ページ先へ移動 of 12
Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Parts List: page 5 Kits: page 6 Torque Specifications: page 6 Repair Instructions: pages 7-10 Dimensions: .
2 INST ALLA TION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc.
90 85 80 75 70 0 2900 5800 8700 1 1,600 Pressure (PSI) Decibels 750 RPM 500 RPM 1400 = hp V olume ........................................................................................................ U p t o 9.9 GPM Dischar ge Pressure ............
Exploded View - GP7122 4 Must be on inlet connection side. See note on pg. 2..
GP7122 PARTS LIST ITEM PART DESCRIPTION QTY. 1 07600 Crankcase 1 2 13000 Oil Filler Plug Assembly 1 4 07601 Crankcase Cover 1 5 07602 Seal for Crankcase Cover 1 8 07603 Oil Dip Stick 1 9 06225 O-Ring,.
Position Item# Description T orque Amount 24 13406 Inner Hexagon Screw 30 (ft.-lbs.) 36 13138 Plunger 33 (ft.-lbs.) 49A 13160 Nut 103 (ft.-lbs.) 58C 07702 Hexagon Screw 155 (ft.-lbs.) GP7122 TORQUE SPECIFICA TIONS Inlet V alve Assembly Kit #09552 Item Part # Description Qty .
NOTE: Always take time to lubricate all metal and non-metal parts with a light film of oil before reassembling. This step will help ensure proper fit, at the same time protecting the pump non-metal parts (elastomers) from cutting and scoring. GP7122 REP AIR INSTRUCTIONS 1) Lossen and remove screws (58C) with a 24mm socket wrench.
7) When reassembling: The inlet valve seat (51C) is 1mm smaller in diameter than the dischar ge valve seat (52C). Inlet valve seats are marked "S" and always have to be installed first. Discharge valve seats are marked "P" and are always to be installed on top of inlet valve.
1 4) Remove circlip ring (48) from seal sleeve (38). Re- move spacer disc (47) and seal ring (46) from seal sleeve. Replace worn or damaged parts. CAUTION: Don't loosen the 3 plunger (36) before the valve casing has been removed otherwise the plunger (36) could hit against the spacer pipe (51F) when the pump is being turned.
10 GP7122 REP AIR INSTRUCTIONS TO ASSEMBLE V A L VE CASING 18. Check O-rings (39A) and support rings (39B) on seal case (39). Clean surfaces of seal sleeves (38) in crankcase (1) and sealing surfaces of valve casing (50). Insert seal sleeve with plunger into crankcase guide.
59 260 476.5 141.5 690 165 85 85.5 GP7122 Dimensions (Inches) 11 300 227 584 330 340 93 312.5 48kb 515.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
デバイスGiant GP7122の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP7122をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP7122の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP7122の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP7122で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP7122を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP7122の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP7122に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP7122デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。