Page 1 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 Lamp TT5




2" max.
2" max.
13/16" (21mm)
23-7/8" (606mm) Square Lens
G G
exposed T-grid ceiling.


Drywall Kit (See Options)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
Drywall Kit, Catalog Number: FK92X2.

Job Information Type:
Job Name:
Expample of pattern mounting
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 Lamp TT5
Model No. FRS2GFW2FTUNVIB (25 watt lamp) LER = FP - 59.1 IW - 59.9 BF - 0.92 Comparative yearly lighting energy cost per
Model No. FRS2GFW2FTUNVIB (40 watt lamp) LER = FP - 55.5 IW - 69.5 BF - 0.92 Comparative yearly lighting energy cost per
1000 lumens = $4.06
1000 lumens = $4.26


0 1421 1421 1421
0 1512 1512 1512
5 1407 1406 1407 134
5 1500 1499 1500 143
2' x 2' fixture with acrylic lens. Ballast: ICN-2TTP40-SC Report is based on 2600 Lumens per lamp. Efficiency: 74.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 1341 1339 1339 378
2' x 2' fixture with acrylic lens. Ballast: ICN-2TTP40-SC Report is based on 3300 Lumens per lamp. Efficiency: 63.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 1434 1432 1433 405
25 1241 1227 1227 566
25 1322 1318 1318 608
35 1084 1078 1074 675
35 1169 1162 1159 728
45 903 897 888 692
45 980 971 963 750
55 697 693 676 616
55 764 756 737 673
65 469 470 444 458
65 523 519 490 507
75 236 244 212 251
75 275 279 242 287
85 68 70 48 79
85 83 85 62 93
90 52 52 31
90 55 56 33
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 1078 20.7 28.0 00-040 1753 33.7 45.5 00-060 3061 58.9 79.5 00-090 3849 74.0 100.0 90-180 0000 0.0 000.0 00-180 3849 74.0 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1155 17.5 27.6 00-040 1883 28.5 44.9 00-060 3306 50.1 78.8 00-090 4194 63.5 100.0 90-180 0000 0.0 000.0 00-180 4194 63.5 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 81 77 74 72 70 68 69 67 66 02 73 67 62 63 59 56 61 57 55 03 67 59 53 56 51 47 54 50 46 04 61 52 46 49 44 40 48 43 39 05 56 47 40 44 39 35 43 38 34 06 52 42 36 40 35 30 38 34 30 07 48 38 32 36 31 27 39 30 27 08 45 35 29 33 28 24 35 28 24 09 42 32 26 31 25 22 32 25 22 10 39 30 24 28 23 20 28 23 20
01 69 66 63 62 60 58 59 58 56 02 63 57 53 54 51 48 52 49 47 03 57 50 45 48 43 40 46 42 39 04 52 45 39 42 38 34 41 37 34 05 48 40 34 38 33 29 37 32 29 06 44 36 30 34 29 26 33 29 26 07 41 33 37 31 26 23 30 26 23 08 38 30 24 28 24 20 28 23 20 09 36 26 22 26 22 18 26 21 18 10 34 25 20 24 20 17 24 20 17
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4104. 4077. 4036. 55 3852. 3830. 3736. 65 3440. 3447. 3256. 75 2693. 2784. 2419. 85 1876. 1931. 1324.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4454. 4413. 4377. 55 4223. 4178. 4073. 65 3836. 3806. 3594. 75 3138. 3184. 2762. 85 2290. 2345. 1711.
S
G
F
W
FT
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 2=2 Lamp
Ballast Type:
FY For NYC Code – I.B.E.W. Manufactured
FN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications (continuned) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 25W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 3447 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%. Lamp Shield: Frost white DR acrylic lens. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.