DESCRIPTION The 14 SEER Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be cus- tom-matched with one of UPG’s complete line of evaporator sections, with each serving a specific function. Matching Air Handlers are available for upflow, downflow, or horizontal applications to provide a complete system. Electric Heaters are available, if required. Add-On coils are available for use with upflow, downflow, or horizontal furnaces and air han- dlers.

TECHNICAL GUIDE

WARRANTY

SPLIT-SYSTEM AIR CONDITIONERS

5-year limited parts warranty. 10-year limited compressor warranty.

  • FEATURES
  • QUALITY CONDENSER COILS - The coil is constructed of copper tube and aluminum fins.
  • PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line filter-drier further protects the compressor.
  • DURABLE FINISH - The cabinet is made of pre-painted steel. The pre-treated galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and desert sand matted-textured finish insure less fading when exposed to sunlight.
  • LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof.
  • TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications.
  • LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds.
  • LOW MAINTENANCE - Long life permanently lubricated motor-bearings need no annual servicing.
  • EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls, and the molex plug in the control box connecting the condenser fan make for easy servicing of the unit.
  • SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging.
  • U.L. and C.U.L. listed - approved for outdoor application.

14 SEER

MODELS: H*RE024 THRU 060 (2 THRU 5 NOMINAL TONS)

York H*RE024 — 14 SEER diagram (page 1)
図 1
York H*RE024 — 14 SEER diagram (page 1)
図 2
York H*RE024 — 14 SEER diagram (page 1)
図 3
York H*RE024 — 14 SEER diagram (page 1)
図 4
York H*RE024 — 14 SEER diagram (page 1)
図 5
York H*RE024 — 14 SEER diagram (page 1)
図 6
York H*RE024 — 14 SEER diagram (page 1)
図 7
York H*RE024 — 14 SEER diagram (page 1)
図 8

F

E

D

T

O

A

R

A I

E

R

T

S

M O

U

R

E

R

A

Y

R

A

R

N O

D

P

Y

A

U

I N

T

T

O

N

G

N

F

U N

A

G

N I

H

T

I W

M

R

E

T R

E

Q

U

P

M

E

N

T

N

S

F O

A R I

F

T S

A

T

A

O

N

N

D

S

A

R

C E

D

T

O

CERTIFICATION APPLIES ONLY

WHEN THE COMPLETE

SYSTEM IS LISTED

WITH ARI. LISTED

Due to continuous product improvement, specifications are subject to change without notice.

Certified in accordance with the Unitary Small Equipment cer- tification program, which is based on ARI Standard 210/240.

Visit us on the web at www.york.com for the most up-to-date technical information.

Additional rating information can be found at www.ari.org

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

Page 2 of the York H*RE024 user manual — Physical and Electrical Data
2ページ · クリックして拡大
2ページ

Physical and Electrical Data

MODELH1RE024S06H1RE030S06H1RE036S06H2RE042S06H2RE048S06H2RE060S06 Unit Supply Voltage208 / 230 - 1 – 60 Normal Voltage Range1187 to 252 Minimum Circuit Ampacity12.114.918.117.820.631.8 Max Overcurrent Device Amps2 202025303550 Compressor Type3InertiaInertiaScrollCScrollCScrollCScrollB Rated Lo Compressor Amps Locked Rad 9.310.913.513.215.524.3 otor 57647395109150 Crankcase HeaterNoNoNoNoNoNo Fan Motor Amps Rated Load .51.31.31.31.31.4 Fan Diameter Inches222222242424 Rated HP Fan Motor Nominal Nominal1/151/41/41/41/41/3 RPM 8308258258258251100 CFM 2,2603,3003,3003,3003,3003,500 Face Are Coil Rows De Fin /Incha Sq Ft 19.6523.5823.5822.527.027.0 ep 111222 181818181818 Liquid Line OD3/83/83/83/83/83/8 Vapor Line OD7/87/87/81 1/81 1/81 1/8 Unit Charge (Lbs - Oz)48 - 09 - 149 - 614 - 014 - 315 - 13 Charge Per Foot, oz.0.700.700.700.760.760.76 Operating Weight Lbs209228219240264270

1. Rated in accordance with ARI Standard 110, utilization range “A”. 2. Dual element fuses or HACR circuit breaker. 3. All scrolls listed with superscript “B” are Bristol scrolls. All scrolls listed with superscripts “C” are Copeland scrolls. 4. The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

All dimensions are in inches. They are subject to change with out notice. Certified dimensions will be provided upon request.

York H*RE024 — Physical and Electrical Data diagram (page 2)
図 9 · Physical and Electrical Data
Unit ModelDimensions (Inches)Refrigerant Connection Line Size ABCLiquidVapor 0243337273/87/8 030393727 036393727 0423243321-1/8 048384332 060384332
York H*RE024 — Physical and Electrical Data diagram (page 2)
図 10 · Physical and Electrical Data
1. Included Fan Guard * Reducer Fan Guard
Page 3 of the York H*RE024 user manual — COOLING CAPACITY - With Air Handler Coils
3ページ · クリックして拡大
3ページ

COOLING CAPACITY - With Air Handler Coils

UNIT MODELAIR HANDLERCOIL1 MODELCOOLING MODELELECTRIC 2 HEAT KWWRATED CFMNET MBHSEER W/O TXVSEER + TXV3EER TOTALSENS. 1 PH 14 SEER AC WITH N-AH / G2FD H1RE024S06N1AHB08062,5,8,1017G2FD036S1780025.218.1-14.0012.35 H1RE030S06N1AHB12065,8,10,15,1917G2FD036S17100028.820.7-13.1011.80 H1RE036S06N1AHB12065,8,10,15,1917G2FD036S17120034.024.5-13.3511.80 N1AHB12065,8,10,15,1917G2FD046S17120035.025.6-14.0012.20 N1AHD14065,8,10,1524G2FD048S24120035.425.7-14.0012.50 N1AHD14065,8,10,1524G2FD060S24120036.026.1-14.2012.80 H2RE042S06N1AHC16065,8,10,15,2021G2FD042S21140039.028.2-13.2511.35 N1AHC16065,8,10,15,2021G2FD048S21140039.528.9-13.5011.60 N1AHD14065,8,10,1524G2FD060S24140040.529.6-14.0012.00 H2RE048S06N1AHD20068,10,15,20,25,3024G2FD060S24160046.533.9-13.8511.80 N1AHD20068,10,15,20,25,3024G2FD061H24160047.034.3-14.0011.90 H2RE060S06N1AHD20068,10,15,20,25,3024G2FD060S24190053.537.1-13.5012.00 N1AHD20068,10,15,20,25,3024G2FD061H24205054.539.1-13.5012.10 1 PH 14 SEER AC / N1VS - VARIABLE SPEED H1RE024S06N1VSB1210,15,1817G2FD036S1787025.618.1-15.0013.85 N1VSB1210,15,1817G2FD046S1787026.218.9-15.5014.15 H1RE030S06N1VSB1210,15,1817G2FD036S17100029.420.7-14.5012.95 N1VSB1210,15,1817G2FD046S17107030.021.6-15.3513.60 H1RE036S06N1VSB1210,15,1817G2FD046S17125035.225.6-14.0012.40 N1VSC1610,15,1821G2FD048S21128536.025.7-15.0013.60 H2RE042S06N1VSC1610,15,1821G2FD048S21142040.528.9-14.5012.50 N1VSC1610,15,1821G2FD048S21142040.528.9-14.5012.50 N1VSD2010,15,18,3024G2FD060S24142041.529.6-15.5013.20 H2RE048S06N1VSC1610,15,1821G2FD048S21159046.033.2-14.3012.20 N1VSD2010,15,18,3024G2FD060S24160047.033.9-14.6512.40 H2RE060S06N1VSD208,10,15,20,25,3024G2FD060S24178053.536.3-13.7512.35 N1VSD208,10,15,20,25,3024G2FD061H24178054.537.0-14.0012.60 1 PH 14 SEER AC / F2RP / RC / FP / FC / FV4,5 H1RE024S06F2RP/FP0365,8,10,15,1921-80025.018.0-13.8012.30 F2FP0405,8,10,1521-80025.417.4-14.0012.75 H1RE030S06F2RP/FP0365,8,10,15,1921-100029.821.5-13.8512.40 F2FP0455,8,10,1524-100030.621.5-14.0012.70 H1RE036S06F2RP/FP0365,8,10,15,1921-120034.424.8-13.5012.10 F2RP/FP0425,8,10,1521-120034.424.8-13.3011.90 F2FP0455,8,10,1524-120036.025.5-14.0012.65 H2RE042S06F2FP0455,8,10,1524-140040.529.8-14.0012.00 F2FP0485,8,10,15,20,2524-140039.528.9-13.2511.30 H2RE048S06F2FP0605,8,10,15,20,2524-160046.033.4-13.0011.25 F2FV0608,10,15,20,2524-162547.534.9-15.5013.20 H2RE060S06F2FP06010,15,20,2524--190053.036.7-13.0011.60 F2FV06010,15,20,2524--190053.536.3-13.7512.35 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. 3. TXV = Use 1TV700 Series Kit. 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC . models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.

- = Not applicable

Page 4 of the York H*RE024 user manual — COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils
4ページ · クリックして拡大
4ページ

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils

UNIT MODELFURNACE**COIL MODELCOOLING CFM RANGE (MIN.-MAX.)WRATED CFMNET MBHSEER + TXV W/O TDRSEER + TXV1 + TDR*EER TOTALSENS. H1RE024S06700 90014G1FA036S1480025.018.013.85-12.30 17,21G1FA036S17,2180024.817.913.85-12.20 -G1HD03680025.018.114.00-12.35 17G1NA036S17L80024.016.613.50-12.00 21G1NA048S21D80024.016.613.50-12.00 14G1UA036S1480025.018.013.85-12.30 17,21G1UA036S17,2180024.817.913.85-12.20 17G2FD030S1780024.817.913.85-12.20 14G2FD035S1480024.817.913.85-12.20 17G2FD036S1780025.218.114.00-12.35 21G2FD036S2180025.218.114.00-12.45 H1RE030S06875 112514G1FA036S14100028.420.013.00-11.75 17,21G1FA036S17,21100028.420.013.00-11.65 21,24G1FA048S21,24100030.021.814.00-12.40 -G1HD048100030.021.514.00-12.40 17G1NA036S17L100029.020.0-13.5011.95 24G1NA042S24W100029.020.7-14.0012.00 21G1NA048S21D100029.020.0-13.5011.95 14G1UA036S14100028.420.013.00-11.75 17,21G1UA036S17,21100028.420.013.00-11.65 21,24G1UA048S21,24100030.021.814.00-12.40 17G2FD030S17100028.420.413.00-11.65 17G2FD036S17100028.820.713.10-11.80 21G2FD036S21100028.821.013.10-12.10 21,24G2FD048S21,24100030.221.8-14.0012.50 H1RE036S061050 135021,24G1FA048S21,24120035.225.314.00-12.30 -G1HD048120034.825.013.75-12.30 17G1NA036S17L120033.023.4-13.0011.30 24G1NA042S24W120034.625.0-14.0012.00 21G1NA048S21D120033.023.4-13.0011.30 21,24G1UA048S21,24120035.225.314.00-12.30 17G2FD036S17120034.024.513.35-11.80 21G2FD036S21120034.024.813.35-12.05 21G2FD042S21120034.825.413.70-12.10 17G2FD046S17120035.025.614.00-12.20 21,24G2FD048S21,24120035.225.714.00-12.45 H2RE042S061225 157521,24G1FA048S21,24140039.028.4-13.5011.45 21,24G1FA060S21,24140040.529.6-14.0011.80 -G1HD048140039.028.4-13.2511.50 24G1NA042S24W140040.529.5-14.0011.75 21G1NA048S21D140039.027.3-13.0011.50 21,24G1UA048S21,24140039.028.4-13.5011.45 21,24G1UA060S21,24140040.529.6-14.0011.80 21G2FD042S21140039.028.2-13.2511.35 17G2FD046S17140039.028.6-13.5011.45 21,24G2FD048S21,24140039.528.9-13.5011.60 24G2FD060S24140040.529.6-14.0011.80 H2RE048S061400 180021,24G1FA048S21,24160045.032.6-13.4011.50 21,24G1FA060S21,24160046.533.9-13.8511.80 -G1HD048160045.032.4-13.2511.45 24G1NA042S24W150046.532.8-14.0011.85 21G1NA048S21D140044.029.0-13.0011.50 21,24G1UA048S21,24160045.032.6-13.4011.50 21,24G1UA060S21,24160046.533.9-13.8511.80 21,24G2FD048S21,24160045.533.2-13.5011.60 24G2FD060S24160046.533.9-13.8511.80 24G2FD061H24160047.034.3-14.0011.90
Page 5 of the York H*RE024 user manual — COOLING CAPACITY - With Variable Speed Furnaces
5ページ · クリックして拡大
5ページ

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils (Continued)

UNIT MODELFURNACE**COIL MODELCOOLING CFM RANGE (MIN.-MAX.)WRATED CFMNET MBHSEER + TXV W/O TDRSEER + TXV1 + TDR*EER TOTALSENS. H2RE060S061650 215021,24G1FA060S21,24190053.537.1-13.2512.00 24G2FD060S24190053.537.1-13.2512.00 24G2FD061H24205054.539.1-13.2512.10 -G1HD060190052.536.0-13.0011.75 24G1NA060S24T190053.035.9-13.0011.90 21,24G1UA060S21,24190053.537.1-13.2512.00
1. TXV = Use 1TV700 Series Kit.

* Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up.

COOLING CAPACITY - With Variable Speed Furnaces

UNIT MODELVARIABLE SPEED FURNACE MODELCOIL MODEL1WCOOLING RATED CFMNET MBHSEER W/O TXVSEER + TXV2EER TOTALSENS. 1 PH 14 SEER AC / P1DU / P1XD / P1XU - VARIABLE SPEED3 H1RE024S06P1DUA12VG1FA036S141487025.418.0-15.0013.60 P1DUA12VG1UA036S141487025.418.0-15.0013.60 P1DUA12VG2FD035S141487025.217.9-15.0013.50 P1XDB12VG2FD030S171783026.017.9-15.0013.65 P1XUB12VG1FA036S171787025.418.0-15.5013.75 P1XUB12VG1UA036S171787025.418.0-15.5013.75 P1XUB12VG2FD030S171787025.417.9-15.5013.75 P1XUB12VG2FD036S171787025.818.1-15.5013.90 H1RE030S06P1DUA12VG1FA036S1414100028.820.0-13.5012.50 P1DUA12VG1UA036S1414100028.820.0-13.5012.50 P1DUB16VG2FD036S1717100030.020.7-14.5013.35 P1XDB12VG2FD036S1717104030.220.7-14.0012.50 P1XUB12VG2FD036S1717102029.220.7-14.0012.65 H1RE036S06P1DUB16VG2FD036S1717120034.424.5-14.0012.70 P1DUC20VG1FA048S2121120036.225.3-15.5014.15 P1DUC20VG1UA048S2121120036.225.3-15.5014.15 P1DUC20VG2FD036S2121120034.624.8-14.6513.05 P1DUC20VG2FD048S2121120036.025.7-15.5013.95 P1XDB12VG2FD036S1717113034.824.5-14.2012.60 P1XDD20VG2FD048S2424119536.225.7-14.5013.10 P1XUB12VG2FD036S1717120034.424.5-14.0012.65 H2RE042S06P1DUC20VG1FA048S2121140039.528.4-14.5012.45 P1DUC20VG1FA060S2121140041.029.6-15.0012.80 P1DUC20VG1UA048S2121140039.528.4-14.5012.45 P1DUC20VG1UA060S2121140041.029.6-15.0012.80 P1DUC20VG2FD042S2121140039.528.2-14.0012.30 P1DUC20VG2FD048S2121142040.028.9-14.5012.60 P1DUC20VG2FD048S2121142040.028.9-14.5012.50 P1XDD20VG2FD048S2424136541.028.9-14.4012.50 P1XDD20VG2FD060S2424142041.533.8-14.4012.55 H2RE048S06P1DUC20VG1FA060S2121160546.533.9-14.0012.20 P1DUC20VG1UA060S2121160546.533.9-14.0012.20 P1DUC20VG2FD048S2121160545.533.2-13.5012.00 P1XDD20VG2FD060S2424158047.033.9-13.8012.20 H2RE060S06P1XDD20VG2FD060S2424158052.534.3-13.5012.2 P1DUC20VG1FA060S2121163053.034.9-13.6012.4 P1DUC20VG1UA060S2121163053.034.9-13.6012.4 P1XUC20VG1FA060S2121159053.034.5-13.5012.4 P1XUC20VG1UA060S2121159053.034.5-13.5012.4 P1XUD20VG1FA060S2424156053.034.4-13.7512.5 P1XUD20VG1UA060S2424156053.034.4-13.7512.5 P1XUD20VG2FD060S2424156053.034.4-13.7512.5 P1XUD20VG2FD061H2424156053.534.9-14.0012.8
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. TXV = Use 1TV700 Series Kit. 3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
Page 6 of the York H*RE024 user manual — SOUND RATINGS
6ページ · クリックして拡大
6ページ

COOLING PERFORMANCE

MODELSUCT. T/P @ COMPR.AIR TEMP ON CONDENSERMODELSUCT. T/P @ COMPR.AIR TEMP ON CONDENSER 75×F95×F115×F75×F95×F115×F TEMP.PSIGMBHKWMBHKWMBHKWTEMP.PSIGMBHKWMBHKWMBHKW H1RE024S063561.522.91.4219.41.6315.91.82H2RE042S063561.536.12.3131.72.9427.53.81 4068.525.31.4521.61.6718.01.904068.539.32.3334.62.9530.13.81 4576.028.01.4724.01.7220.11.974576.042.62.3537.72.9732.93.83 5084.030.71.4926.51.7622.32.045084.046.12.3940.93.0035.83.84 H1RE030S063561.526.51.7622.91.9919.22.11H2RE048S063561.543.22.6438.23.3133.24.22 4068.529.41.7725.62.0321.72.194068.547.02.6641.63.3436.44.24 4576.032.51.7728.42.0724.32.274576.050.92.6945.23.3739.74.28 5084.035.81.7631.42.1027.02.335084.054.92.7248.93.3943.04.31 H1RE036S063561.532.01.9629.22.4426.33.10H2RE060S063561.552.43.0946.83.8341.24.82 4068.534.81.9731.92.4528.83.114068.556.83.1151.03.8745.14.86 4576.037.71.9934.72.4731.53.124576.061.43.1555.33.9149.24.91 5084.040.72.0137.62.4834.33.135084.066.23.1859.83.9653.34.96
1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increase capacity 1% for each 2° increase in sub-cooling. b. Decrease capacity 1% for each 2° decrease in sub-cooling. 3. Sub-cooling in excess of 2 0° may result in excessively high condensing temperature with air on condenser above 11 5 °. Maximum recommended condensing temperature is 14 0 °F.

ACCESSORIES

6TH07700124 - One Stage Heat / One Stage Cool, non-pro- grammable thermostat, manual changeover with automatic fan on cooling or cooling and heating.

Refer to Price Manual for specific model numbers.

Compressor Blanket - Designed to further reduce the nor- mal operating sound and is required to meet Canadian sound levels for units of three tons and below.

6ET07700324 - One Stage Heat / One Stage Cool, electronic programmable (5 day/2 day) manual changeover.

SOUND RATINGS

Refer to Price Manual for specific model numbers.

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

UNIT MODELSOUND RATINGS DECIBELS 02476* 03076* 03676 04276 04876 06080

TXV KIT - 1TV0700 series must be used to obtain system performance. See Tabular Data Sheet for proper selection.

Room Thermostats - One of the following thermostat may be used with these systems.

* Includes Blanket

Page 7 of the York H*RE024 user manual — TYPICAL FIELD WIRING
7ページ · クリックして拡大
7ページ

TYPICAL INSTALLATION

York H*RE024 — TYPICAL INSTALLATION diagram (page 7)
図 11

MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE

TYPICAL FIELD WIRING

York H*RE024 — TYPICAL FIELD WIRING diagram (page 7)
図 12

ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES

24 VOLT CONTROL WIRING MINIMUM 18 GA. WIRE (NEC CLASS 2)

TERMINAL W IS ONLY REQUIRED ON SYSTEMS WITH HEAT.

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

Page 8 of the York H*RE024 user manual — TYPICAL INSTALLATION
8ページ · クリックして拡大
8ページ
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO.H1RE024S06 INDOOR COIL MODEL NO.F2RP/F2FP036 CONDENSER ENTERING AIR TEMPERATUREID CFM110012501350 ID DB858075708580757085807570 ID WB726762577267625772676257 75T.C.30.227.825.423.330.628.225.823.930.728.326.124.3 S.C.17.717.817.917.919.119.019.218.919.819.719.819.1 K.W1.751.741.721.701.811.791.781.771.831.821.811.79 85T.C.28.526.223.922.128.826.524.322.628.926.624.522.9 S.C.17.317.317.417.418.518.518.617.819.319.219.218.1 K.W1.871.851.821.801.931.911.891.871.961.941.921.90 95T.C.26.924.822.620.927.225.023.021.527.325.223.421.7 S.C.16.916.817.016.518.118.018.016.918.818.818.417.1 K.W2.021.991.961.932.082.052.022.002.112.082.062.03 105T.C.25.323.221.319.825.623.621.820.225.623.722.120.4 S.C.16.416.316.415.617.617.517.215.918.418.217.416.1 K.W2.182.142.102.072.252.212.172.142.282.242.212.17 115T.C.23.621.720.018.623.822.020.518.924.022.320.719.1 S.C.15.915.815.814.617.116.916.114.917.917.616.315.1 K.W2.362.312.262.212.422.372.332.292.462.412.372.32 125T.C.21.920.218.717.422.020.419.217.622.420.919.317.8 S.C.15.415.315.213.616.616.315.013.917.417.015.214.1 K.W2.542.482.422.352.592.532.492.442.642.582.532.47 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air HandlerCoilT.C.S.C.KW N1AHB0806G2FD036S171.011.011.00 N1VSB12G2FD036S171.021.010.91 N1VSB12G2FD046S171.051.050.91 F2FP0401.020.970.98 F2RP/F2FP0361.001.001.00 G1FA036S141.001.001.00 G1FA036S17,210.990.991.00 GFD030S170.990.991.00 GFD035S140.990.991.00 G1UA036S17,210.990.991.00 G2FD036S171.011.011.00 G2FD036S211.011.011.00 G1HD036S1.001.010.98 G1NA036S17L0.960.920.98 G1NA048S21D0.960.920.99 G1UA036S141.001.001.00
Variable Speed FurnaceCoilT.C.S.C.KW P1DUA12VG1FA036S141.021.000.92 P1DUA12VG1UA036S141.021.000.92 P1DUA12VG2FD035S141.010.990.92 P1XDB12VG2FD030S171.040.990.94 P1XUB12VG1FA036S171.021.000.91 P1XUB12VG1UA036S171.021.000.91 P1XUB12VG2FD030S171.020.990.91 P1XUB12VG2FD036S171.031.010.91
Page 9 of the York H*RE024 user manual — TYPICAL INSTALLATION
9ページ · クリックして拡大
9ページ
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO.H1RE030S06 INDOOR COIL MODEL NO.G1UA048S21, 24 CONDENSER ENTERING AIR TEMPERATUREID CFM80010001200 ID DB858075708580757085807570 ID WB726762577267625772676257 75T.C.35.932.830.227.036.633.530.927.736.933.831.428.1 S.C.21.221.220.421.422.822.922.023.123.923.923.124.2 K.W1.681.701.711.701.681.691.701.701.671.691.701.70 85T.C.34.131.128.625.634.731.729.326.235.032.029.626.6 S.C.20.620.619.720.822.222.221.422.423.323.322.423.6 K.W1.891.891.891.861.891.891.891.871.891.891.891.87 95T.C.32.329.527.124.232.830.027.724.833.130.428.025.2 S.C.20.020.019.220.121.621.620.821.722.722.721.722.8 K.W2.072.052.031.992.072.062.042.002.072.062.052.01 105T.C.30.527.825.622.730.928.326.123.431.128.626.323.9 S.C.19.419.418.619.421.021.020.121.122.122.121.122.0 K.W2.232.192.162.102.232.202.172.122.242.212.182.13 115T.C.28.626.024.021.229.026.524.422.129.326.824.722.5 S.C.18.818.717.918.720.420.419.420.321.521.420.520.8 K.W2.372.322.272.202.382.332.282.232.382.342.292.24 125T.C.26.724.222.319.727.124.722.620.827.525.023.021.1 S.C.18.218.017.218.019.819.818.819.520.920.719.919.6 K.W2.512.452.382.302.532.462.392.342.522.472.402.35 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air HandlerCoilT.C.S.C.KW N1AHB1206G2FD036S170.960.951.01 N1VSB12G2FD036S170.980.950.94 N1VSB12G2FD046S171.000.990.91 F2FP0451.020.991.00 F2RP/F2FP0360.990.990.99 G1UA036S140.950.921.00 G1UA048S21,241.001.001.00 GUA036S17,210.950.921.01 GFA036S17,210.950.921.01 GFD030S170.950.941.01 G1UA048S21,241.001.001.00 G2FD036S170.960.951.01 G2FD036S210.960.960.98 GFD048S21,241.011.011.00 G1HD048S1.000.991.00 G1NA036S17L0.970.921.00 G1NA042S24W0.970.951.00 G1NA048S21D0.970.921.00 G1UA036S140.950.921.00
Variable Speed FurnaceCoilT.C.S.C.KW P1DUA12VG1FA036S140.960.920.95 P1DUA12VG1UA036S140.960.920.95 P1DUB16VG2FD036S171.000.950.93 P1XDB12VG2FD036S171.010.951.00 P1XUB12VG2FD036S170.970.950.95
Page 10 of the York H*RE024 user manual — TYPICAL INSTALLATION
10ページ · クリックして拡大
10ページ
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO.H1RE036S06 INDOOR COIL MODEL NO.G1UA048S21, 24 CONDENSER ENTERING AIR TEMPERATUREID CFM100012001400 ID DB858070858070858070 ID WB726757726757726757 75T.C.40.036.934.341.338.135.742.038.936.7 S.C.25.424.423.427.626.325.529.627.927.2 K.W1.981.961.941.991.971.952.001.981.96 85T.C.38.635.632.739.636.634.040.237.334.9 S.C.24.823.822.827.025.824.929.127.626.6 K.W2.212.182.172.222.192.182.232.202.19 95T.C.37.234.231.037.835.232.438.435.833.0 S.C.24.223.322.326.425.324.228.527.225.9 K.W2.442.412.402.452.422.412.462.422.42 105T.C.35.532.329.636.133.130.636.733.731.2 S.C.23.522.621.725.624.623.527.626.525.3 K.W2.752.722.722.752.732.722.762.732.73 115T.C.33.730.428.134.431.128.735.031.729.4 S.C.22.821.821.124.723.922.826.825.824.6 K.W3.063.043.033.063.043.023.073.043.03 125T.C.31.928.526.732.729.126.933.329.727.6 S.C.22.221.120.523.923.122.125.925.124.0 K.W3.373.363.343.373.353.323.383.353.33 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air HandlerCoilT.C.S.C.KW N1AHB1206G2FD036S170.970.971.01 N1AHB1206G2FD046S170.991.011.00 N1VSB12G2FD046S171.001.010.99 N1VSC16G2FD048S211.021.020.92 N1AHD14G2FD048S241.011.020.99 N1AHD14G2FD060S241.021.030.98 F2FP0451.021.010.99 F2RP/F2FP0420.980.981.01 F2RP/F2FP0360.980.980.99 G1FA048S21,241.001.001.00 GFD042S210.991.001.00 G2FD036S170.970.971.01 G2FD036S210.970.980.99 G2FD046S170.991.011.00 G2FD048S21,241.001.020.99 G1HD048S0.990.990.99 G1NA036S17L0.940.921.02 G1NA042S24W0.980.991.01 GNA048S21D0.940.921.02 G1UA048S21,241.001.001.00
Variable Speed FurnaceCoilT.C.S.C.KW P1DUB16VG2FD036S170.980.970.95 P1DUC20VG1FA048S211.031.000.89 P1DUC20VG1UA048S211.031.000.89 P1DUC20VG2FD036S210.980.980.93 P1DUC20VG2FD048S211.021.020.90 P1XDB12VG2FD036S170.990.970.97 P1XDD20VG2FD048S241.031.020.97 P1XUB12VG2FD036S170.980.970.95
Page 11 of the York H*RE024 user manual — TYPICAL INSTALLATION
11ページ · クリックして拡大
11ページ
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO.H2RE042S06 INDOOR COIL MODEL NO.G1UA060S21,24 CONDENSER ENTERING AIR TEMPERATUREID CFM130014501550 ID DB858075708580757085807570 ID WB726762577267625772676257 75T.C.47.343.840.337.247.744.340.937.748.044.541.238.0 S.C.28.328.528.929.229.830.030.630.730.831.031.631.7 K.W2.882.842.802.772.952.902.872.843.002.952.912.88 85T.C.44.641.338.135.145.041.838.635.545.242.138.835.9 S.C.27.427.628.128.229.029.229.629.830.030.230.630.8 K.W3.143.103.063.043.203.163.133.113.253.213.173.15 95T.C.42.239.036.033.142.539.536.433.742.839.736.633.9 S.C.26.626.827.227.428.228.428.728.929.329.429.729.8 K.W3.453.413.393.373.523.483.453.433.563.523.493.47 105T.C.39.736.833.931.240.137.234.231.840.337.334.432.2 S.C.25.926.126.426.627.527.627.928.228.528.528.928.6 K.W3.823.793.773.753.893.863.833.813.933.903.873.85 115T.C.37.234.531.729.337.634.832.130.037.835.032.330.3 S.C.25.125.225.525.626.726.727.126.627.727.727.926.9 K.W4.264.234.214.194.324.294.274.264.364.344.314.30 125T.C.34.732.229.527.435.132.430.028.235.332.730.228.4 S.C.24.324.324.624.625.925.826.325.026.926.926.925.2 K.W4.704.674.654.634.754.724.714.714.794.784.754.75 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air HandlerCoilT.C.S.C.KW N1AHC1606G2FD042S210.960.951.00 N1AHC1606G2FD048S210.980.980.99 N1AHD1406G2FD060S241.001.000.98 N1VSC16G2FD048S211.000.980.94 N1VSD20G2FD060S241.021.000.92 F2FP0451.001.010.98 F2FP0480.980.981.02 G1NA042S24W1.001.001.00 GNA048S21D0.960.920.99 G1FA048S21,240.960.960.99 G1FA060S21,241.001.001.00 G1UA048S21,240.960.960.99 G1UA060S21,241.001.001.00 G2FD042S210.960.950.99 G2FD046S170.960.970.99 G2FD048S21,240.980.980.98 G2FD060S241.001.001.00 GHD048S0.960.960.99
Variable Speed FurnaceCoilT.C.S.C.KW P1DUC20VG1FA048S210.980.960.92 P1DUC20VG1FA060S211.011.000.93 P1DUC20VG1UA048S210.980.960.92 P1DUC20VG1UA060S211.011.000.93 P1DUC20VG2FD042S210.980.950.94 P1DUC20VG2FD048S210.990.980.92 P1DUC20VG2FD048S210.990.980.93 P1XDD20VG2FD048S241.010.980.96 P1XDD20VG2FD060S241.161.001.12
Page 12 of the York H*RE024 user manual — TYPICAL INSTALLATION
12ページ · クリックして拡大
12ページ
COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO.H2RE048S06 INDOOR COIL MODEL NO.G2FD060S24, G1UA060S21,24 CONDENSER ENTERING AIR TEMPERATUREID CFM140016001800 ID DB858070858070858070 ID WB726757726757726757 75T.C.53.349.545.554.350.246.455.251.047.3 S.C.33.432.631.135.935.033.038.337.434.9 K.W2.762.722.692.772.742.702.772.762.70 85T.C.51.247.743.952.048.444.852.849.145.7 S.C.33.132.130.635.434.532.637.736.834.6 K.W3.073.043.013.073.053.023.083.063.03 95T.C.49.045.942.449.746.543.250.347.244.1 S.C.32.731.630.034.933.932.237.136.234.4 K.W3.373.353.333.383.363.343.383.373.35 105T.C.46.643.540.147.344.140.848.044.741.6 S.C.31.730.729.034.032.931.236.335.133.3 K.W3.783.753.743.793.763.753.793.773.75 115T.C.44.141.137.844.941.638.445.642.239.1 S.C.30.829.828.133.131.930.235.434.132.3 K.W4.184.164.154.194.164.154.214.164.15 125T.C.41.738.735.542.539.236.043.339.736.6 S.C.29.828.827.132.231.029.234.633.131.3 K.W4.594.564.564.604.564.554.624.564.55 NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air HandlerCoilT.C.S.C.KW N1AHD2006G2FD060S240.990.991.00 N1AHD2006G2FD061H241.001.001.00 N1VSC16G2FD048S210.980.970.95 N1VSD20G2FD060S241.000.990.96 F2FP0600.980.971.04 F2FV0601.011.020.91 G1NF060SOF0.990.960.99 G1UA048S21,240.960.950.99 G1UA060S21,240.990.991.00 G2FD048S21,240.970.970.99 G2FD060S240.990.991.00 G2FD061H241.001.001.00 G1FA048S21,240.960.950.99 G1FA060S21,240.990.991.00 G1HD048S0.960.941.00 G1NA042S24W0.990.960.99 GNA048S21D0.940.850.97
Variable Speed FurnaceCoilT.C.S.C.KW P1DUC20VG1FA060S210.990.990.97 P1DUC20VG1UA060S210.990.990.97 P1DUC20VG2FD048S210.970.970.96 P1XDD20VG2FD060S241.000.990.98
Page 13 of the York H*RE024 user manual — INDOOR COIL MODEL NO. G2FD060S24; G1UA060S21, 24
13ページ · クリックして拡大
13ページ

INDOOR COIL MODEL NO. G2FD060S24; G1UA060S21, 24

N1AHD2006 G2FD061H24 1.02 1.05 1.01

N1VSD20 G2FD061H24 1.02 1.05 0.96

F2FV060 1.07 1.05 1.05

G1HD060 0.98 0.98 0.99

G1NA060S24T 0.99 0.97 0.99

G2FD061H24 1.02 1.05 1.01

Page 14 of the York H*RE024 user manual — MATCHING INDOOR COMPONENTS
14ページ · クリックして拡大
14ページ

MATCHING INDOOR COMPONENTS

York H*RE024 — MATCHING INDOOR COMPONENTS diagram (page 14)
図 13

N1AH OR N1VS MODULAR BLOWER (UPFLOW, HORIZONTAL AND DOWNFLOW)

F2RC / F2FC OR F2RC / F2FP / F2FV FAN COIL UNITS (UPFLOW, HORIZONTAL)

Page 15 of the York H*RE024 user manual — NOTES
15ページ · クリックして拡大
15ページ

NOTES

Page 16 of the York H*RE024 user manual — Unitary 5005 Norman Product York OK Group Drive 73069
16ページ · クリックして拡大
16ページ

Subject to change without notice. Printed in U.S.A. 036-21315-001 Rev. A (0502) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 550.50-TG1Y (600)

Unitary 5005 Norman Product York OK Group Drive 73069

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

York H*RE024について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
York H*RE024に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

York H*RE024 取扱説明書(PDF)

16 ページ·573 KB·エアコン·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…