FriedrichメーカーMR09Y3Hの使用説明書/サービス説明書
ページ先へ移動 of 23
Models MW09Y3H Indoor Units Outdoor Units MR09Y3H MW12Y3H MR12Y3H Service and Parts Manual.
FRIEDRICH AIR CONDITIONING CO. 10001 Reunion Place, Ste. 500, San Antonio, TX 78216 (210) 546-0500 877-599-5665 x 261 F AX (210) 546-0630 Email: tac@friedrich.
2 S P E C I F I C A T I O N S TYPE Cool & heat inverter INDOOR UNIT MW12Y3H OUTDOOR UNIT MR12Y3H COOLING CAPACITY 11,500 BTU/h (3.40 kW) HEATING CAPACITY 14,000BTU/h (4.11 kW) POWER SOURCE 208 / 230 V FREQUENCY 60 Hz RUNNING CURRENT MAXIMUM CURRENT 4.
3 D I M E N S I O N S unit : inch (mm) 11-1/32 (280) 7-25/32 (198) 31-3/32 (790) INDOOR UNIT Refrigerant pipe length Liquid : 15-3/16 inch (386 mm) Gas : 12-15/16 inch (329 mm) Drain hose length : 23-5/8 inch (600 mm) Drain pipe diameter Inside : 5/8 inch (15.
4 R E F R I G E R A N T S Y S T E M D I A G R A M 2-Way valve Strainer Strainer 3-Way valve Muffler 4-Way valve Expansion valve Refrigerant direction Heat exchanger (indoor unit) Heat exchanger (outdoor unit) Compressor Cooling flow Heating flow Refrigerant pipe diameter Liquid : 1/4" (6.
5 RED WHITE WHITE WHITE WHITE WHITE WHITE BLUE YELLOW WHITE BLACK RED BLACK BLACK BLACK BLACK BLUE PINK YELLOW ORANGE RED GREEN RED WHITE BLACK CN1 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 1 .
6 BLACK BLACK BLACK BLACK RED ORANGE YELLOW PINK BLUE RED WHITE WHITE WHITE WHITE WHITE WHITE RED BLACK WHITE YELLOW BLUE 6 5 4 3 2 1 1 2 3 4 5 6 7 8 1 2 3 4 5 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 1 2 3 4 5 6 7 THERMISTOR ( PIPE TEMP . ) THERMISTOR ( ROOM TEMP .
7 P32 P70 P71 P72 P73 P74 P75 P33 P63 P62 P61 P60 VDD VSS C X1 X2 MD0 123 P 124 P 120 P 140 P 130 P AV DD AV SS RST P40 P41 P00 P01 P20 P21 P22 P23 P24 P25 P26 P27 P10 P11 P12 P13 P14 P15 P16 P17 P30 P31 12 11 10 9 8 7 6 5 4 3 2 1 25 26 27 28 29 30 31 32 33 34 35 36 13 14 15 16 17 18 19 20 21 22 23 24 48 47 46 45 44 43 42 41 40 39 38 37 C24 0.
8 5V 5V 5V + I C201 GP1UM261RKVF R202 47 <1/4W> C202 47/ 10V C203 0.1 <F> SW201 KSHG061 1BT CN201 07 JB20 / GIC 1061 L=230 A A A A 1 2 3 4 5 6 7 2 1 3 VCC OUT GND D201 SLR-343MC <GREEN&.
9 RED BLACK WHITE YELLOW BROWN BLACK BLACK RED BROWN BLUE ORANGE YELLOW WHITE UL3271 A WG16 x 3 RED WHITE BLACK C. M. COMPRESSOR 4-WA Y VAL VE COIL F . M. DC FAN MOT OR EXP ANSION V AL VE M 1 2 3 4 5 6 7 1 2 1 2 3 4 1 2 3 1 2 3 4 5 6 CN40 B6B-XARK-1-A RED CN800 B5 ( 7-2.
10 D64 1SS355 + C69 100/ 25V -12V C70 0.1 <F> + C67 0.1 <F> + C65 470/ 25V + C68 100/ 25V 5V 12V R61 10k <1/10W> I C60 BA17805 D54 1SS355 C64 330/ 25V + 1 2 3 I O G D62 D1FL20U D61 D1FL20U D60 D1FL20U 15V R31 1 8.66k 1% R309 5.76k 1% R310 143 1% C84 0.
1 1 E R R O R D E T E C T I O N Error Operation LED Coil dry LED Timer LED Serial signal error Off 2 flash off off off off off off off off off off off off off off off off off off off off 3 flash 4 fla.
12 P A R T S 2 3 1 7 8 9 4 4 5 5 INDOOR UNIT Front panel assy 4 Air Filter 1 Front Panel Assy 5 3 Clamper (Grille) Intake Grille Assy Panel Cover -- Wire Cover -- Wire Shield 7 Remote Control 8 9 Remote Control Holder Ref.
13 11 13 16 14 15 17 12 11 Evaporator Total Assy 17 Room Thermistor Holder 12 Joint Pipe Assy 13 Filter Guide 15 14 Evaporator Holder R 16 Evaporator Holder L Rear Bracket Ref.
14 41 28 32 31 33 34 27 39 29 30 40 23 21 35 42 37 36 24 38 INDOOR UNIT Casing assy 27 Fan Guard 37 Fan Motor 38 Crossflow Fan Assy 39 Shaft Holder C 40 Louver U 41 Louver Z 30 Conduit Holder 42 Bracket Panel 34 Motor Step 23 Drain Hose Assy 24 Drain Cap Ref.
15 52 53 51 57 56 59 54 INDOOR UNIT Control box 56 Display PCB Assy 54 Controller PCB Assy (09) 54 Controller PCB Assy (12) 59 Earth Terminal 58 Terminal 57 Control Box -- Thermistor Assy 51 Box Shield Assy 52 Control Cover 53 Cover Shield Assy Ref.
16 P A R T S 1 1 2 9 12 3 15 14 10 13 11 5 6 7 8 4 OUTDOOR UNIT MR09Y3H MR12Y3H 4 Top Panel Assy 1 Front Panel Assy 5 Protective Net 3 6 Cabinet Left Assy 2 Emblem Switch Cover 8 Valve Bracket 7 Cabin.
17 OUTDOOR UNIT MR09Y3H 21 24 22 25 29 27 26 30 28 24 Compressor Assy 26 3 way Valve Assy 29 Pulse Motor Valve Assy -- Solenoid 22 Condenser Total Assy 30 Expansion Valve Coil 27 Muffler 28 4 way Valve 25 2 way Valve Assy 21 Base Assy Ref.
18 21 24 22 25 29 27 26 30 28 OUTDOOR UNIT MR12Y3H 24 Compressor Assy 26 3 way Valve Assy 29 Pulse Motor Valve Assy -- Solenoid 22 Condenser Total Assy 30 Expansion Valve Coil 27 Muffler 28 4 way Valve 25 2 way Valve Assy 21 Base Assy Ref.
19 33 34 32 31 36 37 38 39 OUTDOOR UNIT MR09Y3H MR12Y3H -- Outdoor Thermistor 36 Terminal Bracket 37 Terminal 5P 38 Terminal Cover Assy 39 Bracket Conduit 34 Controller PCB Assy (09) Controller PCB Assy (12) -- Thermistor Assy 31 Sealed Panel 32 Inverter Case Assy 32 33 PCB Holder Ref.
20 67201533 Remote control holder 67202078 67202007 Remote control Wall hook bracket A C C E S S O R I E S.
.
FRIEDRICH AIR CONDITIONING CO. 10001 Reunion Place, Ste. 500, San Antonio, TX 78216 (210) 546-0500 877-599-5665 x 261 F AX (210) 546-0630 Email: tac@friedrich.
デバイスFriedrich MR09Y3Hの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Friedrich MR09Y3Hをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFriedrich MR09Y3Hの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Friedrich MR09Y3Hの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Friedrich MR09Y3Hで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Friedrich MR09Y3Hを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFriedrich MR09Y3Hの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Friedrich MR09Y3Hに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFriedrich MR09Y3Hデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。