Page 1 of the Lightolier C4X4MRW user manual — Notes:
1ページ · クリックして拡大
1ページ

Calculite ® Matrix Low Voltage Lensed Adj. Accent C4X4MRW

Page 1 of 2 4½" X 4½" Square Aperture (1) MR16 Low Voltage

5 6 9 8 7 1 2 3 10 4

9.66"

8.16"

2" Max. Ceiling Thickness 12"

9.66"

Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.

Frame-In KitsReflector Trims Finish/FlangeLamp C4X4LVMU Magnetic 120/277V C4X4LVE1 Electronic 120V C4X4LVE2 Electronic 277VC4X4MRWCLW Specul C4X4MRWCLP Specul C4X4MRWCCLW Comfo C4X4MRWCCLP Comfo C4X4MRWCCDW Comfo C4X4MRWCCDP Comfo C4X4MRWWHW Whitear Clear/White ar Clear/Polished rt Clear/White rt Clear/Polished rt Clear Diffuse/White rt Clear Diffuse/Polished /White(1) 12V MR16 Type Lamp 65W Max or IR 37W Max

Features 1. Reflector Trim: Available with integral flange in painted white or polished to match inside of cone. 2. Lamp Holder/Trim Adjustment Assembly: Unitized optics ensure alignment of lamp and aperture cone regardless of ceiling thickness. Patented EZ Aim™ gear-driven adjustment features an optimized lamp path to maximize light output at tilt angles up to 45°. Aiming indicator ensures accurate lamp positioning. Prismatic lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Ceramic body with mica cover, GX5.3 (MR-16) base. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 9. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 10. Transformer: Replaceable from below. Magnetic: 120/277V 60 Hz. Dual- voltage, core & coil. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.

Options and Accessories Accepts two optical accessories 2" diameter color filters/specialty filters: ADF2/AF2 2" diameter louver: AL2HC

Labels UL, cUL (Suitable for Wet Locations)

Job Name:

Cat. No.:

Lamp(s):

Notes:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • B0807

8" · Ordering Information

Page 2 of the Lightolier C4X4MRW user manual — 50W MR 16 40° FL
2ページ · クリックして拡大
2ページ
Lightolier C4X4MRW — Low Voltage diagram (page 2)
図 1 · Low Voltage

Calculite ® Matrix Low Voltage Lensed Adj. Accent C4X4MRW

Page of 2 4½" X 4½" Square Aperture (1) MR16 Low Voltage

(FC) is initial footcandles at center of beam. Beam length (L) and beam width (W) are to where the candlepower is reduced to 50% of the center beam candlepower. (C) is the distance to the center of the beam.

90° 4 ½" x 4 ½" Aperture 50W MR16 - 15°

Angle CP 0 87 5 136 10 278 15 713 20 1478 25 2537 30 3228 35 2577 40 1289 45 420 50 119 55 12 60 0 65 0 70 0 75 0 80 0 85 0 90 0

50W MR 16 15° SP

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 58 2.1' 1.8' 8' 4.6' 33 2.8' 2.4' 10' 5.8' 21 3.5' 3.0' 12' 6.9' 15 4.2' 3.6' 15' 8.7' 9 5.3' 4.6'

Lamp @ 30° Vertical Tilt

Lumen Rating = 800 LMS. CBCP = 3228 CD Beam Angle = 15° Test Report No. 3500FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 101 2.2' 1.1' 3' 5.2' 45 3.3' 1.6' 4' 6.9' 25 4.4' 2.1' 6' 10.4' 11 6.7' 3.2' 8' 13.9' 6 8.9' 4.2'

4 ½" x 4 ½" Aperture 50W MR16 - 25°

Angle CP 0 161 5 299 10 522 15 835 20 1204 25 1485 30 1553 35 1392 40 999 45 487 50 115 55 6 60 1 65 1 70 0 75 0 80 0 85 0 90 0

50W MR 16 25° FL

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 28 3.6' 3.1' 8' 4.6' 16 4.8' 4.1' 10' 5.8' 10 6.0' 5.1' 12' 6.9' 7 7.2' 6.1' 15' 8.7' 4 9.0' 7.7'

Lamp @ 30° Vertical Tilt

Lumen Rating = 800 LMS. CBCP = 1553 CD Beam Angle = 25° Test Report No. 3501FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 49 4.2' 1.8' 3' 5.2' 22 6.2' 2.7' 4' 6.9' 12 8.3' 3.5' 6' 10.4' 5 12.5' 5.3' 8' 13.9' 3 16.6' 7.1'

4 ½" x 4 ½" Aperture 50W MR16 - 40°

Angle CP 0 144 5 277 10 516 15 823 20 1107 25 1287 30 1320 35 1219 40 957 45 526 50 133 55 4 60 1 65 0 70 0 75 0 80 0 85 0 90 0

50W MR 16 40° FL

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 24 5.2' 4.4' 8' 4.6' 13 7.0' 5.8' 10' 5.8' 9 8.7' 7.3' 12' 6.9' 6 10.4' 8.7' 15' 8.7' 4 13.0' 10.9'

Lamp @ 30° Vertical Tilt

Lumen Rating = 800 LMS. CBCP = 1320 CD Beam Angle = 30° Test Report No. 3502FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 41 7.2' 2.5' 3' 5.2' 18 10.8' 3.8' 4' 6.9' 10 14.4' 5.0' 6' 10.4' 5 21.6' 7.6' 8' 13.9' 3 28.8' 10.1'

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • B0807
Show 8 more labels / short text on this page
60° · 0° 30° · 90° · 60° · 1400 0° 30° · 90° · 60° · 1400 0° 30°
Page 3 of the Lightolier C4X4MRW user manual — Notes:
3ページ · クリックして拡大
3ページ

Calculite ® Matrix HID Lensed Adj. Accent C4X4MRW

Page 1 of 1 4½" X 4½" Square Aperture (1) 20W CMH MR16

9.66"

8.16"

2" Max. Ceiling Thickness 5.75" 4.5"

9.66"

Ceiling Cutout: 5 1/4" x 5 1/4" (130 mm x 130mm) Dia.

Frame-In KitsReflector Trims Finish/FlangeLamp C4X420MREU Electronic 120/277VC4X4MRWCLW Specul C4X4MRWCLP Specul C4X4MRWCCLW Comfo C4X4MRWCCLP Comfo C4X4MRWCCDW Comfo C4X4MRWCCDP Comfo C4X4MRWWHW White/ar Clear/White ar Clear/Polished rt Clear/White rt Clear/Polished rt Clear Diffuse/White rt Clear Diffuse/Polished White(1) 20W MR16 CMH GXIC Base

Features 1. Reflector Trim: 55° physical and reflected cutoff. Available with integral flange painted white or polished to match inside of cone. 2. Lamp Holder/Trim Adjustment Assembly: Unitized optics ensure alignment of lamp and aperture cone regardless of ceiling thickness. Patented EZ Aim™ gear-driven adjustment features an optimized lamp path to maximize light output at tilt angles up to 45°. Aiming indicator ensures accurate lamp positioning. Solite lens ships standard. Adjust trim kit vertically to accommodate up to 2" thick ceiling. 3. Socket: Twist and lock base. 5kV (600V) pulse rated PPS, black T240 body socket with nickel-plated contacts. 18 AWG silicone leads with fiberglass outer sleeve. 4. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. Removable cover for top relamping. 5. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or ½" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside the fixture. 6. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 7. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 8. Ballast/Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement. 9. Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 10. Thermal Protector: Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. 11. Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor >0.99, THD

Features (continued)

Ballast ANSI Code Voltage Max. Amps Input Watts 20W MH M156 120/277V 0.20/0.09 22

Options and Accessories Accepts one optical accessory 2" diameter color filter/specialty filter: ADF2/AF2 2" diameter louver: AL2HC

Labels UL, cUL (Suitable For Wet Locations)

Job Name:

Cat. No.:

Lamp(s):

Notes:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0507

8" · Ordering Information

Page 4 of the Lightolier C4X4MRW user manual — 20W G.E.HID MR16 40° FL, GX10 BASE
4ページ · クリックして拡大
4ページ
Lightolier C4X4MRW — HID diagram (page 4)
図 2

Page 2 of 2 4½" X 4½" Square Aperture (1) 20W CMH MR16

(FC) is initial footcandles at center of beam. Beam length (L) and beam width (W) are to where the candlepower is reduced to 50% of the center beam candlepower. (C) is the distance to the center of the beam.

4 ½" x 4 ½" Aperture 20W CMH MR16 - 12°

Angle CP 0 117 5 166 10 297 15 644 20 1352 25 2138 30 2595 35 2154 40 1201 45 476 50 159 55 26 60 0 65 0 70 0 75 0 80 0 85 0 90 0

20W G.E.HID MR16 12° SP, GX10 BASE

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 47 1.7' 1.5' 8' 4.6' 26 2.3' 1.9' 10' 5.8' 17 2.8' 2.4' 12' 6.9' 12 3.4' 2.9' 14' 8.1' 9 3.9' 3.4'

Lamp @ 30° Vertical Tilt

Lumen Rating = 1000 LMS. CBCP = 2595 CD Beam Angle = 16° Test Report No. 3421FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 81 1.7' 0.8' 3' 5.2' 36 2.6' 1.3' 4' 6.9' 20 3.5' 1.7' 5' 8.7' 13 4.3' 2.1' 6' 10.4' 9 5.2' 2.5'

4 ½" x 4 ½" Aperture 20W CMH MR16-25°

Angle CP 0 165 5 210 10 335 15 628 20 1107 25 1630 30 1914 35 1730 40 1075 45 453 50 104 55 7 60 2 65 1 70 1 75 1 80 1 85 1 90 1

20W G.E.HID MR16 40° FL, GX10 BASE

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 35 3.1' 2.7' 8' 4.6' 19 4.2' 3.6' 10' 5.8' 12 5.2' 4.5' 12' 6.9' 9 6.3' 5.4' 14' 8.1' 6 7.3' 6.3'

Lamp @ 30° Vertical Tilt

Lumen Rating = 1000 LMS. CBCP = 1914 CD Beam Angle = 22° Test Report No. 3418FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 60 3.5' 1.6' 3' 5.2' 27 5.3' 2.3' 4' 6.9' 15 7.0' 3.1' 5' 8.7' 10 8.8' 3.9' 6' 10.4' 7 10.5' 4.7'

4 ½" x 4 ½" Aperture 20W CMH MR16-40°

Angle CP 0 134 5 241 10 417 15 676 20 940 25 1128 30 1214 35 1164 40 928 45 541 50 225 55 43 60 3 65 0 70 1 75 1 80 0 85 1 90 0

20W G.E.HID MR16 40° FL, GX10 BASE

30° Aiming Angle - Horizontal Surface D C FC L W 6' 3.5' 22 4.4' 3.7' 8' 4.6' 12 5.9' 5.0' 10' 5.8' 8 7.3' 6.2' 12' 6.9' 5 8.8' 7.4' 14' 8.1' 4 10.2' 8.7'

Lamp @ 30° Vertical Tilt

Lumen Rating = 1000 LMS. CBCP = 1214 CD Beam Angle = 30° Test Report No. 3416FR

30° Aiming Angle - Vertical Surface D C FC L W 2' 3.5' 38 5.5' 2.1' 3' 5.2' 17 8.2' 3.2' 4' 6.9' 9 10.9' 4.3' 5' 8.7' 6 13.7' 5.4' 6' 10.4' 4 16.4' 6.4'

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC
  • A0507
Show 6 more labels / short text on this page
60° · 30° · 60° · 2000 30° · 60° · 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C4X4MRWについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C4X4MRWに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C4X4MRW 取扱説明書(PDF)

4 ページ·470 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…