you have the additional function of a battery priority circuit. When the ECO-Mode is switched on and AC-Power is available, the battery does not use the AC power and the batteries will not be charged. (ECO-Mode = Energy-Saving-Mode)

The battery priority function is active as long as the battery voltage is over the certain “cut off”-battery voltage (voltage values see the chart “safety features” on page 49). If this value is deceeded and the shore power is still connected, the inverter returns to mains priority circuit to avoid battery damages.

Ective Energy TSI102 — What is an inverter? diagram (page 1)
図 1 · What is an inverter?
Page 2 of the Ective Energy TSI102 user manual — Scope of supply
2ページ · クリックして拡大
2ページ

Explanation of symbols

ѥ ѥ Warning!

Failure to comply with these instructions could result in death or serious injury

⚠ ⚠ Caution!

Failure to comply these instructions can cause functional impairment or damage of the device.

Further information for the operation of the device.

Scope of supply

Ective Energy TSI102 — Scope of supply diagram (page 2)
図 2 · Scope of supply

1 Unit 230 V cold-device plug 1 Unit Operating instructions

300 W 32 12 V 4 mm², 1 set 35 A × 1 ≥50 Ah

34 24 V 2,5 mm², 1 set 20 A × 1 ≥25 Ah

38 48 V 2. 5 mm², 1 set 10 A × 1 ≥12 Ah

500 W 52 12 V 6 mm², 1 set 35 A × 4 ≥100 Ah

54 24 V 4 mm², 1 set 20 A × 4 ≥50 Ah

58 48 V 2. 5 mm², 1 set 10 A × 4 ≥25 Ah

1000 W 102 12 V 10 mm², 1 set 35 A × 4 ≥160 Ah

104 24 V 6 mm², 1 set 20 A × 4 ≥80 Ah

108 48 V 4 mm², 1 set 10 A × 4 ≥40 Ah

Page 3 of the Ective Energy TSI102 user manual — Explanation of symbols
3ページ · クリックして拡大
3ページ

Battery cabel* Fuse/ Unit***

1500 W 152 12 V 10 mm², 2 set 35 A × 6 ≥250 Ah

154 24 V 6 mm², 2 set 20 A × 6 ≥125 Ah

158 48 V 4 mm², 2 set 10 A × 6 ≥60 Ah

2000 W 202 12 V 16 mm², 2 set 35 A × 8 ≥320 Ah

204 24 V 10 mm², 2 set 20 A × 8 ≥160 Ah

208 48 V 6 mm², 2 set 10 A × 8 ≥80 Ah

2500 W 252 12 V 16 mm², 2 set 35 A × 10 ≥400 Ah

254 24 V 10 mm², 2 set 20 A × 10 ≥200 Ah

258 48 V 6 mm², 2 set 10 A × 10 ≥100 Ah

3000 W 302 12 V 16 mm², 2 set 35 A × 12 ≥480 Ah

304 24 V 10 mm², 2 set 20 A × 12 ≥240 Ah

308 48 V 6 mm², 2 set 10 A × 12 ≥120 Ah

4000 W 402 12 V 25 mm², 2 set 35 A × 12 ≥640 Ah

404 24 V 16 mm², 2 set 20 A × 12 ≥320 Ah

408 48 V 10 mm², 2 set 10 A × 12 ≥160 Ah

5000 W 502 12 V 35 mm², 2 set 35 A × 20 ≥800 Ah

504 24 V 25 mm², 2 set 20 A × 20 ≥400 Ah

508 48 V 16 mm², 2 set 10 A × 20 ≥200 Ah

6000 W 602 12 V 35 mm², 2 set 35 A × 20 ≥960 Ah

604 24 V 25 mm², 2 set 20 A × 20 ≥480 Ah

608 48 V 16 mm², 2 set 10 A × 20 ≥240 Ah

* One set contains one positive and one negative wire. ** Recommended capacity of the batteries during permanent power. *** Actual combination of fuses may differ.

Show 5 more labels / short text on this page
Continuous · Model SI-/TSI- · Input voltage · Battery capacity** · output
Page 4 of the Ective Energy TSI102 user manual — Accessory
4ページ · クリックして拡大
4ページ

ѥ ѥ Warning!

If 2 sets of battery cables included the scope of delivery, the two of them have to be installed. Failure to comply the instructions can easily cause an overheating of the over loaded cables and even dangerous cable fires.

⚠ ⚠ Caution!

Please note the capacity!

An underrun of the recommended battery capacity can cause a loss of performance or serious use restrictions as a result of voltage drops.

⚠ ⚠ Caution!

Please respect a sufficient ventilation!

The inverter produces heat loss. The device is equipped with a thermal overload pro tection. An insufficient ventilation can affect the function of the inverter, because the inverter can shut itself down for safety reasons.

Accessory

1 unit Remote K01****

1 unit Remote KS02*****

1 unit 3 m RJ12 remote cable

**** suitable for model from SI50-series ***** suitable for model from TSI50-series

Fire hazard! · Number Designation

Page 5 of the Ective Energy TSI102 user manual — ѥ ѥ Warning!
5ページ · クリックして拡大
5ページ

Intended use

In general the ECTIVE® inverter can be used in all motor vehicles as well as for all sorts of autonomous applications.

⚠ ⚠ Caution!

The inverter should not be used in vehicles, in which the +pole is connected to the chassis.

⚠ ⚠ Caution!

Please mind the input voltage!

The inverter should only be connected to voltage sources which correspond to follow ing provisions. 12 V=12 V, 24 V= 24 V

If connected to a higher voltage source the fuse can immediately blow and destroy the inverter.

ѥ ѥ Warning!

The ECTIVE® inverter of the SI/TSI-series are generally build for so called “Off-Grid”- Systems and should only be used autonomously. Do not connect the inverter output (socket) with an other voltage source. All models with a mains priority circuit should be connected with a power supply only through the provided AC-input. Disregarding this advice is life threatening and will destroy the inverter immediately.

Fire hazard!

Page 6 of the Ective Energy TSI102 user manual — Front view TSI-series: Illustration 1 TSI50 and 100-series
6ページ · クリックして拡大
6ページ

Explanation of the inverter

Illustrations 1-6 show the most important external components and connections.

Front view TSI-series: Illustration 1 TSI50 and 100-series

Ective Energy TSI102 — Front view TSI-series: Illustration 1 TSI50 and 100-series diagram (page 6)
図 3 · Front view TSI-series: Illustration 1 TSI50 and 100-…
1. switch ON/OFF 2. switch for ECO-Mode 3. USB-port
4. LED “Error” 5. shore power connected 6. bypass function “on”
7. shore power connection 8. protective earthing
Page 7 of the Ective Energy TSI102 user manual — Front view TSI-series: Illustration 2 TSI150 to 250-series
7ページ · クリックして拡大
7ページ

Front view TSI-series: Illustration 2 TSI150 to 250-series

Ective Energy TSI102 — Front view TSI-series: Illustration 2 TSI150 to 250-series diagram (page 7)
図 4 · Front view TSI-series: Illustration 2 TSI150 to 250-…
1. switch ON/OFF 2. switch for ECO-Mode 3. USB-port 4. LED “Error”
5. shore power connected 6. bypass function “on” 7. remote control port
8. shore power connection 9. shore power fuse 10. protective earthing
Page 8 of the Ective Energy TSI102 user manual — Front view TSI-series: Illustration 3 TSI300-series
8ページ · クリックして拡大
8ページ

Front view TSI-series: Illustration 3 TSI300-series

Ective Energy TSI102 — Front view TSI-series: Illustration 3 TSI300-series diagram (page 8)
図 5 · Front view TSI-series: Illustration 3 TSI300-series
1. switch ON/OFF 2. switch for ECO-Mode 3. USB-port 4. LED “Error”
5. shore power connected 6. bypass function “on” 7. remote control port
8. shore power connection 9. not used 10. protective earthing
Page 9 of the Ective Energy TSI102 user manual — Front view SI-series: Illustration 5 SI >= 150-series
9ページ · クリックして拡大
9ページ

Front view SI-series: Illustration 4 SI30to 100-series

1. switch ON/OFF 2. LED “Error” 3. USB-port 4. protective earthing

Front view SI-series: Illustration 5 SI >= 150-series

Ective Energy TSI102 — Front view SI-series: Illustration 5 SI >= 150-series diagram (page 9)
図 6 · Front view SI-series: Illustration 5 SI >= 150-serie…
1. switch ON/OFF 2. LED “Error” 3. USB-port 4. remote control port 5. protective earthing
Page 10 of the Ective Energy TSI102 user manual — ⚠ ⚠ Caution!
10ページ · クリックして拡大
10ページ

Front view: Illustration 6 terminal for direct connection (from SI400and TSI300-series)

Ective Energy TSI102 — Front view: Illustration 6 terminal for direct connection (from SI400and TSI300-series) diagram (page 10)
図 7 · Front view: Illustration 6 terminal for direct conne…

L N L N G

Caution!

Please note the maximum power of the electronic devices!

For currents >15 A electronic devices have to be connected directly to the terminal for direct connections.

ѥ ѥ Warning!

Risk of electric shocks

The device is always equipped with security features to prevent dangerous electronic shocks.

To ensure a high level of security when switched on the earth connection of the inverter has to be connected with the protective earthing system (usually green-yellow cable).

Remote control

The remote control is connected by the three meter long RJ12 (ISDN cable) connection cable.

The remote is paralleled to the on/off button of the inverter. For a reasonable use of the remote the inverter has to be switched off.

⚠ ⚠ Caution!

Do not place the remote control cable together with any power cables. This can lead to undesired interference in the function of the remote control.

Possible malfunctions

Page 11 of the Ective Energy TSI102 user manual — K01 REMOTE CONTROL
11ページ · クリックして拡大
11ページ

Front view: Illustration 7 Multi-function remote control K01 (available >= SI50-series)

Ective Energy TSI102 — Front view: Illustration 7 Multi-function remote control K01 (available >= SI50-series) diagram (page 11)
図 8 · Front view: Illustration 7 Multi-function remote con…

K01 REMOTE CONTROL

1. battery status and load display
2. LED “Error” 3. device “on”

Status display:

  • load indicator: flashes 1x/sec. Indicates momentary consumption of the connected electronic devices in 20 % steps.
  • battery status: permanently illuminated. Indicates the remaining capacity of the batteries in 20 % steps.
  • Changes between the battery status and the load indicator every 8 seconds .

Error LED:

  • Flashes red when error occurs. (see table “self error correction”)

Status light:

  • Stand-by display: Flashes when the device is in stand-by mode or if the power consumption is < 5 %.
  • AC on: permanently illuminated when the power is > 5%.
Page 12 of the Ective Energy TSI102 user manual — INVERTER
12ページ · クリックして拡大
12ページ

Front view: Illustration 8 Multi-function remote control KS02 (available >= TSI50-series)

Inverter Remote Controller

FlashFault

BATTERY

LOAD

100 % 100 %

INVERTER

AC IN

BYPASS

OFF

ON

Model No KS-02

1. failure LED 2. battery status 3. inverter on 4. load status 5. bypass on

Bypass-mode: mains priority circuit activated.

Status display:

  • charging status: flashes during the charging process and permanently illuminated when battery is fully charged.

The remote indicates in two tables the instantaneous voltage and percentage utilization in 25% steps proportional to the continuous output of the device.

Show 6 more labels / short text on this page
75 % · 75% · 50 % · 50% · 25% · 25%
Page 13 of the Ective Energy TSI102 user manual — Idle current consumption SI-/TSI-series
13ページ · クリックして拡大
13ページ

Operating conditions

Everything at a glance

Ective Energy TSI102 — Everything at a glance diagram (page 13)
図 9 · Everything at a glance

Power indication proportional to the continuous output indicated in

120 % – 150 % for 10 seconds 150 % – 200 % for 2 seconds

Waveform Pure sine wave (THD < 4%) at rated input voltage

Battery types Wet, AGM, GEL, Li-Ion (only with BMS)

Efficiency

Ective Energy TSI102 — Efficiency diagram (page 13)
図 10 · Efficiency

Idle current consumption SI-/TSI-series

Ective Energy TSI102 — Idle current consumption SI-/TSI-series diagram (page 13)
図 11 · Idle current consumption SI-/TSI-series
Page 14 of the Ective Energy TSI102 user manual — 12 V 24 V 48 V
14ページ · クリックして拡大
14ページ

12 V 24 V 48 V

250 <1,10 A <0,55 A <0,28 A

300 <1,20 A <0,60 A <0,30 A

Surrounding conditions

Operating temperature -15 °C bis 40 °C

Storage temperature -40 °C bis 85 °C

Relative humidity 20 % ~ 90 %

Please mind the starting current!

Keep in mind that inductive devices (for example power drills or refrigerators etc. ) often need a 3–10 times higher power at the beginning than indicated on the descriptive type plate. The maximum power of this short period should not surpass the maximum power of the inverter.

Listen to the acoustic signal!

In case of overload an acoustic signal will sound. If the needed power is not reduced to the maximal continuous output, the inverter will shut down automatically.

Output losses because of heat

An ambient temperature over 40°C (for ex. due to heat at the installation site or direct sunlight) can lower the specified output and efficiency.

Model SI-/TSI-

Page 15 of the Ective Energy TSI102 user manual — ѥ ѥ Warning!
15ページ · クリックして拡大
15ページ

General safety instructions and installation notes

ѥ ѥ Warning!

Limited number of users

The following persons should use this product only under the supervision of another responsible person:

  • persons with limited physical aptitude
  • persons with limited mental aptitude
  • persons with limited sensory aptitude.
  • children under the age of 12
  • Use the device only in accordance with its designated use.
  • Store the device out of the reach of children.
  • Maintenance and repairs may only be performed by a specialist who is familiar with the latest guidelines (for ex. VDEstandards).

ѥ ѥ Warning!

  • The installation of this equipment may only be performed by trained and authorized personnel and in compliance with all safety regulations and guidelines.
  • Especially when used on a boat an incorrect installation can lead to corrosion damage. Therefore the installation should be performed by trained boat electricians.

ѥ ѥ Warning!

To reduce the risk of fire, injuries and electronic shocks, please note the following instructions:

  • Do not cover the ventilation slits and ensure adequate ventilation. The installation site of the inverter has to be well ventilated.
  • Install the inverter only on solid mounting surfaces.
  • Do not pull the cable.
  • Grasp all cables tightly during the mounting and dismantling.

Installation instructions

Page 16 of the Ective Energy TSI102 user manual — General safety instructions and installation notes
16ページ · クリックして拡大
16ページ
  • Always start with connecting the input voltage and switch the inverter on afterwards.
  • Do not install near heat sources or in direct sunlight.
  • Avoid dust, humidity and flammable or caustic substances near the inverter.
  • The inverter heats up during operation, keep away from heat-sensitive materials.
  • Do not drop the inverter and avoid shocks.
  • Do not place any objects on top of the inverter.
  • Only use all of the original cables delivered with the device.
  • Do not open the device.
  • Only use dry wipes for cleaning. Switch off the inverter before cleaning.
  • Switch of the inverter before all kinds of work.
  • In case of sharp-edged ducts please use an empty conduit or cable bushing.
  • Do not use the same duct for the 230 V output cable and the DC cable.
  • Only use the device if the inverter is without any damage.
  • Do not cover the ventilation slits.
  • The power supply must be switched off before handling the device.
Page 17 of the Ective Energy TSI102 user manual — Commissioning of the inverter
17ページ · クリックして拡大
17ページ

Commissioning of the inverter

1. Make sure that the on/off button of the inverter is switched “off”. If the input voltage is provided by a supply unit, switch it off as well.
2. Connect the inverter to the DC voltage source with the delivered cables.
3. Connect the delivered power cable to the inverter (only for TSI-series)
4. Switch on the inverter.
5. only for TSI-Series: wait approx. 12 sec. until the inverter turns on.
6. Switch on all of the electronic devices one by one.

The connection process to the input DC voltage source leads to sparking because of the charging of the internal capacitors.

Sparking!

Page 18 of the Ective Energy TSI102 user manual — PARALLEL SERIES SERIES/PARALLEL
18ページ · クリックして拡大
18ページ

Possible configurations of batteries

If several batteries are used, there are various configuration possibilities of the battery banks depending on the inverter model (12 V, 24 V, 48 V).

  • Series connection (serial): voltages add up, capacity remains unchanged.
  • Parallel connection (parallel): capacities add up, voltage remains unchanged.
  • Series and parallel connection (serial and parallel): capacities and voltages add up.

Examples:

+ - + - + - + -

PARALLEL SERIES SERIES/PARALLEL

12 V/200 Ah 12 V/200 Ah 12 V/200 Ah 12 V/200 Ah

12 V + 12 V + 12 V + 12 V = 48 V Amp Hours remain at 200

+ - + - + - + -

12 V/200 Ah 12 V/200 Ah 12 V/200 Ah 12 V/200 Ah

Voltage remains at 12 V

200 Ah + 200 Ah + 200 Ah + 200 Ah = 800 Ah

+ - + - + - + -

12 V/200 Ah 12 V/200 Ah 12 V/200 Ah 12 V/200 Ah

+ - + - + - + -

12 V/200 Ah 12 V/200 Ah 12 V/200 Ah 12 V/200 Ah

Two strings of batteries in series are connected in parallel. The voltage increases to 48 V and the amp hours increase to 400 Ah

Page 19 of the Ective Energy TSI102 user manual — Safety features
19ページ · クリックして拡大
19ページ

Technical information

SI30 300 W 175 × 150 × 55 mm 1,3 kg

SI50 500 W 255 × 150 × 75 mm 2,5 kg

SI100 1000 W 370 × 150 × 75 mm 3,4 kg

SI150 1500 W 360 × 220 × 90 mm 5,1 kg

SI200 2000 W 385 × 220 × 90 mm 6,2 kg

SI250 2500 W 445 × 220 × 90 mm 6,9 kg

SI300 3000 W 425 × 220 × 150 mm 10,5 kg

SI400 4000 W 470 × 220 × 150 mm 11,5 kg

SI500 5000 W 480 × 220 × 150 mm 14,0 kg

SI600 6000 W 480 × 220 × 150 mm 14,5 kg

TSI50 500 W 290 × 150 × 75 mm 2,6 kg

TSI100 1000 W 370 × 150 × 75 mm 3,5 kg

TSI150 1500 W 400 × 220 × 90 mm 5,3 kg

TSI200 2000 W 450 × 220 × 90 mm 6,4 kg

TSI250 2500 W 490 × 220 × 90 mm 7,2 kg

TSI300 3000 W 500 × 220 × 150 mm 10,8 kg

Safety features

The inverter is equipped with several safety features to protect the inverter and all its components as for example the batteries.

The inverter is equipped with a thermic and electronic over-/undervoltage protection. If the value is far below or far above the required limit, the device shuts itself down auto matically and has to be switched on again using the on/off button before its restart.

In the following situations the inverter shuts itself down automatically:

Show 4 more labels / short text on this page
Model Power Dimensions · Empty weight · (LxWxH) · Restart necessary!
Page 20 of the Ective Energy TSI102 user manual — Technical information
20ページ · クリックして拡大
20ページ
  • internal temperature too high
  • required output load too high
  • input voltage too high or too low

Reason 12 V 24 V 48 V Action

risk of under voltage

10. 8V±0. 2V 21. 6V±0. 4V 43. 2V±0. 8V 2x acoustic signal + red LED flashing 2x every 8 sec. , inverter still working
10. 2V±0. 2V 20. 4V±0. 4V 40. 8V±0. 8V 3x acoustic signal + red LED flashes 3x every 8 sec. , automatic shutdown

overvoltage 15. 5V±0. 2V 31. 0V±0. 4V 62. 0V±0. 8V 4x acoustic signal + red LED flashing 4x every 8 sec. , automatic shutdown

overheating internal temperature >75°C 5x acoustic signal + red LED flashes 5x every 8 sec. , automatic shutdown

overload due to powerful consumers

regardless of the type red LED flashes con stantly until the error is solved and device is switched on again

short circuit of consumers

regardless of the type red LED flashes constantly until error is solved and device is switched on again

polarity reversal regardless of the type the fuses blow

11V±0. 2V 22V±0. 4V 44V±0. 8V shift to mains priority circuit

Damages caused by polarity reversal and short circuits are excluded from liability.

total undervolt age · undervoltage ECO-Mode · Exclusion of liability

Page 21 of the Ective Energy TSI102 user manual — Self error correction
21ページ · クリックして拡大
21ページ

Self error correction

Symptom Possible reason Solution

  • inverter switched on

No input voltage. 1. check battery voltage

  • status LED does not flash
2. check input fuse
3. check all connections to battery
  • no acoustic signal
  • no output voltage

blown fuse due to polarity reversal

Exchange blown fuses and connect cables correctly.

(Cautionpolarity reversal can damage the inverter despite a fuse)

If inverter does not work after exchange, it’s broken.

Please call the support!

Acoustic signal sounds once

1. connection to consumers cut off
1. check connection
2. check if short circuit
2. short circuit of consumers

acoustic signal sounds 2x and red LED flashes 2x every 8 sec.

possible undervoltage (see table)

1. check charging status of battery, charge if necessary
2. check compatibility of battery cable, use higher cross section if necessary
3. check if conductive parts (cables, pole termi nals, lugs) are damaged
Page 22 of the Ective Energy TSI102 user manual — ⚠ ⚠ Caution!
22ページ · クリックして拡大
22ページ

Symptom Possible reason Solution

acoustic signal sounds 3x and red LED flashes every 8 sec.

total undervoltage (see table)

1. check charging status of battery, charge if necessary
2. check compatibility of battery cable, use higher cross section if necessary
3. check if conductive parts (cables, pole termi nals, lugs) are damaged

acoustic signal sounds 4x and red LED flashes every 8 sec.

input voltage too high (see table)

1. check voltage
2. check charging voltage of battery charger
3. check if there are un wanted voltage sources

acoustic signal sounds 5x and red LED flashes 5x every 8 sec.

inverter overheated check ventilation, if damaged, call support

check if ventilations slits are free

check if ambient air is cool enough

red LED flashes permanently

maximum short-term power reached

⚠ ⚠ Caution!

Immediately eliminate error sources!

Make sure that error sources are eliminated. Multiple restarts due to unsolved errors can destroy the inverter.

Especially prevent short circuits and polarity reversals because they can destroy the device despite protection.

Show 4 more labels / short text on this page
reduce power · switch off inverter · reduce power · cool down inverter
Page 23 of the Ective Energy TSI102 user manual — Guarantee
23ページ · クリックして拡大
23ページ

Guarantee

The statutory warranty period shall apply. In case of complaints, please contact the office located in your country or the point of sale.

In order to receive a quick response to your guarantee request, please send the follow ing documents.

  • copy of invoice with purchase date
  • justification of complaints or error description

In the following cases the liability for damage is excluded:

  • damage of the device caused by overvoltage and mechanical impacts
  • mounting and connection errors
  • inappropriate use of the device
  • modification of the device without permission of the producer
Page 24 of the Ective Energy TSI102 user manual — Disposal
24ページ · クリックして拡大
24ページ

Disposal

Please recycle or dispose of the packaging material for this product.

The german Electronic Equipment Act (ElektroG) regulates how to place electronic devices on the market, how to recycle and dispose of them.

In case of decommissioning of the device, please contact the nearest recycling centre or point of sale in order to get information about the disposal regulations.

Page 25 of the Ective Energy TSI102 user manual — Disposal
25ページ · クリックして拡大
25ページ
Ective Energy TSI102 — Disposal diagram (page 25)
図 12 · Disposal

© 2017 Batterium GmbH, Auflage/Edition 2, 02/2017

batterium GmbH Mauserstraße 6 71640 Ludwigsburg Germany

Tel. : +49 7141 5609046 Fax: +49 7141 5609049

www. batterium. de

トラブル解決

トラブルシューティング

よくあるトラブル、考えられる原因、対処法。

問題考えられる原因対処法
• inverter switched on • status LED does not falsh • no acoustic signal • no output voltageNo input voltage.1. check battery voltage 2. check input fuse 3. check all connections to battery p.21
• inverter switched on • status LED does not falsh • no acoustic signal • no output voltageblown fuse due to polarity reversal (Caution: polarity re- versal can damage the inverter despite a fuse)Exchange blown fuses and connect cables correctly. If inverter does not work after exchange, it’s broken. Please call the support! p.21
Acoustic signal sounds once1. connection to consumers cut off 2. short circuit of consumers1. check connection 2. check if short circuit p.21
acoustic signal sounds 2x and red LED falshes 2x every 8 sec.possible undervoltage (see table)1. check charging status of battery, charge if necessary 2. check compatibility of battery cable, use higher cross section if necessary 3. check if conductive parts (cables, pole termi­ nals, lugs) are damaged p.21
acoustic signal sounds 3x and red LED falshes every 8 sec.total undervoltage (see table)1. check charging status of battery, charge if necessary 2. check compatibility of battery cable, use higher cross section if necessary 3. check if conductive parts (cables, pole termi­ nals, lugs) are damaged p.22
acoustic signal sounds 4x and red LED falshes every 8 sec.input voltage too high (see table)1. check voltage 2. check charging voltage of battery charger 3. check if there are un­ wanted voltage sources p.22
acoustic signal sounds 5x and red LED falshes 5x every 8 sec.inverter overheatedcheck ventilation, if damaged, call support check if ventilations slits are free check if ambient air is cool enough reduce power p.22
red LED falshes permanentlymaximum short-term power reachedswitch off inverter reduce power cool down inverter p.22

Ective Energy TSI102について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Ective Energy TSI102に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Ective Energy TSI102 取扱説明書(PDF)

56 ページ·287 KB·充電器·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…