Page 1 of 2 4 1/2” Aperture PAR20/PAR16/BR19/R20 Reflector Trim


1/2" to 1" Thk. Ceiling
1 1/4" Max. Ceiling Thk.
* 7 3/4" min. is for up to 3/4" thick ceiling
C4P20DCLW / C4A120 C4P20DCLW / C4120 or 4 1/2" Dia. 5 3/4" Dia.
Ceiling Cutout: 5 1/16" (129 mm) Dia.

Features 1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image. Available with painted white or polished flange. Interchangeable with other Evolution 4 1/2" line voltage trims. 2. Socket Harness: Spring tension clips snap into die-cast aluminum top at pre-focused positions ensuring correct optical alignment. Medium base porcelain socket with nickel plated screw shell, No. 18 SF-1 leads, and keyed plug-in quick connector for power connection to junction box. 3. Frame-In-Kit: Compatible Frame-In Kits are listed above; see separate specification sheet for details. Non-IC and Non-IC AirSeal® - Insulation must be kept 3” away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. IC-AirSeal® - Fixture may be in direct contact with insulation.
Labels UL Listed (suitable for damp locations), I.B.E.W.
Alzak® is a registered trademark of ALCOA. US and Foreign Patents Pending.

1Specify desired flange W White, P Polished
9 1/4"

Page 2 of 2 4 1/2” Aperture PAR20/PAR16/BR19/R20 Reflector Trim
Spacing Ratio = 0.6
Spacing Ratio = 1.0
Certified Test Report No. 0838FR Computed By LSI Program **Test-Lite**
Certified Test Report No. 0839FR Computed By LSI Program **Test-Lite**
Recessed Open Reflector Downlight 4 1/2" Dia. Aperture, Specular Clear Finish Reflector 50W PAR20 NFL Sylvania Lamp. Lumen Rating = 530 LMS.
Recessed Open Reflector Downlight 4 1/2" Dia. Aperture, Specular Clear Finish Reflector 75W R20 GE Lamp. Lumen Rating = 650 LMS.

Candlepower Summary Angle Mean CP Lumens 0 1423 5 1186 115 10 1036 15 878 238 20 565 25 259 135 30 84 35 26 23 40 12 45 3 4 50 0 55 0 0 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0

Candlepower Summary Angle Mean CP Lumens 0 479 5 479 46 10 489 15 508 142 20 500 25 447 199 30 328 35 197 131 40 110 45 25 32 50 3 55 1 1 60 0 65 0 0 70 0 75 0 0 80 0 85 0 0 90 0
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 448 92.09 94.76 0-40 511 96.49 99.28 0-60 514 97.17 99.98 0-90 515 97.19 100.00 40-90 3 .70 .72 60-90 0 .02 .02 90-180 0 .00 .00 0-180 515 97.19 100.00
Zonal Lumens And Percentages Zone Lumens % Lamp %Luminaire 0-30 387 59.60 70.37 0-40 518 79.69 94.09 0-60 550 84.69 99.99 0-90 550 84.70 100.00 40-90 32 5.01 5.91 60-90 0 .01 .01 90-180 0 .00 .00 0-180 50 84.70 100.00
** Efficiency = 97.2% **
** Efficiency = 84.7% **
Tested According To IES Procedures. Test Distance Exceeds Five
Tested According To IES Procedures. Test Distance Exceeds Five
Times The Greatest Luminous Opening Of Luminaire.
Times The Greatest Luminous Opening Of Luminaire.
Coefficients of Utilization % Effective Ceiling Cavity Reflectance 80 70 50 30 10 0 % Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 1.11 1.09 1.08 1.09 1.07 1.06 1.05 1.04 1.03 1.01 1.01 1.00 .98 .98 .97 .95 2 1.06 1.04 1.02 1.05 1.02 1.01 1.02 1.00 .98 .99 .98 .96 .97 .96 .94 .93 3 1.03 1.00 .97 1.01 .99 .97 .99 .97 .95 .97 .95 .94 .95 .94 .93 .91 4 1.00 .96 .94 .99 .96 .93 .97 .94 .92 .95 .93 .91 .93 .92 .90 .89 5 .96 .93 .90 .95 .92 .90 .94 .91 .89 .92 .90 .88 .91 .89 .88 .87 6 .94 .90 .88 .93 .90 .88 .92 .89 .87 .91 .88 .87 .90 .88 .86 .85 7 .91 .88 .85 .91 .87 .85 .89 .87 .85 .88 .86 .84 .88 .85 .84 .83 8 .88 .85 .83 .88 .85 .82 .87 .84 .82 .86 .84 .82 .86 .83 .81 .81 9 .86 .83 .80 .86 .83 .80 .85 .82 .80 .84 .81 .80 .84 .81 .79 .79 10 .84 .81 .78 .84 .81 .78 .83 .80 .78 .82 .80 .78 .82 .79 .78 .77 20% Floor Cavity Reflectance
Coefficients of Utilization % Effective Ceiling Cavity Reflectance 80 70 50 30 10 0 % Wall Reflectance 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .95 .93 .92 .94 .92 .90 .90 .89 .88 .87 .86 .85 .84 .83 .83 .81 2 .90 .87 .85 .88 .86 .84 .86 .84 .82 .83 .82 .80 .81 .80 .79 .77 3 .85 .82 .79 .84 .81 .78 .82 .79 .77 .80 .78 .76 .78 .76 .75 .74 4 .81 .77 .74 .80 .76 .73 .78 .75 .73 .76 .74 .72 .75 .73 .71 .70 5 .76 .72 .69 .75 .71 .69 .74 .71 .68 .73 .70 .68 .71 .69 .67 .66 6 .73 .68 .65 ..72 .68 .65 .71 .67 .64 .70 .66 .64 .68 .66 .64 .63 7 .68 .64 .61 ..68 .64 .61 .67 .63 .61 .66 .63 .60 .65 .62 .60 .59 8 .65 .60 .57 .64 .60 .57 .63 .60 .57 .63 .59 .57 .62 .59 .56 .55 9 .61 .57 .54 .61 .57 .54 .60 .56 .53 .59 .56 .53 .58 .55 .53 .52 10 .58 .53 .50 .57 .53 .50 .57 .53 .50 .56 .52 .50 .56 .52 .50 .49
20% Floor Cavity Reflectance
Conversion Factors 35W, 50W PAR20 NFL: Clear, C.U.x 1.0; Diffuse/Gold, C.U.x 0.95; Black, C.U.x 0.7 60W, 75W PAR16 NFL: Clear, C.U.x 0.90; Diffuse/Gold, C.U.x 0.85; Black, C.U.x 0.6 35W, 50W BR19 SP: Clear, C.U.x 0.85; Diffuse/Gold, C.U.x 0.80; Black, C.U.x 0.6
Conversion Factors 30W to 75W R20: Clear, C.U.x 1.00; Diffuse/Gold, C.U.x 0.9; Black, C.U.x 0.45
Room Cavity Ratio