INSTRUCTIONS-PARTS LIST This manual contains IMPORTANT WARNINGS and INSTRUCTIONS READ AND RETAIN FOR REFERENCE HYDRA-CLEAN @ 826,1235 Pressure Washers HYDRA-CLEAN 826 Model 800-093, Series B 800 psi (.
WARNING HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD General Safety This pressure washer generates very high fluid pressure.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION (826) The 826 pressure washer is provided with a ground-fault circuit-interrupter (GFCI) built into the power supply cord.
High pressure fluid in the hoses can be very dangerous. If the hose develops a leak, split or rupture due to any kind of wear, damage or misuse, the high pressure spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage.
PUMP OIL LEVEL INDICATOR WINDOW WATER I CONNECTION -,-.. a-----. MOTOR SWITCH / ELECTRIC PLUG S/4” UAHDEN HOSE (f) INLET FILTER PUMP DIPSTICK ADJUSTABLE NOZZLE (826) HIGH SPRAY - GUN CONNECTION QUICK HIGH PRESSURE SPRAY HOSE Figure 1 Check for Shipping Damage Check the unit for any damage that may have occurred in shipping.
Use this procedure whenever starting the pressure washer to help insure that the unit is ready to operate and starting is done safely. 1. Check the oil level. Pump: Add SAE 20 or 30 weight non-detergent oil as necessary. 2. Turn on the water supply. Never run the unit dry.
Trigger Safety Latch WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, ALWAYS engage the trigger safety latch whenever spraying stops, even for a moment.
SHUTDOWN, FLUSHING AND STORAGE WARNING Pressure Relief Procedure To reduce the risk of serious bodily injury, including fluid injection and splashing in the eyes, or on the skin, always follow this procedure whenever you stop spraying for more than 10 minutes, when shutting down, and before checking or repairing any part of the system.
TROUBLESHOOTING CHART WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warning before proceeding.
To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or NOTE: The following metric wrenches are needed: MlO, Ml3 and M30. Repair kits are available. Refer to the individual repair sections and the pump parts page for more details.
Servicing the V-Packings NOTE: There are two types of packing kits: one is just packings, the other includes the packings, rings and retainers. 5. Thoroughly clean the packing cavities and examine.
800-093 Hydra-Clean@ 826 Pressure Washer 115 VOLT, 1 PHASE -- ,.- 27 / 26 -- 32 WHT -I--- BLK GRN * yL-EL MOTOR / 69 ~~ WIRING BOX T8 - 12 308-518.
800-093 Hydra-Clean@ 826 Pressure Washer REF NO. 1 5 z 6 7 PART NO. 801-683 803-059 801-881 801-901 801-023 801-025 801-940 801-900 803-486 801-905 801-907 801-865 801-880 801-890 801-891 i; 18 19 20 .
PARTS DRAWING 800-268 Hydra-Clean@ 1235 Pressure Washer 62 MOTOR 230 VOLT, 1 PHASE 5 37 . 56 57 58 59 ,/----7 39 16 1 I / ' I b' / / 50 i ,’ I I I I L i *-79 i 17 I %- 17 1 L lb----+ ---.
800-268 Hydra-Clean@ 1235 Pressure Washer REF PART NO. NO. 1 800-394 2 801-090 3 801-007 4 801-009 5 402-278 6 800- 135 7 800- 134 8 800-060 9 800-061 10 801-012 11 801-541 12 800-374 13 803-350 14 80.
PARTS DRAWING 800-154 Pump and Motor Assembly PARTS LIST 800-154 Pump and Motor Assembly REF PART NO. NO. 1 801-862 2 801-864 3 801-870 4 801-871 2 801-872 801-023 i 801-139 801-015 9 801-363 10 802-818 11 801-887 12 801-l 37 DESCRIPTION MOTOR, 1.
PARTS DRAWING 800-248 Pump and Motor Assembly PARTS LIST 800-248 Pump and Motor Assembly REF PART NO. NO. 1 802-625 2 802-629 3 802-633 2 802-698 802-786 6 801-139 7 802-784 8 802-785 9 801-887 10 801-137 DESCRIPTION QTY MOTOR, 3.
PARTS DRAWING 802-285 Pump Assembly, 800 psi 18 I I I 7 11-i 6 I 14 - d 1 I I 18 308-518.
PARTS LIST 802-265 Pump Assembly, 800 psi REF NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 PART NO. DESCRIPTION 801-899 MANIFOLD, Aluminum 802-795 MANIFOLD, Brass 801-651 SCREW, Cap, socket hd.
PARTS DRAWING 802-629 Pump Assembly, 1200 psi I I 20 308-518.
802-629 Pump Assembly, 1200 psi REF NO. 1 2 3 4 5 6 ; 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PART NO. DESCRIPTION 802-319 MANIFOLD, 1200 psi 801-651 SCREW, Cap, socket hd.
ACCESSORIES (Must be purchased separately) DOWNSTREAM CHEMICAL INJECTOR KIT (1235) 800-l 11 For injecting harsh cleaning chemicals downstream from the pump. UPSTREAM CHEMICAL INJECTOR KIT 600-257 For injecting mild cleaning chemicals upstream into the pump.
.
THE GRACO WARRANTY WARRANTY AND DISCLAIMERS Grace warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Grace distributor to the original purchaser for use.
デバイスGraco Inc. 800-268の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Graco Inc. 800-268をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGraco Inc. 800-268の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Graco Inc. 800-268の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Graco Inc. 800-268で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Graco Inc. 800-268を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGraco Inc. 800-268の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Graco Inc. 800-268に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGraco Inc. 800-268デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。