GARDENA Clear Water Submersible Pump 11000CLEAR Art. 9034 / 17000CLEAR Art. 9036 / Dirty Water Submersible Pump 20000DIRT Art. 9044

1. SAFETY 13 2. ASSEMBLY 14 3. OPERATION 15 4. MAINTENANCE 17 5. STORAGE 17 6. TROUBLESHOOTING 18 7. TECHNICAL DATA 19 8. ACCESSORIES 19 9. SERVICE / WARRANTY 20

Intended use: The GARDENA Submersible Pump is intended for drain- age purposes if flooding occurs but also for transferring water to and from tanks and pumping them out, for draw- ing water from wells and shafts, for draining boats and yachts and for aerating and circulating water for limited periods and for pumping water containing chlorine and detergents in private domestic gardens and allotments.

Liquids to be pumped: The GARDENA Submersible Pump must only be used to pump water. The pump is fully submersible (water-tight encapsulation) and is submerged in water (for max. submersion depth, see 7. TECHNICAL DATA).

Translation of the original instructions.

This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user mainte- nance must not be performed by children without supervision. The use of this prod- uct by young people under the age of 16 is not recommended.

  • The product is suitable for pumping the following liquids:
  • Clear Water Submersible Pump: clean to slightly dirty water with a max. particle size of 5 mm.
  • Dirty Water Submersible Pump: dirty water with a max. particle size of 35 mm. The product is not intended for long term use (continuous circulation operation).

1. SAFETY

v Contact GARDENA Service if the residual current

device (RCD) has triggered.

Symbols on the product:

you maintain or replace parts. Thereby the dis- connected socket must be in the visual range.

Read operator’s manual.

Safe operating practices The water temperature should not exceed 35 °C. The pump must not be used when people are in the water. Pollution of the liquid could occur due to leakage of lubricants. Keep bystanders away from the water. Operate the pump only with the elbow connector.

General safety warnings Electrical safety

current device (RCD) having a rated residual operating current not exceeding 30 mA.

Page 2 of the Gardena Clear Water Pump 11000 Aquasensor user manual — 2. ASSEMBLY
2ページ · クリックして拡大
2ページ

The hose end should be lower than the maximum delivery head.

Mains plug and extension connections must be protected from water splashes. Ensure that the electrical connections for plugs and sockets are made in areas safe from flooding. Protect the mains plug and the mains power cable from heat, oil and sharp edges. Observe the mains voltage. The information on the name- plate must be in agreement with the data for the mains power grid. The pump’s mains plug must be disconnected before anybody enters the swimming pool or touching the sur- face of the water. The mains power cable must not be used for fastening or transporting the pump. For submerging or lifting / securing the pump, please use a fastening rope. Please regularly check the connecting line. Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection. A pump which is damaged should not be used. In the event of damage, have the pump checked by the GARDENA Service. Assembly instructions: Retighten all screws by hand. Before use after maintenance, make sure that all parts are screwed together. When using our pumps with a generator, the warnings of the generator manufacturer must be observed.

Circuit breakers Thermal protection switch: In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cooling of the motor, the pump is operational again.

Automatic venting This pump is equipped with a vent valve which eliminates any air pockets in the pump. Depending on the function, a small amount of water can escape from the side of the housing.

Additional safety warnings Electrical safety

Cables If extension cables are used, these must comply with the minimum cross-sections in the table below:

Voltage Cable length Cross section

DANGER! Risk of suffocation! Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers. Keep toddlers away when you assemble the product. Observe the minimum water level in accordance with the characteristics given for the pump. Allow the pump to run no longer than 10 minutes against a closed pressure side. Sand and other abrasive substances cause increased wear and reduce the pump’s output. The sensor fields may may only be operated outside the water. The hose must not be disconnected during operation. Allow the pump to cool down before troubleshooting.

230. 240 V / 50 Hz Up to 20 m 1.5 mm 2
230. 240 V / 50 Hz 20 – 50 m 2.5 mm 2

wall). v Don’t use the power cable for plugging off. v If the supply cord is damaged, it must be replaced by

the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

2. ASSEMBLY

Connection possibilities of the connection nipple [ Fig. A1 ]: The hose can be connected via the connection nipple 4 with different hose diameters or the GARDENA Connection System.

you assemble the product.

Personal safety

Page 3 of the Gardena Clear Water Pump 11000 Aquasensor user manual — 3. OPERATION
3ページ · クリックして拡大
3ページ

Large hose diameter Cut off nipple at < [ Fig. A2 ]

19 mm (3/4") / 15 mm (5/8") and 13 mm (1/2") hoses can be connected via the GARDENA Connection System. We do not recommend hose diameters smaller than 25 mm (1"), otherwise there will be a significant reduction in the output of the delivery rate.

GARDENA Connection System / Art. 9036 / 9044: Medium hose diameter

Cut off nipple at y [ Fig. A3 ]

Hose diameter Pump connection

Small hose diameter Do not cut off nipple [ Fig. A4 ]

13 mm (1/2") GARDENA Pump Connection Set Art. 1750

When using the largest hose diameter, the pump has the maximum delivery capacity.

15 mm (5/8") GARDENA Pump Connection Set Art. 1750

19 mm (3/4") GARDENA Pump Connection Set Art. 1752

Pump Art. 9034 Art. 9036 Art. 9044

1. Cut off the connection nipple 4 at y . 2. Connect the hose to the connection nipple 4 via the appropriate GARDENA Connection System.

Small hose diameter Art. GARDENA Hose Clamp

32 mm (1 1/4")

Art. 7193

Art. 7194

Medium hose diameter Art. GARDENA Hose Clamp

GARDENA Connection System G 1"

38 mm (1 1/2")

To assemble the pump connection [ Fig. A5 ]:

32 mm (1 1/4") * Art. 7194

Art. 7195

Large hose diameter Art. GARDENA Hose Clamp

38 mm (1 1/2")

nector.

The hose can be easily connected and disconnected using the locking devices 2 on the elbow connector 1. With Art. 9034 / 9036 a non-return valve is supplied which prevents water from flowing back through the hose. The max. delivery rate is only achieved without the non-return valve. If only a small amount of reflux is expected, e. g. if the hose is laid flat, we recommend dispensing with the valve due to the better delivery and suction performance. 1. Only for Art. 9034 / 9036: Insert the non-return valve ß V into the pump. Observe the installation direction. 2. Screw the elbow connector 1 clockwise into the pump until it stops. (If the hose is to be installed horizontally, the elbow connector 1 can be screwed out again up to half a turn. When using the non-return valve, increased force is required.) 3. Screw the connection piece 3 into the connection nipple 4. 4. Push the connection nipple 4 of the hose into the elbow connector 1 until it stops until it engages audibly and visibly. The hose is securely connected to the pump.

Art. 7195

Art. 7196

When using the 38 mm (1 1/2") hose, we recommend the GARDENA Flat Hose Set Art. 5005 with 10 m hose and hose clamp. * For Art. 9034 an additional connection nipple ß 4a for 1 1/4" hoses is supplied.

To connect the hose via the connection nipple: 1. When using the large diameter hose, cut off the con- nection nipple 4 at

Connect hose via the GARDENA Connection System: With 17000CLEAR / 20000DIRT (Art. 9036 /˘9044) the hose cannot be connected via the connection nipple 4 with the GARDENA Connection System.

3. OPERATION

Take care that the pump is located where the inlet open- ings at the suction base are not obstructed neither com- pletely nor partly. Stand the pump on a brick if using in a pond. If the suction process is close to the minimum water level at start-up, the suction process may take longer. 1. Immerse the pump. 2. Connect the pump to the mains. Attention! The pump begins operating immediately. The sensor is initialised and indicated by a running light.

you connect, adjust or transport the product.

To pump water: If the pump cannot be immersed via the handle, the pump must always be immersed via a rope. Attach the rope by pulling it through the eyelets provided and knotting it. Minimum immersion depth during initial operation see 7. TECHNICAL DATA.

25 mm (1") · 51 mm (2")

Page 4 of the Gardena Clear Water Pump 11000 Aquasensor user manual — Large hose diameter Cut off nipple at < [ Fig. A2 ]
4ページ · クリックして拡大
4ページ

Automatic operation [ Fig. O1 ]: In automatic operation the pump switches on automatically when the water level reaches the switch-on level and switches off automatically when the water level reaches the switch-off level.

If the sensor field ß S1 is activated several times within a short time by water flowing back from the hose line, there is a pause of 10 minutes. If the water level reaches sensor field ß S2 , the pump switch- es on automatically, even within the pause of 10 minutes. If this is the case regularly, please select the next sensor field as the switch-on point. In order to ensure quick suction, the pump switches off briefly for the sensor field ß S1 – sensor field ß S5 to vent. After 20 seconds of operation, the pump switches off once for approx. 2 seconds and then on again.

Switch-on / switch-off heights of the sensor fields: The sensor has nine sensor fields (ß S1 to ß S9 from bottom to top), which are located to the right of the LEDs. The sensor fields are about 1 cm high (no finger or changed water level is detected between the sensor fields).

Sensor field ß S1 ß S2 ß S3 ß S4 ß S5 ß S6 ß S7 ß S8 ß S9

To display switch-on and switch-off heights: v Keep the sensor field ß S6 pushed until the double flash- ing of all LED's has acknowledged the input. The currently set switch-on and switch-off heights are displayed.

Art. 9034 / 9036 Switch height [mm]

5 19 34 53 77 105 136 170 207

Art. 9044 Switch height [mm]

42 54 69 88 112 140 171 205 242

Disable the water level tracking: In automatic operation, the LEDs follow the water level. This can be deactivated. v Keep the sensor field ß S8 pushed during initialisation until the double flashing of all LED's has acknowledged the input (see To pump water). To switch the water level tracking back on, push and hold the sensor field ß S8 again during initialisation until the double flashing of all LED's has acknowledged the input.

Art. 9034 / 9036: When the feet are folded in, the values are 4 mm higher in each case.

After plugging in the pump the 9 LED’s light up one after the other. The pump starts at the factory in automatic mode with sensor field switch-on height ß S8 and sensor field switch-off height ß S4 .

Demo mode: For presentation purposes, the pump can be put into demo mode. In this mode, the LEDs simulate the pump’s functions via flashing sequences and the sensor fields react to touch. v Keep the sensor fields ß S5 and ß S8 pushed during initiali- sation when switching on or during the self-test after plugging in until the double flashing of all LED’s has acknowledged the input. To switch off the demo mode again, push and hold the sensor fields ß S5 and ß S8 during initialisation when switching on or during the self-test after plugging in until the double flashing of all LED's has acknowledged the input.

To adjust the switch-on / switch-off heights [ Fig. O1 ]: The sensor fields can only be adjusted outside the water. When the pump has been removed from the water, the sensor should be dried for programming. The upper sensor field is always the switch-on height, the lower sensor field is always the switch-off height. 1. Operate the sensor field until the input is acknowledged with a short double flash of all LEDs. 2. Keep the sensor field ß S7 pushed until the double flash- ing of all LED's has acknowledged the input. The currently set switch-on and switch-off heights are briefly displayed. After that all sensor fields light up. 3. Push the desired upper sensor field for the switch-on height. The LED of the selected sensor field switches off. 4. Push the desired lower sensor field for the switch-off height. The LED of the selected sensor field switches off. After 3 seconds, the set switch-on and switch-off heights are accepted and displayed.

Manual operation [ Fig. O1 ]: In manual mode the pump runs until the pump is discon- nected from the mains. This mode is particularly suitable for flat suction. In manual operation the sensor fields are deactivated. The pump then runs until the pump is disconnected from the mains or another operating mode is selected. v Keep the sensor fields ß S6 and ß S8 pushed until the double flashing of all LED’s has acknowledged the input. All LEDs will light up and within 5 seconds all the LEDs will switch off one after the other. The pump starts. During these 5 seconds the pump should be placed in the water. A start will only take place if the pump detects water. If this is not the case, the countdown is repeated up to three times. If you need more time to put the pump into the water, please disconnect the pump from the power supply. The countdown will continue after the sensor is plugged in again.

Automatic clear water suction for very low water levels: Sensor field ß S1 can be selected both as switch-on and switch-off point. If the sensor field ß S1 still detects water within 10 minutes after starting the pump, the pump switches off to prevent damage due to dry running. The pump will still start if sensor field ß S2 detects water. In this case, however, the sensor should be cleaned to ensure exact water level detection.

Page 5 of the Gardena Clear Water Pump 11000 Aquasensor user manual — 5. STORAGE
5ページ · クリックして拡大
5ページ

The manual operation remains active even after discon- necting the power supply. To stop manual operation, disconnect the pump from the mains and take it out of the water. Connect the pump to the power supply again and keep sensor field ß S9 pressed until it is acknowledged by double flashing of all LEDs. Now you are again in automatic mode. Only operate the manual mode under supervision.

After disconnecting the power supply, the pump auto- matically switches back to automatic operation. To return to the automatic mode again, push and hold the 2 sensor fields ß S7 and ß S8 simultaneously until the double flashing of all LEDs has acknowledged the input.

Flat suction / normal operation (only for the clear water submersible pumps) [ Fig. O2 ]: Normal operation: Recommended operating mode for maximum pumping capacity and grain size up to 5 mm, especially in automatic mode. v Fold the 3 folding feet ; inwards.

Time-limited manual operation: In time-limited manual operation, the sensor fields are deactivated for 10 minutes. The pump then runs for 10 minutes and then switches off automatically. v Keep the sensor fields ß S7 and ß S8 pushed until the double flashing of all LED’s has acknowledged the input. All LEDs will light up and within 10 seconds all LEDs will switch off one after the other. The pump starts. After 10 minutes the pump automatically switches back to automatic operation.

Flat suction: The residual water height of approx. 1 mm is only achieved with flat suction in manual operation. Please note that in this mode the delivery and suction capacity is reduced. v Fold the 3 folding feet ; outwards.

4. MAINTENANCE

v Clean the surface of the pump with a damp cloth.

To flush the pump: After pumping water containing chlorine, detergents or heavily soiled water, the pump must be flushed. 1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning agent (e. g. detergent) until the pumped water runs clear. 2. Remove residuals according to the waste disposal laws applicable in your area.

you maintain the product.

To clean the pump:

(in particular high-pressure water jet). v Do not clean with chemicals including petrol or

solvents. Some can destroy critical plastic parts.

5. STORAGE

To put into storage: The pump is not frost-proof! The product must be stored away from children.

Disposal(in accordance with RL2012/19/EC)

The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.

1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs out.
3. Clean the pump (see 4. MAINTENANCE).

recycling collection centre.

4. Store the pump in a dry, enclosed and frost-free place.
Page 6 of the Gardena Clear Water Pump 11000 Aquasensor user manual — Pump does not start with activated sensor field ß S1
6ページ · クリックして拡大
6ページ

6. TROUBLESHOOTING

3. Pull the suction base 7 off the pump. 4. Clean suction base 7 and impeller 8 (the warranty does not become void as a result of this maintenance work). 5. Clean the sealing surfaces carefully to avoid damage and leakage. 6. Reassemble the suction base 7 in reverse order. A damaged seal must be replaced. For safety reasons a damaged impeller can only be exchanged by the GARDENA Service Centre.

you troubleshoot the product.

To clean the suction base and the impeller [ Fig. T1 ]: 1. Only for Art. 9044: Unscrew the 5 Phillips screws 9 and remove the cover 0. 2. Unscrew the 4 Phillips screws 6.

Problem Possible Cause Remedy

Pump is running, but doesn’t deliver water

Low water level and filled hose with built-in non return valve.

v Remove the check valve or empty

Air cannot escape, because the pressure line is closed. (Possible kink in the pressure hose.)

v Open the pressure line

(e. g. shut-off valve, delivery units).

Air in suction foot. v Wait for about 60 seconds until

the pump has vented; if necessary, turn off and then on again.

Error code 2 Suction opening is clogged. v Clean the suction opening with

a water jet.

Hose is clogged. v Remove the clog from the hose.

Error code 1 Impeller is blocked. v Clean the impeller.

Error code 2 Water level below minimum water level when put into operation.

v Submerge the pump deeper.

Error code 3 Sensor is dirty. v Clean the sensor.

Error code 4 Time is exceeded. v Place the pump in water within the

countdown.

Pump does not start, or stops suddenly during operation

Thermal switch has turned the pump off because of overheating.

v Clean the suction opening. Observe

the max. media temperature (35 °C).

Pumping without electricity. v Check fuses and electrical plug

connections.

RCD has triggered (residual current). v Disconnect the pump and contact

the GARDENA Service.

Pump is running but the delivery drops suddenly

Suction opening is clogged. v Clean the suction opening with

a water jet.

Hose is clogged. v Remove the clog from the hose.

Pump starts and stops several times in succession

Returning water from the hose v Select the next higher switch-on

point and insert the non return valve.

Pump does not start with activated sensor field ß S1

Sensor field ß S1 was activated several times within a short time and the pump is paused.

v Wait for the break. Select the next

higher switch-on point and insert the non return valve.

the hose manually

Page 7 of the Gardena Clear Water Pump 11000 Aquasensor user manual — 8. ACCESSORIES
7ページ · クリックして拡大
7ページ

7. TECHNICAL DATA

Submersible Pump Unit Value (Art. 9034)

Value (Art. 9036)

Value (Art. 9044)

Rated power W 450 750 750

Mains voltage V (AC) 230 230 230

Mains frequency Hz 50 50 50

Max. delivery capacity l/h 11,000 17,000 20,000

Max. pressure / Max. delivery head

0.7 / 7.0 0.9 / 9.0 0.9 / 9.0

Max. submersion depth m 7 7 7

Min. / max. cut-in height mm 5 / 207 5 / 207 42 / 242

Min. / max. cut-out height mm 1 / 170 1 / 170 35 / 205

Residual water level mm 1 1 35

Dirty water with max. particle diameter (* Flat suction) mm 1* / 5 1* / 5 35

Minimum water depth for operation (approx.) mm 5 5 42

Power cable m 10 (H05RN-F)

10 (H05RN-F)

10 (H07RN-F)

Weight without cable (approx.) kg 4.0 4.7 5.0

Connection thread water outlet Inch G 1 1/2" G 1 1/2" G 1 1/2"

Connection options Inch 1" / 1 1/4" / 1 1/2" / G 1"

1 1/4" / 1 1/2" / 2" 1 1/4" / 1 1/2" / 2"

Max. media temperature °C 35 35 35

Note: The switch on / switch-off heights and the minimum water level on start-up were calculated without the height differences to be negotiated. Pump heads of approx. 1 m or more may result in longer suction times of up to 1 minute, or higher minimum water levels of up to + 5 cm. * When the feet are folded in, the values are 4 mm higher in each case.

8. ACCESSORIES

GARDENA Flat Hose Set 10 m 38 mm (1/2") hose with hose clamp. Art. 5005

GARDENA Hose Clamp For 25 mm (1") hoses via the connection nipple. Art. 7193

GARDENA Hose Clamp For 32 mm (1 1/4") hoses via the connection nipple. Art. 7194

GARDENA Hose Clamp For 38 mm (1 1/2") hoses via the connection nipple. Art. 7195

GARDENA Hose Clamp For 51 mm (2") hoses via the connection nipple. Art. 7196

GARDENA Pump Connection Set For 19 mm (3/4") hoses via the GARDENA Connection System. Art. 1752

bar / m

Page 8 of the Gardena Clear Water Pump 11000 Aquasensor user manual — 9. SERVICE / WARRANTY
8ページ · クリックして拡大
8ページ

9. SERVICE / WARRANTY

Service: Please contact the address on the back page.

  • Presentation of the receipt. Normal wear and tear of parts and components (such as blades, blade fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air filters, spark plugs), visual changes, wear parts and consumables are excluded from the warranty. This manufacturer’s warranty is limited to replacement and repair of products in accordance with the abovementioned conditions. The manufacturer’s warranty does not constitute an entitlement to lodge other claims against us as a manufacturer, such as for damages. This manufacturer’s warranty does not , of course, affect statutory and contractual warranty claims against the dealer / retailer. The manufacturer’s warranty is governed by the law of the Federal Republic of Germany. In case of a warranty claim, please return the faulty product, together with a copy of the receipt and a description of the fault, with postage paid to the service address.
  • Warranty statement: In the event of a warranty claim, no charge is levied to you for the services provided. GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer, provided that the devices have been for private use only. This manufacturer’s warranty does not apply to products acquired second hand. This warranty includes all significant defects of the product that can be proved to be material or manufacturing faults. This war ranty is fulfilled by supplying a fully functional replacement product or by repairing the faulty product sent to us free of charge; we reserve the right to choose between these options. This service is subject to the following provisions:
  • The product has been used for its intended purpose as per the recommendations in the operating instructions.
  • Neither the purchaser nor a third party has attempted to open or repair the product.
  • Only Original GARDENA replacement parts and wear parts have been used for operation.

Consumables: The impeller is a consumable and is not included in the warranty.

Gardena Clear Water Pump 11000 Aquasensorについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Gardena Clear Water Pump 11000 Aquasensorに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Gardena Clear Water Pump 11000 Aquasensor 取扱説明書(PDF)

238 ページ·8.5 MB·ポンプ·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…