Page 1 of 2 7 3/8" Aperture (2) Quad Tube Cross Blade Louver

11 3/8" (289 mm)
5 3/4" (146 mm)
12 1/2" (318 mm)
1" (25 mm) min.- 2 1/8" (54 mm) max.

Features 1. Reflector: 16 ga. Die-formed aluminium, Anobrite® finish. 2. Socket Cup: Die-cast zinc cup effectively dissipates heat and positions lamp holder. Snaps onto reflector neck to assure consistently correct optical alignment without tools. 3. Mounting Frame: Die-cast aluminum for dry or plaster ceilings. Accepts other 7" quad tube reflectors. 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or 1 1/2” lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools. 7. Cross Blade Louver: Die-formed, 16 ga. Aluminum, matte white or painted aluminum finish. Accepts lens (consult factory). 50° cut-off to lamp, medium beam. Keyed for orientation.
Options and Accessories (continued) Emergency Ltg. Kit FA EM3E*(4 pin) FA EM4E*(4 pin) FA EM2T*(2 pin) Fuse (Slow Blow) Add suffix F *See Spec. Sheets: FAEC, FAEM
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels UL listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA. US Patent Pending.
Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.

UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90°C supply conductors.
Emergency Add suffix EM* Chicago Plenum Add suffix LC Existing/Thk. Ceiling FA EC7*
15" (381 mm)

Page 2 of 2 7 3/8" Aperture (2) Quad Tube Cross Blade Louver
26W
Spacing Ratio = 0.8
CERTIFIED TEST REPORT NO. LSI 12561 CALCULITE COMPACT FLUORESCENT DIFFUSE REFLECTOR WITH WHITE PAINTED 4 CELL LOUVER 2-18W SYLVANIA DULUX D/E FLUORESCENT LAMPS, LUMEN RATING = 1250 LMS.

CANDLEPOWER ANGLE ALONG 22.5 45 67.5 ACROSS LUMENS 0 513 5 525 511 504 495 495 48 10 513 495 481 466 461 15 477 453 439 422 415 122 20 430 406 380 364 358 25 375 354 329 305 303 151 30 325 296 271 247 247 35 253 233 183 193 198 133 40 188 169 155 148 148 45 128 118 109 109 103 88 50 82 56 76 78 74 55 53 61 58 57 58 54 60 50 48 46 45 46 65 39 37 36 35 35 36 70 29 28 27 26 26 75 20 19 19 18 18 20 80 12 12 12 11 11 85 6 6 5 5 5 90 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 321 12.88 48.92 0-40 454 18.18 69.08 0-60 595 23.82 90.52 0-90 657 26.32 100.00 40-90 203 8.14 30.92 60-90 62 2.49 9.48 90-180 0 .00 .00 0-180 657 26.32 100.00
Coefficients of Utilization
Coefficients of Utilization

20% FLOOR CAVITY REFLECTANCE Conversion Factors: Aluminum Cross Blade, C.U. x 0.7.
180 150 120 · Across · 45 Along