DESCRIPTION The 14 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus- tom-matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-On coils are available for use with upflow, downflow, or horizontal furnaces and air han- dlers.
TECHNICAL GUIDE
SPLIT-SYSTEM AIR CONDITIONERS
5-year limited parts warranty. 10-year limited compressor warranty.
MODELS: H*RE024 THRU 060 (2 THRU 5 NOMINAL TONS)








E
D
T
O
A
R
A I
E
R
T
S
M O
U
R
E
R
A
Y
R
A
R
N O
D
P
Y
A
U
I N
T
T
O
N
G
N
F
U N
A
G
N I
H
T
I W
M
R
E
T R
E
Q
U
P
M
E
N
T
N
S
F O
A R I
F
T S
A
T
A
O
N
N
D
S
A
R
C E
D
T
O
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE
SYSTEM IS LISTED
WITH ARI. LISTED
Due to continuous product improvement, specifications are subject to change without notice.
Certified in accordance with the Unitary Small Equipment cer- tification program, which is based on ARI Standard 210/240.
Visit us on the web at www.york.com for the most up-to-date technical information.
Additional rating information can be found at www.ari.org
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with superscript “B” are Bristol scrolls. All scrolls listed with superscripts “C” are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change with out notice. Certified dimensions will be provided upon request.



- = Not applicable


* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.

6TH07700124 - One Stage Heat / One Stage Cool, non-pro- grammable thermostat, manual changeover with automatic fan on cooling or cooling and heating.
Refer to Price Manual for specific model numbers.
Compressor Blanket - Designed to further reduce the nor- mal operating sound and is required to meet Canadian sound levels for units of three tons and below.
6ET07700324 - One Stage Heat / One Stage Cool, electronic programmable (5 day/2 day) manual changeover.
Refer to Price Manual for specific model numbers.
Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.
TXV KIT - 1TV0700 series must be used to obtain system performance. See Tabular Data Sheet for proper selection.
Room Thermostats - One of the following thermostat may be used with these systems.
* Includes Blanket


MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)
TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.
ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.






N1AHD2006 G2FD061H24 1.02 1.05 1.01
N1VSD20 G2FD061H24 1.02 1.05 0.96
F2FV060 1.07 1.05 1.05
G1HD060 0.98 0.98 0.99
G1NA060S24T 0.99 0.97 0.99
G2FD061H24 1.02 1.05 1.01


N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW)
F2RC / F2FC OR F2RC / F2FP / F2FV FAN COIL UNITS (UPFLOW, HORIZONTAL)


Subject to change without notice. Printed in U.S.A. 036-21315-001 Rev. A (0502) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 550.50-TG1Y (600)