2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC

Dimensions


Suited to standard exposed T-grid ceilings
Suited to standard exposed Slot T-grid ceilings
Microperforated mesh lamp shield


Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-33
Ceiling compatibility

QVA2GSDOS2FT
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T5 5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
CERTIFIED TEST REPORT NO. LSCA018 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP228120PG SILVER BALL. COVER, WHITE REFLECTOR, PERF. LAMP SHIELD, WHITE OVERLAY TWO 28W T5 FLUORESCENT LAMPS. LUMEN RATING = 2610 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B228PUNV-C
CERTIFIED TEST REPORT NO. LSCA018 COMPUTED BY LSC PROGRAM **TEST-LITE**
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1311 5 1305 1307 1307 1305 1299 126 10 1290 1297 1292 1289 1287 15 1263 1265 1272 1276 1274 358 20 1217 1222 1236 1245 1253 25 1165 1175 1196 1200 1210 548 30 1100 1119 1143 1156 1163 35 1027 1042 1075 1101 1113 671 40 945 963 1004 1051 1055 45 847 877 927 975 992 714 50 742 780 845 901 919 55 635 679 763 821 833 668 60 523 580 663 713 727 65 409 465 562 592 595 522 70 316 370 435 436 423 75 206 259 279 272 269 282 80 119 151 141 158 164 85 38 44 56 57 57 63 90
LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP228120PG SILVER BALL. COVER, WHITE REFLECTOR, PERF. LAMP SHIELD, WHITE OVERLAY TWO 28W T5 FLUORESCENT LAMPS. LUMEN RATING = 2610 LMS. ONE UNIVERSAL TRIAD 120-277V 1 OR 2-LAMP ELECTRONIC BALLAST NO. B228PUNV-C
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 .90 .88 .84 .84 .84 .81 .81 .81 .77 .77 .77 .76
1 .83 .79 .76 .74 .81 .78 .75 .72 .74 .72 .70 .72 .70 .68 .69 .67 .66 .64
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1031 19.77 26.12 0-40 1702 32.62 43.11 0-60 3083 59.08 78.06 0-90 3950 75.68 100.00 40-90 2247 43.06 56.89 60-90 866 16.60 21.94 90-180 0 .00 .00 0-180 3950 75.68 100.00
2 .76 .70 .65 .61 .74 .68 .64 .60 .66 .62 .58 .63 .60 .57 .61 .58 .56 .54
3 .69 .61 .56 .51 .67 .60 .55 .50 .58 .53 .50 .56 .52 .49 .54 .51 .48 .46
4 .63 .55 .48 .43 .62 .54 .48 .43 .52 .46 .42 .50 .45 .42 .48 .44 .41 .40
5 .58 .48 .41 .36 .56 .47 .41 .36 .46 .40 .36 .44 .39 .35 .43 .38 .35 .33
6 .53 .43 .36 .31 .52 .42 .36 .31 .41 .35 .31 .40 .34 .31 .38 .34 .30 .29
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .92 S/MH = 1.3 SC = 1.3
7 .49 .38 .32 .27 .48 .38 .32 .27 .37 .31 .27 .36 .30 .27 .35 .30 .26 .25
8 .45 .34 .28 .23 .44 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 1718 1887 2019 DATE: 55 1587 1915 2091 DEC 5, 2003 65 1387 1911 2027 PREPARED FOR: 75 1142 1545 1498 LIGHTOLIER-CFI 85 627 918 942 CORNWALL, ONTARIO
9 .41 .31 .25 .20 .40 .31 .24 .20 .30 .24 .20 .29 .24 .20 .28 .23 .20 .18
10 .38 .28 .22 .18 .37 .28 .22 .18 .27 .21 .18 .26 .21 .17 .26 .21 .17 .16
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 64.6 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
QHE G 2 3 OP 28
OPTIONS R = Radio Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
VOLTAGE CEILING TYPE Standard exposed T-grid ceilings
HIGH EFFICIENCY Recessed direct indirect soft light high efficiency optical system
LAMP/FIXTURE
FIXTURE
LAMP SHIELD PF = Microperforated
LENGTH (NOMINAL 46'')
BALLAST
28 = 28W T5 54 = 54W T5 HO
PI = Electronic linear T5, IS PG* = Electronic linear T5HO, Pro S * 54W N/A in PI
DETAIL
OP = One piece (no center slot)
SPECIFICATIONS MATERIALS: One piece chassis constructed from die formed 20 gauge cold rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C. LABELS: Listed by CSA, UL
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-33