920-075-08 (10-06) VERT -I-P AK ® A -SERIES SINGLE P A CKA GE VERTICAL AIR CONDITIONING SY STEM 9,000 - 18,000 BTU/h INS T ALL A TION & OPERA TION GUIDE.
2 T a ble of Content s 920-075-08 I. Gener al Speci fi cati ons Ins talla ti on Rec ommenda tion s ................................................................................................ .......................................... 3 Model Number Identi fi ca ti on Guide .
3 920-075-08 V er t-I- Pak Ins t allation Recommendations For proper unit per f ormance and ma ximum oper ating life please r efer to the minimum ins tallation clearances below . The abo ve sugges tions ar e for re fere nce only a nd do no t represe nt al l possibl e instal latio ns.
4 920-075-08 Section I. Genera l Speci fi cations Ver t-I - Pak ® Model Identi fi cation Guide Ver t-I - Pak ® Chassis Speci fi cat ions M O D EL : V( E , H) A0 9 V(E ,H )A 12 V(E ,H )A 18 V oltage ( V) 230 / 2 08 230 / 2 08 230 / 2 08 Refr ige rant R-22 R-2 2 R-2 2 Chassis Width 23.
5 920-075-08 To p V i e w Fig ure 4 II. Instal lati on 1 ) Utilit y Closet Dimensions Recommended ut ility c loset dimensions and a ty pical indoor inst al lation are illustrated in Figure 3. T hree inches minimum cl ear ance on three sides of the unit must be allowed for return air fl ow , installation ac ce s s and ser vice ac ce s s.
6 920-075-08 2 ) W all Plenum and Ar chitectural L ou ver Installation A . Inst all the wall plenum ( VP A WP1 - 8/1- 1 4 ) comp onents in acc ordanc e with t he in st al la tion instruct ions provided with each ac ces sor y .
7 920-075-08 3) E l e c t r i c a l D a t a Sample Name plate ( see your chas sis name plate ) Ele ctrica l D ata V oltage ( V) 230/208 230/208 230/208 230/ 20 8 230/208 230/20 8 230/208 230/20 8 230/208 LR A - C omp. (A) 21 21 21 24.0 24.0 24.0 47 47 4 7 Cool ing Curr ent (A) 4.
8 920-075-08 Elect rical Requir ement s Fi gure 6 3 ) Elect rical Data ( continued ) Electri ca l Ra tin g T ab les NOTE: Use copper conductors ONL Y .
9 920-075-08 Elect rical & Ther mostat W iring Diagrams 3 ) Elect rical Data ( continued ) Note: the diagram abov e illustrates the t ypic al thermo stat wir ing and 208 volt tr ansformer wir ing. See the unit co ntrol panel for the actual unit wir ing diagram and schematic.
10 920-075-08 4 ) Indoor Return A ir Grille Ins tallation There are t wo Indoor Return A ir Grille options as show n in Figure 8. Choose the option t hat best suits your needs. Use the in stallation instruc tions provided with ac c essor ies for installati on details.
11 920-075-08 5 ) Duct work Prepa ratio n 1) D u c t E S P : T o d e t e r m i n e y o u r s y s t e m ' s i n d o o r e x t e r n a l s t a t i c p r e s s u r e (ESP , in inches of water) use a duct calculator ( as provided b y y o u r d u c t s u p p l i e r ) .
12 920-075-08 CAUTION The unit basepan has t hree (3 ) provisions (lef t , right , and rear) for connec ting an ex ternal c ondens ate drain. A fi eld supplied co ndensate drain system must be co nnecte d to one of the t hree (lef t , right , or rear) 3/4" FPT c onnec tions on t he unit basepan.
13 920-075-08 III. Cha s sis Operation 9 ) Remote Thermost at Cont rol The chassis require s a simple single stage heat- co ol wall ther mostat. Each chassis c o mes with a ter minal st rip loc ated in t he electr ic al control box. A ll internal chassis wir ing (low & high voltage ) is fac tor y ready for 230 V olt operation.
14 920-075-08 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.friedr ich.com VERT-I-PAK ® A SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS LIMITED WARRANTY SAVE THIS CERTIFICA TE. It gives you spec ific rights, you may also have other rights w hich may vary from state to state and province to province.
15 920-075-08 V . V er t-I -Pak Access ories ACCESS P A NEL / R ETU RN A IR GR ILLE – Ser ves as an acc ess panel to c hassis and inter ior return air gr ille. A fi eld- supplied (25" x 20") fi lter is mounted inside the hinged acc ess do or .
920-075-08 (10-06) FRIEDRICH AIR CONDITIONING CO. INC. Post Office Box 1540 · San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 www .
デバイスFriedrich A-SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich A-SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich A-SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich A-SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich A-SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich A-SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich A-SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich A-SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich A-SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。