Lytecel Recessed Fluorescent LIS6G20LW132

Page 1 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T8, IES RP1 For VDT Areas

  • Features
  • 54.1% efficient (1 lamp) semi-specular louver.
  • 57.6% efficient (1 lamp) specular louver.
  • 1.7 spacing mounting ratio (1 lamp).
  • Semi-specular or specular, low iridescence, pre-anodized aluminum louver.
  • Vertical grain on cross blades eliminates reflected lamp image.
  • Spring loaded latches (self centering).
  • Louver has protective dust guard.
  • Only 5-1/2" deep body.
  • Black housing exterior for cooler ballast operating temperature.
  • UL-Listed twin knockout access plate.
  • Can be mounted in continuous rows.
  • 2 hold-down clips standard.
  • Compatible with Armstrong T ceiling systems.
  • Meets NYC Code requirements.
  • Construction to meet Chicago Plenum Code is available.
  • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Lightolier LIS6G20LW132 — Lytecel Recessed Fluorescent LIS6G20LW132 diagram (page 1)
図 1 · Lytecel Recessed Fluorescent LIS6G20LW132

Mounting Methods Dimensions

Lightolier LIS6G20LW132 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier LIS6G20LW132 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions

G

exposed T-grid ceiling.

T

exposed slot T-grid ceiling.

Lightolier LIS6G20LW132 — T diagram (page 1)
図 4
Lightolier LIS6G20LW132 — T diagram (page 1)
図 5

2" max.

2" max.

Joint of Two Units

Lightolier LIS6G20LW132 — Joint of Two Units diagram (page 1)
図 6 · Joint of Two Units

A/D

Lightolier LIS6G20LW132 — A/D diagram (page 1)
図 7

2" x 2-1/2" Access Plate with (2) 7/8" K.O.s

Lightolier LIS6G20LW132 — A/D diagram (page 1)
図 8

2" max.

Air Return Slots (LIA only)

hold-down clips (1 at each end)

hold-down clips (1 at each end)

48" (1220mm) 39-1/4" (997mm)

Lightolier LIS6G20LW132 — A/D diagram (page 1)
図 9

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

Shown in Armstrong TECH ceiling.

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 2/Folio G07-32 3/07
Show 14 more labels / short text on this page
5-1/2" (139mm) · 15/16" or 9/16" · 9/16" · 6" · 6" · 4-1/4" (108mm) · 48" (1200mm) · 48" (1200mm) · 6" (162mm) · Tegular grid ceiling · 7-3/8" (187mm) · 15/16" or 9/16" · 6" · 1-3/4" (44mm)
Page 2 of the Lightolier LIS6G20LW132 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Lytecel Recessed Fluorescent LIS6G20LW132

Page 2 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T8, IES RP1 For VDT Areas

Model No. LIS6G20LW132120SO LER = FP - 43.4 IW - 39.00 BF - 1.10 Comparative yearly lighting energy cost per

Model No. LIS6G20PW132120SO LER = FP - 45.8 IW - 39.0 BF - 1.10 Comparative yearly lighting energy cost per

1000 lumens = $5.53 Report Number: G1206002 Catalog Number: LIS6G20LW132120SO Lamp: F32 T8 Luminaire: 6" wide Troffer with semi-

CANDELA DISTRIBUTION

1000 lumens = $5.24 Report Number: G1206003 Catalog Number: LIS6G20PW132120SO Lamps: F32 T8 Luminaire: 6" wide Troffer with specular

CANDELA DISTRIBUTION

0.0 45.0 90.0 FLUX

0.0 45.0 90.0 FLUX

0 633 633 633

0 662 662 662

5 630 628 635 60

5 641 643 664 61

specular louver and white reflector. Ballast: Advance REL-2P32-SC Report is based on 2850 Lumens per lamp. Efficiency: 54.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.7 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816

15 590 619 660 175

louver and white reflector. Ballast: Advance REL-2P32-SC Report is based on 2850 Lumens per lamp. Efficiency: 57.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.7 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816

15 630 644 652 181

25 539 599 694 285

25 556 620 712 292

35 473 621 760 388

35 487 678 821 416

45 373 554 581 389

45 398 623 647 430

55 231 260 203 212

55 269 293 208 236

65 12 32 21 28

65 1 29 17 21

75 2 3 5 4

75 0 2 5 3

85 1 1 2 1

85 0 1 2 1

90 0 1 1

90 1 1 1

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

TYPICAL V.C.P.'s

TYPICAL V.C.P.'s

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 91 88 87 82 92 88 86 80 40x40 92 88 87 85 94 88 88 84 60x30 92 88 87 84 93 88 86 81 60x60 92 88 87 85 94 90 88 85 100x100 91 89 88 85 95 92 88 86

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 90 82 82 81 93 88 85 78 40x40 91 82 82 83 94 88 87 82 60x30 91 82 82 83 93 88 86 80 60x60 91 82 83 83 94 90 87 84 100x100 91 82 83 93 95 91 89 85

1 60 58 57 55 54 53 53 52 51 2 56 53 50 50 48 46 48 46 45 3 52 47 44 45 42 40 44 41 39 4 48 43 39 41 37 35 39 37 34 5 44 38 34 37 33 31 36 33 30 6 41 35 30 33 30 27 33 29 27 7 38 32 27 30 27 24 30 26 24 8 36 29 25 28 24 22 27 24 21 9 33 27 22 26 22 19 25 22 19 10 31 24 20 24 20 18 23 20 18

1 64 62 60 59 57 56 56 55 54 2 60 56 53 53 51 49 51 49 47 3 55 50 46 48 45 42 46 44 42 4 51 45 41 43 40 37 42 39 36 5 47 41 36 39 35 32 38 35 32 6 44 37 32 35 31 29 34 31 28 7 41 33 29 33 28 25 31 28 25 8 38 31 26 29 26 23 29 25 23 9 35 28 24 27 23 20 26 23 20 10 33 26 21 25 21 19 24 21 18

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 0520 18.3 33.7 00-040 909 31.9 58.9 00-060 1510 53.0 97.9 00-090 1542 54.1 100.0 90-180 0000 0.0 000.0 00-180 1542 54.1 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 535 18.8 32.6 00-040 950 33.3 57.9 00-060 1617 56.7 98.5 00-090 1641 57.6 100.0 90-180 0000 0.0 000.0 00-180 1641 57.6 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2929. 4350. 4564. 55 2242. 2521. 1969. 65 162. 419. 270. 75 39. 55. 104. 85 33. 69. 103.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3130. 4896. 5087. 55 2605. 2838. 2018. 65 8. 379. 217. 75 10. 53. 98. 85 23. 67. 113.

Ordering Information Explanation of Catalog Number. Example: LIS6G20LW132120SO

W 1

Body StyleA =Air Return S =Static
Ceiling TypeG = 9/16" or
Louver FinishL =Low
Lamp Quantity(By others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
Cells1 row of 20 cells

Length:

15/16"Grid T = Slot Grid A = 9/16" Tegular

Iridescence Semi-specular P=Low

32=T8 (Nominal 48")

no, ie(GLR)

Grid D = 15/16" Tegular

Ballast Type:

Standard Lytecel LI

ReflectorW =White Reflector

For NYC Code – Local 3 Manufactured LN

Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.

Specifications (continued) Finish: Louver—specular or semi-specular low iridescence pre-anodized reflector sheet. Reflector: White baked polyester enamel reflector. Chassis exterior—black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Internal slow-blow fusing. Suffix: GMF. Chicago Plenum: Suffix: CP.

Specifications Performance: In an installation of 1 lamp 32W semi-specular luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .58 with a spacing to mounting ratio of 1.7 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 91 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 2521. Candelas at Nadir (0°) not to exceed 633. Air Handling-(LIA) side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak® or equal).

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 2/Folio G07-32
Show 8 more labels / short text on this page
LI Lytecel 6" · Fixture · Number of · Lamp Fixture · Width · 1=1 Lamp · Iridescence Specular · Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier LIS6G20LW132について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier LIS6G20LW132に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier LIS6G20LW132 取扱説明書(PDF)

2 ページ·173 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…