Page 1 of 2 Direct/Indirect Surface Mounted Fluorescent 2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/08

Page 2 of 2 Direct/Indirect Surface Mounted Fluorescent 2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5
Model No. HDB2SLW128UNVPG LER = FP - 74.7 IW - 33.3 BF - 1.04 Comparative yearly lighting energy cost per
Model No. HDB2SLW228120WA LER = FP - 83.7 IW - 54.1 BF - 0.93 Comparative yearly lighting energy cost per
CANDELA DISTRIBUTION 0
1000 lumens = $3.21
1000 lumens = $2.87


Report Number: G2008221A Catalog Number: HDB2SLW128UNVPG Lamps: (1) F28 T5 Luminaire: HP90 Surface 2' x 4' with linear
Report Number: G2008223A Catalog Number: HDB2SLW228120WA Lamps: (2) F28 T5 Luminaire: HP90 Surface 2' x 4' with linear
0 679 679 679
0 1396 1397 1396
5 675 676 678 64
5 1388 1390 1394 132
15 1325 1347 1368 381
prismatic lens. Ballast: ICN-2S28 Report is based on 2750 Lumens per lamp. Efficiency: 87.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040 Height of Side: 2.280 2.280
15 645 657 668 186
prismatic lens. Ballast: ST232120E (WA) Report is based on 2750 Lumens per lamp. Efficiency: 88.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040 Height of Side: 2.280 2.280
25 1207 1266 1315 583
25 587 619 645 285
35 507 563 607 351
35 1042 1150 1241 718
45 408 495 561 378
45 840 1011 1150 775
55 295 417 505 366
55 608 855 1034 751
65 370 688 892 655
65 179 336 440 320
75 170 517 729 513
75 81 256 370 255
85 18 184 307 187
85 37 363 573 357
90 4 121 225
90 7 222 404
ZONAL LUMEN SUMMARY
COEFFICIENTS OF UTILIZATION –
ZONAL LUMEN SUMMARY
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 535 19.5 22.4 00-040 886 32.2 37.1 00-060 1630 59.3 68.1 00-090 2392 87.0 100.0 90-180 0000 00.0 000.0 00-180 2392 87.0 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1097 19.9 22.5 00-040 1815 33.0 37.3 00-060 3340 60.7 68.7 00-090 4866 88.5 100.0 90-180 0000 0.0 000.0 00-180 4866 88.5 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 92 87 82 81 77 74 77 74 71 02 83 74 67 69 64 59 66 62 58 03 75 64 56 60 54 48 58 52 48 04 68 57 48 53 46 41 51 45 40 05 63 50 42 47 40 35 46 39 34 06 58 45 37 43 36 30 41 35 30 07 53 41 33 39 32 27 37 31 26 08 50 37 29 35 29 24 34 28 24 09 46 34 27 32 26 21 32 25 21 10 43 31 24 30 24 19 29 23 19
01 94 88 83 82 79 75 79 76 73 02 84 76 69 71 65 60 68 63 59 03 76 66 58 61 55 50 59 53 49 04 69 58 49 54 47 42 52 46 41 05 64 51 43 48 41 36 47 40 35 06 59 46 38 44 36 31 42 36 31 07 54 42 33 39 32 27 38 32 27 08 51 38 30 36 29 24 35 29 24 09 47 35 27 33 26 22 32 26 22 10 44 32 25 31 24 20 30 24 20
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 774. 916. 1014. 55 676. 924. 1083. 65 540. 965. 1206. 75 373. 1091. 1466. 85 188. 1614. 2322.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1593. 1871. 2079. 55 1394. 1895. 2218. 65 1116. 1976. 2446. 75 783. 2203. 2889. 85 386. 3183. 4333.
HD
B
S
W
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 1=1 Lamp 2=2 Lamp Ballast Type:
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 2446 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.6%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – Soft white post painted polyester powder.. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder.