Audiovoxメーカー128-7760の使用説明書/サービス説明書
ページ先へ移動 of 16
128-7760 1 of 16 1 Model AS 9076 Installation Manual Remote Start Upgrade Module Installation Instructions This Unit Is Intended For Installation In V ehicles With 12 V olt Negative Ground Electrical Systems, Gasoline or Diesel With T rue T ach Reference And Automatic T ransmissions Only .
128-7760 2 of 16 2 This Remote Start/Keyless Entry Upgrade System is designed to be used with Automatic Transmission Vehicles Only! The unit provides a selectable ignition control that allows a 10 second output for glow plug preheat which may be required for certain diesel vehicles, (see selectable feature #5).
128-7760 3 of 16 3 WIRING THE 6 PIN MAIN POWER HARNESS: Note: Do not remove the fuse holders from this wire harness. Fuses must be used and located as close as possible to the power source for adequate protec- tion of the vehicle. Fused RED w/ WHITE TRACE WIRE: + 12 volt Battery 1 Source Locate the vehicle battery wire(s) at the ignition switch.
128-7760 4 of 16 4 SEE NEUTRAL ST ART SAFETY TEST FOR FURTHER DET AILS. BLUE Wire: Ignition 1 Output Connect this wire to the ignition 1 wire from the ignition switch.
128-7760 5 of 16 5 the Black w/ White wire is at open circuit through the control switch, the remote starter is disabled. Connect the Black w/ White tracer wire to one of the wires from the back of the previously mounted control switch. Connect the remaining wire of the control switch to chassis ground.
128-7760 6 of 16 6 This wire should be connected to the ignition input of the alarm system. The Yellow w/ Black wire output will allow you to remote start the vehicle while leaving the alarm armed, and to lock/ unlock the doors while running under control of the remote start unit.
128-7760 7 of 16 7 NOTE: These wires are typically White w/ Black trace and Violet w/ Y ellow trace, however in later model Cadillacs, they are run through an orange sleeve, and are either both Black, both Y ellow , or both White wires. Consult the factory service manual for additional information.
128-7760 8 of 16 8 T achometer Input W iring Det ail WIRING THE 4 PIN AUXILIARY OUTPUT HARNESS The auxiliary 4 pin connector provides low current outputs to control various functions in the vehicle during different stages of the Remote Start unit's operation.
128-7760 9 of 16 9 1. Programmable Features: Feature Lts Flash 1X Lts Flash 2X Lts Flash 3X Lts Flash 4X Default 1 Run Time 5 Min. 10 Min. 15Min. 20 Min. 10 Min 2 Park Lights On Steady Flash Steady 3 Input Check Voltage Tach Tach 4 Voltage Level > 0.
128-7760 10 of 16 10 This Remote Car Starter will learn the tach rate of most vehicles single ignition coils, multiple coil packs, and or single injector. To learn tach; 1. Start with the ignition switch in the "OFF" position and the programming switch in the "ON" position.
128-7760 11 of 16 11 Multi Coil Pack Adaptor: (Optional) The multi coil pack adaptor is designed for use with vehicles having multiple ignition coils where a single point tach signal is unavailable. T o use the adaptor , the Green/Black wires must connect to the negative side of the ignition coil(s).
128-7760 12 of 16 12 TESTING YOUR INST ALLA TION: CAUTION!! The following procedure must be performed after the inst allation of an Audiovox Remote S tart Device. It is the responsibility of the installing technician to complete these tests. Failure to test the unit in the following manner may result in personal injury , property damage, or both.
128-7760 13 of 16 13 this vehicle. The information concerning the Mechanical Neutral Safety Switch provided below will help you to determine if the vehicle you are working on has this type of safety switch and will provide alternate wiring methods to accommodate this situation.
128-7760 14 of 16 14 circuits may be used only if the above circuit is not available. NOTE: When completing an installation using either of the following key in sensor circuits, if the operator inserts the ignition key while the vehicle is running under the control of the Remote S tart, the vehicle will shut down.
128-7760 15 of 16 15 C. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder . D. Cut this wire and connect the ignition cylinder side to the Remote S tart Negative Safety Shut down Wire Gray/Black, using a 4002 series diode as shown above.
128-7760 16 of 16 16 © 2006 Audiovox Electronics Corp., Hauppauge, N.Y . 1 1788 128-7760.
デバイスAudiovox 128-7760の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Audiovox 128-7760をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAudiovox 128-7760の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Audiovox 128-7760の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Audiovox 128-7760で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Audiovox 128-7760を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAudiovox 128-7760の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Audiovox 128-7760に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAudiovox 128-7760デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。