Page 1 of 2 6" Aperture, PAR30 Ceramic Metal Halide
20" (508 mm) to 30" (762 mm)
10 7/8" (276 mm)
20" (508 mm) to 30" (762 mm)
Vertical Adjustment:
3/4" (25 mm) to 2 7/8" (73 mm)
7-7/8" (181 mm) Dia. 5-3/4" (146 mm) Dia. 1 1/8" (29 mm) max. Ceiling Thickness
Ceiling Cutout: 6 9/16” (167 mm) Dia.
Reflector Trim Frame-In Kit Lamp C6P30MHA CLW Specular Clear, White Painted Flange. C6A39P30E1 Electronic 120V 39W PAR30 Ceramic MH CLP Specular Clear, Matching Flange. C6A39P30E2 Electronic 277V 39W PAR30 Ceramic MH CCDW Comfort Clear Diffuse, White Painted Flange. C6A70P38E1 Electronic 120V 70W PAR30 Ceramic MH CCDP Comfort Clear Diffuse, Matching Flange. C6A70P38E2 Electronic 277V 70W PAR30 Ceramic MH CCZP Champagne Bronze, White Painted Flange. C6A39P30U Magnetic 120V/277V 39W PAR30 Ceramic MH CCZW Champagne Bronze, Matching Flange. C6A70P38U Magnetic 120V/277V 70W PAR30 Ceramic MH
Features 1. Reflector Trim: Low brightness, specular anodized aluminum or with integral flange in painted white or polished to match inside of cone. 2. Lamp Holder Assembly: Unitized optics insure alignment of lamp and aperture cone. Integral C-shaped media holder accepts up to two 4 3/4"dia. medias. 3. Trim Adjustment Mechanism: Provides 40° vertical tilt, 360°+ horizontal rotation; lockable. Patented EZ-Aim Helical Drive System provides fast and accurate hot aiming with Philips screwdriver. 4. Socket: Medium base porcelain pulse rated socket with nickel plated screwshell. 5. Frame Housing: Steel, 0.029" (22-Ga.), matte black finish. 6. Frame Vertical Adjustment Mechanism: Accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from below from inside fixture. 7. Mounting Bars: Galvanized steel, 0.048" (18-ga.), pre-installed telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 8. Retention Springs: Rust resistant springs secure trim for quick, tool-less installation. 9. Ballast / Cover Assembly: Accessible from below and removable without tools for inspection and ballast replacement . 10.Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors. Allows inspection from below. 11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire. Electrical Electronic Ballast: 120V or 277V, 50/60 Hz.. encased, high power factor, T.H.D.
Ballast ANSI Code Voltage Max. Amps Input Watts 39W MH M130 120/277 0.39/0.17 44 70W MH M98/M143 120/277 0.67/0.28 78
Magnetic Ballast: 120V/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating "B", -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts 39W MH M130 120/277 1.00/0.40 56 70W MH M98/M143 120/277 1.90/0.80 94
Options and Accessories Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory.
Labels: UL (Suitable For Damp Locations), CSA (magnetic ballast only), I.B.E.W.
Job Name:
Cat. No.:
Lamp(s):

Page 2 of 2 6" Aperture, PAR30 Ceramic Metal Halide
(FC) is initial footcandles at center of beam. Beam length (L) and beam width (W) are to where the candlepower is reduced to 50% of the center beam candlepower. (C) is the distance to the center of the beam.
ANGLE WALL 39W PAR30 CERAMIC MH - SPOT 0 393 5 487 10 674 15 1349 20 3847 25 11394 30 21431 35 11215 40 3294 45 951 50 240 55 41 60 8 65 0 70 0 75 0 80 0 85 0 90 0
AIMED 30 deg. TOWARD WALL
30° Aiming Angle Horizontal Surface
30° Aiming Angle Vertical Surface
LAMP: 39W PAR30 SP CERAMIC MH, PHILIPS LUMEN RATING: 2200 LMS.
D C FC L W 6' 3.5' 387 1.5' 1.3' 8' 4.6' 217 2.1' 1.8' 10' 5.8' 139 2.6' 2.2' 12' 6.9' 97 3.1' 2.7' 15' 8.7' 62 3.9' 3.3'
D C FC L W 2' 3.5' 670 1.6' 0.8' 3' 5.2' 298 2.4' 1.2' 4' 6.9' 167 3.2' 1.5' 6' 10.4' 74 4.8' 2.3' 8' 13.9' 42 6.3' 3.1'
ANGLE WALL 70W PAR30 CERAMIC MH - SPOT 0 934 5 1162 10 1615 15 3251 20 9309 25 27611 30 51951 35 27177 40 7969 45 2285 50 561 55 79 60 0 65 0 70 0 75 0 80 0 85 0 90 0
AIMED 30 deg. TOWARD WALL
30° Aiming Angle Horizontal Surface
30° Aiming Angle Vertical Surface
LAMP: 70W PAR30 SP CERAMIC MH PHILLIPS LUMEN RATING: 4850 LMS.
D C FC L W 8' 4.6' 527 2.1' 1.8' 10' 5.8' 337 2.6' 2.2' 12' 6.9' 234 3.1' 2.7' 15' 8.7' 150 3.9' 3.3' 20' 11.5' 84 5.2' 4.4'
D C FC L W 3' 5.2' 722 2.4' 1.2' 4' 6.9' 406 3.2' 1.5' 6' 10.4' 180 4.8' 2.3' 8' 13.9' 101 6.3' 3.1' 12' 20.8' 45 9.5' 4.6'
ANGLE WALL 39W PAR30 CERAMIC MH - FLOOD 0 703 5 765 10 1226 15 2133 20 3040 25 3429 30 3539 35 3485 40 3065 45 2370 50 1477 55 579 60 82 65 11 70 0 75 0 80 0 85 0 90 0
AIMED 30 deg. TOWARD WALL
30° Aiming Angle Horizontal Surface
30° Aiming Angle Vertical Surface
LAMP: 39W PAR30 FL CERAMIC MH, PHILIPS LUMEN RATING: 2200 LMS.
D C FC L W 8' 4.6' 36 7.0' 5.8' 10' 5.8' 23 8.7' 7.3' 12' 6.9' 16 10.4' 8.7' 15' 8.7' 10 13.0' 10.9' 20' 11.5' 6 17.4' 14.6'
D C FC L W 3' 5.2' 49 10.8' 3.8' 4' 6.9' 28 14.4' 5.0' 6' 10.4' 12 21.6' 7.6' 8' 13.9' 7 28.8' 10.1' 12' 20.8' 3 43.1' 15.1'
ANGLE WALL 70W PAR30 CERAMIC MH - FLOOD 0 1545 5 1681 10 2698 15 4696 20 6697 25 7553 30 7797 35 7677 40 6751 45 5219 50 3250 55 1272 60 176 65 18 70 0 75 0 80 0 85 0 90 0
AIMED 30 deg. TOWARD WALL
30° Aiming Angle Horizontal Surface
30° Aiming Angle Vertical Surface
LAMP: 70W PAR30 FL CERAMIC MH, PHILIPS LUMEN RATING: 4850 LMS.
D C FC L W 8' 4.6' 79 7.0' 5.8' 10' 5.8' 51 8.7' 7.3' 12' 6.9' 35 10.4' 8.7' 15' 8.7' 23 13.0' 10.9' 20' 11.5' 13 17.4' 14.6'
D C FC L W 3' 5.2' 108 10.8' 3.8' 4' 6.9' 61 14.4' 5.0' 6' 10.4' 27 21.6' 7.6' 8' 13.9' 15 28.8' 10.1' 12' 20.8' 7 43.1' 15.1'
Job Information Type:
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。